Programmable Touchscreen Constant Temperature and Humidity Chamber, 100 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This chamber requires a controlled ambient temperature between +5 and 30°C and a dedicated power supply of AC 220V, 50Hz. Operation outside the specified temperature range of RT+10 to 85°C and humidity range of 80% to 95%RH may cause failure or hazard.
- Ambient Temperature Constraint: The working environment must stay within the allowed range of +5 to 30°C to maintain proper temperature control.
- Power Supply Constraint: The power supply must match the specified AC 220V, 50Hz to prevent electrical hazard.
- Transport and Positioning Constraint: The chamber must be kept upright during transport and positioning to avoid compressor damage.
- Accessibility Constraint: Air inlets, test ports, shelving, drain areas, doors, and controller surfaces must remain accessible for cleaning and maintenance.
- Protection Systems: Over-temperature, overload, over-current, fan, and compressor alarms provide protection during operation.
Position the chamber in the designated location and prepare the power supply. Verify the ambient conditions and ensure all access points are clear before operation.
Required Equipment: Lifting equipment
- Unpack and Position
Position the chamber upright and unpack using suitable lifting equipment. - Confirm Installation Space
Confirm installation space against the external dimensions of 650 x 800 x 1310 mm. - Prepare Power Supply
Prepare the specified power supply of AC 220 V, 50 Hz. - Ensure Accessibility
Ensure air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance. - Verify Ambient Conditions
Verify the ambient temperature is between +5 and 30°C.
Can the BPS-100CH constant temperature and humidity chamber control humidity below 80% RH?
No, the humidity control range of the BPS-100CH is specified as 80%RH to 95%RH. The chamber does not include dehumidification capability; for applications requiring lower humidity levels, a different model with a broader humidity range or active dehumidification should be selected.
Does the BPS-100CH chamber provide active cooling to achieve temperatures below room temperature?
No, the BPS-100CH model does not include active refrigeration. Its temperature control range is RT+10 to 85°C, meaning it can only heat above ambient temperature. For testing below ambient, a model with a refrigeration system is required.
What are the power and environmental installation requirements for the BPS-100CH humidity chamber?
The chamber requires a 220 V, 50 Hz power supply with a power consumption of 1650 W, and must be operated in an ambient environment of +5 to 30°C. Installation space should accommodate the external dimensions of 650 x 800 x 1310 mm, with adequate clearance for air inlets, service ports, and maintenance access.
The Atomfair BPS-100CH constant temperature and humidity chamber provides 100 L capacity with a temperature range of RT+10 to 85 °C and humidity control from 80% to 95% RH, using a balancing-control refrigeration system and imported 304 stainless-steel interior for laboratory incubation, cultivation, and stability testing. Its programmable color touchscreen supports up to 100 programs with 1000 segments, but the absence of refrigeration below ambient and a narrow humidity range limit its applicability for low-temperature or low-humidity protocols.
Positive
- Large program capacity for staged methods: The touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycle steps, enabling complex, repeatable environmental profiles for long-duration stability studies or multi-step incubation protocols.
- Corrosion-resistant stainless-steel chamber: The imported 304 mirror-finish stainless-steel interior facilitates repeated cleaning and maintains hygiene in pharmaceutical or biotech applications, reducing cross-contamination risk during sequential tests.
Trade-offs
- No refrigeration below ambient temperature: The CH model lacks a refrigeration function, limiting the temperature control range to RT+10 °C and preventing use for low-temperature stability tests or cold-condition simulations.
- Narrow humidity range above 80% RH: Humidity control is restricted to 80–95% RH with a ±3% RH deviation, making the chamber unsuitable for low-humidity conditioning or tests requiring precise moisture levels below 80% RH.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).