Four-Sided Strong-Light Incubator, 360 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This incubator requires a level installation with adequate ventilation and an ambient temperature not exceeding 26°C when the set temperature is 10°C or below. The unit lacks humidity control and performance data are measured under no-load conditions; over-temperature self-limiting and power-off memory protect operation during faults.
- Level Installation: The chamber must be kept level to ensure proper operation and uniform temperature distribution.
- Ventilation Clearance: Adequate space around the unit is required for ventilation to prevent overheating.
- Ambient Temperature Limit: Ambient temperature must not exceed 26°C when the set temperature is 10°C or below.
- Humidity Control: The incubator does not provide humidity control; external humidification may be needed for humidity-sensitive experiments.
- Over-Temperature Protection: The unit includes over-temperature self-limiting and power-off memory to protect samples and settings during faults.
This procedure describes the initial setup and configuration of the Four-Sided Strong-Light Incubator. Follow these steps to ensure safe and correct operation.
- Position the incubator
Position the incubator on a level surface with sufficient clearance for ventilation around the unit. - Unload and position upright
Keep the unit upright during unloading and positioning to avoid damage to internal components. - Configure shelves and lighting
Confirm the selected shelf arrangement and lighting configuration before loading samples. - Set temperature and light program
Set the desired temperature and light program using the LCD programmable controller. - Verify ambient temperature constraint
If the set temperature is 10°C or below, verify that the ambient temperature does not exceed 26°C.
How does the four-sided strong-light layout affect temperature uniformity in the 360 L incubator?
The Four-Sided Strong-Light Incubator maintains a temperature uniformity of ±1°C across the 360 L chamber, as specified in the technical data. The four-sided lighting provides up to 18000 lux in 6 levels and is designed to work within the standard programmable incubation framework without compromising temperature stability. The mirror-finish stainless steel inner chamber and LCD microcomputer controller help ensure uniform conditions despite the high-intensity illumination.
What are the ambient temperature requirements for operating the Four-Sided Strong-Light Incubator at low set points?
The product specification states that when the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to ensure proper performance. Additionally, the incubator does not include humidity control, so experiments requiring precise humidity regulation may need external equipment. This constraint is critical for low-temperature applications such as seed germination or microbial preservation.
What infrastructure and handling precautions are required for installing the 360 L four-sided strong-light incubator?
The incubator weighs 205 kg and has external dimensions of 850 x 945 x 1775 mm. It requires a level surface, adequate ventilation, and a power supply of AC220V 50Hz with 1100 W input. The unit must be kept upright during transport and positioning, as shipped with reinforced packaging. Built-in features include over-temperature self-limiting and power-off memory to protect the chamber during routine use.
The Atomfair GZX360F 360 L four-sided strong-light incubator delivers programmable temperature and illumination control across 5-60°C and 0-18000 lux in 6 levels, with a mirror-finish stainless-steel interior and self-diagnostic safety features. However, operation at low setpoints (≤10°C) requires ambient temperature ≤26°C, and the unit lacks humidity control, which may constrain certain culture protocols.
Positive
- Four-sided strong-light illumination: Up to 18000 lux from four sides in 6 levels supports high-intensity plant-growth experiments and photoperiod studies, providing uniform light distribution across the 360 L chamber.
- Programmable temperature and light control: LCD microcomputer controller with programmable settings enables repeatable experimental conditions for culture, incubation, and growth tasks, with timer range 0-9999 min and power-off memory.
Trade-offs
- Ambient temperature constraint at low setpoints: When set temperature is 10°C or below, ambient temperature must not exceed 26°C, limiting placement in warmer laboratory environments without additional cooling.
- No humidity control: The incubator does not include humidity regulation, which may be a limitation for tissue culture, microbial preservation, or other applications requiring precise humidity levels.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).