Strong-Light Climate Chamber 800 L AF-GZX800S ATOMFAIR®

$8,800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

800 L three-sided strong-light climate chamber with 5-60 °C no-light control, 10-60 °C illuminated control, 0-18000 lx lighting and built-in humidification.

SKU: AF-LE-E-GZXS-0800-800S
Category:
Brands:

Three-Sided Strong-Light Climate Chamber, 800 L
Research-grade laboratory product
Product Overview

Three-Sided Strong-Light Climate Chamber, 800 L is a practical chamber for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection. It brings together 800 l of usable space, No-light mode: 5 to 60 C; illuminated mode: 10 to 60 C and 0 to 18000 lx illumination, so the chamber can keep samples in a steady, repeatable working condition.

The cabinet uses a stainless-steel working chamber, a strong-light layout and a visible observation door to support stronger cultivation conditions. The cabinet uses a stainless-steel working chamber, a cold-rolled steel exterior and a three-sided strong-light layout, with an internal working room of 680 x 1000 x 1200 mm and an external footprint of 880 x 1300 x 1860 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The strong-light series is designed for high-light cultivation and climate work that also needs built-in humidification support. The stated input power is 1500 W, and the timer range is 0 to 9999 minutes. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-GZX800S
Capacity 800 L
Temperature Control Range No-light mode: 5 to 60 C; illuminated mode: 10 to 60 C
Temperature Resolution 0.1 C
Temperature Uniformity +/- 2 C
Humidification Built-in humidification for high-temperature and high-humidity operation
Light Intensity 0 to 18000 LX
Lighting Faces 3 faces
Controller LCD microcomputer programmable controller
Chamber Material Stainless-steel working chamber
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 1500 W
Power Supply AC220 50Hz
Timer Range 0 to 9999 minutes
Internal Dimensions 680 x 1000 x 1200 mm
External Dimensions 880 x 1300 x 1860 mm
Net Weight 340 Kg
Shelves / Trays 2 shelves
Configuration Note When set temperature is 10 C or below, ambient temperature should not exceed 26 C; performance data are measured under no-load conditions at ambient temperature 20 C and ambient humidity 50%RH
Performance Features
  • Three-sided strong lighting helps deliver the higher illumination needed for strong-light cultivation. This supports repeatable plant-growth and photoperiod experiments.
  • Built-in humidification supports high-temperature and high-humidity operation. This is useful for cultivation, conditioning and biological workflows that need moisture control.
  • Programmable control of temperature and light supports repeatable experimental conditions. This supports repeatable plant-growth and photoperiod experiments.
  • Temperature alarms and protective functions help safeguard samples during longer runs. This helps protect samples and alerts operators when abnormal conditions occur.
  • Stainless-steel chamber construction supports cleaning and routine maintenance. This helps with cleaning, corrosion resistance and long-term laboratory use.
  • The larger capacity options suit heavier sample loading and broader experimental layouts. This supports more reliable day-to-day chamber use.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber level, confirm the room environment and leave enough ventilation space around the cabinet before operation. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When set temperature is 10 C or below, ambient temperature should not exceed 26 C. Performance data are measured under no-load conditions at ambient temperature 20 C and ambient humidity 50%RH. The work environment should stay within 5 to 40 C and below 90%RH. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This climate chamber requires specific ambient conditions for safe and accurate operation. The chamber must be kept level, upright during transport, and connected to a grounded AC220V 50Hz power supply.

  • Ambient Temperature and Humidity: Operate the chamber only in an environment with temperature between 5°C and 40°C and relative humidity below 90%RH.
  • Low-Temperature Setpoint: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C.
  • Leveling and Ventilation: Position the chamber on a level surface and ensure adequate ventilation space around the cabinet.
  • Transport Orientation: Keep the unit upright during unloading and positioning to prevent damage to the refrigeration system.
  • Electrical Connection: Connect the chamber to a grounded AC220V 50Hz power supply with a capacity of 1500W.

Initial setup involves positioning the chamber and connecting power. Ensure the ambient environment meets the specified conditions before operation.

Required Equipment:

  1. Inspect for Shipping Damage
    Inspect the chamber for any visible shipping damage before unpacking.
  2. Maintain Upright Orientation
    Keep the unit upright during unloading and positioning to prevent damage to the refrigeration system.
  3. Position and Ventilate
    Position the chamber on a level, stable surface with adequate ventilation clearance.
  4. Connect Power Supply
    Connect the power cord to a grounded AC220V 50Hz electrical outlet.
  5. Verify Ambient Conditions
    Verify that the ambient temperature and humidity are within the specified operating range.

Why does the illuminated mode have a higher minimum temperature (10°C) compared to the no-light mode (5°C) on the Atomfair AF-GZX800S?

The illuminated mode requires the chamber lights to be on, which generates additional heat that limits the lower end of the temperature control range. The technical specifications state no-light mode operates from 5 to 60°C, while illuminated mode operates from 10 to 60°C. This trade-off means high-light experiments cannot reach the same low temperatures as dark incubation.

What are the electrical and power supply requirements for the Atomfair AF-GZX800S climate chamber?

The chamber requires a standard AC220V 50Hz power supply with an input power of 1500 W. This is a fixed specification; no alternate voltage or frequency options are listed. Users should confirm that their laboratory electrical infrastructure can supply stable 220V/50Hz at sufficient current for the 1500 W load before installation.

What ambient temperature conditions must be maintained when operating the AF-GZX800S at low set points?

When the set temperature is 10°C or below, the ambient room temperature must not exceed 26°C to avoid compromising chamber performance. This constraint is stated in the product specifications and configuration notes. Additionally, the general work environment should stay within 5 to 40°C and below 90%RH, and performance data are measured under no-load conditions at 20°C ambient and 50%RH.

This 800 L three-sided strong-light climate chamber provides programmable temperature and light control with built-in humidification, suitable for plant growth and microbial culture; however, its ±2°C uniformity and ambient temperature restrictions when operating at low set points must be considered for precise or cool-running applications.

Positive

  • Three-sided strong-light illumination: Three-sided lighting delivers up to 18,000 lx, enabling high-light-intensity cultivation and photoperiod experiments with more uniform light distribution across the 800 L chamber.
  • Built-in humidification for high-temp/high-humidity: Integrated humidification supports high-temperature and high-humidity operation, expanding the chamber's utility for biological conditioning, microbial culture, and moisture-sensitive workflows.

Trade-offs

  • Temperature uniformity ±2°C: The specified temperature uniformity of ±2°C under no-load conditions may limit precision for thermally sensitive experiments requiring tighter spatial temperature control.
  • Ambient temperature restriction at low set points: When set temperature is 10°C or below, ambient temperature must not exceed 26°C, restricting placement in warmer laboratory environments or requiring additional climate control.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).