160L Stainless Steel Nitrogen CabinetResearch-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The cabinet requires a stable indoor surface, level installation, and verified door sealing to maintain a nitrogen-controlled low-humidity atmosphere. Stored items must be evenly distributed across shelves without exceeding load limits, and structural and sealing components must be protected during movement.
- Installation Surface: Install the cabinet on a stable, level indoor surface to ensure proper door sealing and nitrogen retention.
- Gas Supply: Verify a stable nitrogen gas supply before operation to maintain the required humidity control range.
- Shelf Loading: Distribute stored items evenly across the three adjustable shelves and do not exceed the stated shelf-loading capacity.
- Door Sealing: Inspect and verify door sealing after installation to prevent humidity ingress and gas loss.
- Movement Protection: Protect structural and sealing components during cabinet movement and use reinforced wooden-crate packaging for shipment.
This guide provides the necessary steps to install and operate the 160L stainless steel nitrogen cabinet. Proper installation ensures a nitrogen-controlled low-humidity atmosphere for sensitive materials.
- Inspect the Cabinet
Inspect the cabinet after delivery for any visible damage or sealing defects. - Install and Level the Cabinet
Install the cabinet on a stable indoor surface and verify it is level and the door seals properly. - Connect Utilities
Connect a stable nitrogen gas supply and confirm power connections before turning on the control system. - Load Materials
Distribute stored items evenly across the shelves, keeping the door closed during normal use.
How does the 160L stainless steel nitrogen cabinet achieve its claimed 50% reduction in nitrogen gas consumption compared to ordinary nitrogen cabinets?
The cabinet integrates a precision nitrogen-control device managed by a microcomputer intelligent control system that modulates gas flow with power-off memory. This design is explicitly stated to reduce gas consumption by about 50% compared with ordinary nitrogen cabinets, as noted in the key features. The optional electronic dehumidification module can further reduce nitrogen use when operated alongside the gas-filling unit.
Can the 160L stainless steel nitrogen cabinet be integrated with an existing laboratory nitrogen supply system or on-site nitrogen generator?
Yes, the cabinet is designed for nitrogen-assisted storage and supports optional configurations including a nitrogen generator for on-site supply and an RS485 communication interface for PC-side monitoring. The handling instructions require verification of stable gas-supply conditions before operation, indicating standard compatibility with external nitrogen sources. The optional electronic dehumidification module can also operate alongside the gas-filling unit to reduce overall nitrogen use.
What are the critical installation and safety requirements for the 160L stainless steel nitrogen cabinet to maintain low-humidity conditions?
The cabinet must be installed on a stable indoor surface with the door kept closed during normal use and items distributed evenly across the 3 adjustable shelves. Over-humidity alarm support is provided for safety monitoring, and the instructions emphasize verifying stable gas-supply conditions before operation. Users must not exceed the stated shelf-loading or application conditions, and should inspect door sealing after delivery to ensure the 1%-60% RH humidity control range can be maintained.
The 160L Stainless Steel Nitrogen Cabinet (AF-SSNC160) features SUS304 stainless steel construction and a precision nitrogen-control device that reduces gas consumption by approximately 50% compared to ordinary cabinets, making it well-suited for clean-room and sensitive material storage. Operational considerations include dependence on external nitrogen and power supplies and a humidity control range limited to 1%-60% RH.
Positive
- SUS304 Stainless Steel Construction: The cabinet body is made of SUS304 stainless steel, providing corrosion resistance and clean-room compatibility for sensitive storage environments.
- 50% Reduction in Nitrogen Consumption: The precision nitrogen-control device is designed to reduce gas consumption by approximately 50% compared to ordinary nitrogen cabinets, lowering operational costs.
Trade-offs
- Requires External Gas and Power Supply: The cabinet depends on a stable external nitrogen supply and electrical connection for operation, necessitating appropriate laboratory infrastructure.
- Humidity Range Limited to 1% RH Minimum: The humidity control range is 1%-60% RH, so it cannot achieve ultra-low humidity levels below 1% RH without additional dehumidification options.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).