70 L precision constant temperature incubator with stainless-steel liner, RT+5 to 100 °C range, 0.1 °C resolution, 500 W input and PID control.

SKU: AF-LE-E-HNCI-0070-50B1
Category:
Brands:

Precision Constant Temperature Incubator, 70 L, Stainless-Steel Interior
Research-grade laboratory product
Product Overview

Precision Constant Temperature Incubator, 70 L, Stainless-Steel Interior is a practical chamber for bacterial culture, fermentation, constant-temperature experiments and laboratory incubation tasks. It brings together 70 l of usable space, RT+5 to 100 C, so the chamber can keep samples in a steady, repeatable working condition.

The series features a cleanable chamber layout, adjustable shelf spacing, a top exhaust valve for moisture removal and a silicone sealing ring that helps with insulation and noise reduction. The cabinet uses a vertical frame cabinet with high-quality cold-rolled plate forming, a powder-coated exterior, a silicone sealing ring and a top exhaust vent, with an internal working room of 350 x 450 x 450 mm and an external footprint of 485 x 610 x 732 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The series uses natural convection and precise temperature control to keep the chamber stable for routine culture and thermal test work. The stated input power is 500 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-HN70BS
Capacity 70 L
Temperature Control Range RT+5 to 100 C
Temperature Resolution 0.1 C
Temperature Fluctuation +/- 0.5 C
Controller Smart digital PID controller with timing, over-temperature alarm, deviation correction and self-tuning
Chamber Material Thickened stainless-steel inner liner
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 500 W
Power Supply AC220V 50Hz
Timer Range 0 to 9999 min
Internal Dimensions 350 x 450 x 450 mm
External Dimensions 485 x 610 x 732 mm
Net Weight 40 Kg
Shelves / Trays 2 shelves
Operating Mode Natural convection
Configuration Note BS version uses a thickened stainless-steel liner
Optional Accessories and Functions RS485/232 interface and communication software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; CO2 controller; light-intensity detection and control system
Performance Features
  • PID temperature control supports accurate setpoint management during routine incubation. This supports more stable setpoint tracking and quicker recovery after door openings.
  • Timing, over-temperature alarm, deviation correction and self-tuning improve operating safety and ease of use. This helps protect samples and alerts operators when abnormal conditions occur.
  • Natural convection provides stable temperature distribution for standard incubation tasks. This supports more reliable day-to-day chamber use.
  • Silicone sealing and a top exhaust vent help maintain insulation while releasing moisture. This supports more reliable day-to-day chamber use.
  • Powder-coated cold-rolled steel construction improves cabinet durability and appearance. This supports more reliable day-to-day chamber use.
  • The S and BS liner options support different cleaning and corrosion-resistance preferences. This supports more reliable day-to-day chamber use.
APPLICATION SCOPE: Suitable for bacterial culture, fermentation, constant-temperature experiments and laboratory incubation tasks in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Check the liner type, shelving and installation space before placing the unit. Keep the exhaust vent clear and avoid blocking the cabinet airflow path. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: The controller supports timing, over-temperature alarm, temperature-deviation correction and self-tuning functions. The optional accessories listed on this page are communication, printing, USB storage, alarm and gas-intake add-ons. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Operate the incubator on a stable, level surface with clearance for airflow and exhaust venting. Maintain ambient conditions within the specified temperature range and avoid blocking the cabinet airflow path.

  • Installation and Clearance: Verify the installation space accommodates the external footprint and allows unobstructed airflow to the exhaust vent.
  • Electrical Safety: Confirm the power supply matches the AC220V 50Hz requirement and that the unit is connected to a properly grounded outlet.
  • Over-Temperature Protection: Ensure the over-temperature alarm is functional before use to prevent sample damage from thermal runaway.

This procedure covers the safe setup, operation, and monitoring of the incubator for routine incubation tasks. Follow these steps to maintain stable temperature control and avoid operational hazards.

Required Equipment: Precision Constant Temperature Incubator AF-HN70BS, Power supply (AC220V 50Hz)

  1. Position the unit
    Place the incubator on a stable, level surface with adequate clearance around the exhaust vent and airflow paths.
  2. Connect power
    Plug the unit into a properly grounded AC220V 50Hz outlet and verify the power cord is not damaged.
  3. Set temperature
    Set the desired temperature using the PID controller, ensuring the setpoint is within the RT+5 to 100°C range.
  4. Enable safety functions
    Activate the over-temperature alarm and confirm the deviation correction and self-tuning functions are configured as needed.
  5. Load samples
    Place samples on the shelves, ensuring they do not block the internal airflow or the exhaust vent.
  6. Monitor operation
    Monitor the temperature display and alarm status periodically to ensure stable operation and early detection of anomalies.

How does the natural convection design affect temperature uniformity and recovery after door openings in the Atomfair AF-HN70BS incubator?

The natural convection mode provides stable temperature distribution for standard incubation tasks, but recovery after door openings relies on the smart digital PID controller, which supports quicker setpoint recovery and deviation correction. The unit has a temperature fluctuation of ±0.5°C and a resolution of 0.1°C, ensuring repeatable conditions for routine culture and thermal testing.

Can the Atomfair AF-HN70BS incubator be integrated with external monitoring or CO2 control systems?

Yes, the incubator supports optional RS485/232 interface and communication software for external monitoring, as well as an optional CO2 inlet and CO2 controller for controlled-atmosphere applications. These add-ons are listed as optional accessories and must be specified at the time of order or configuration.

What are the power supply and installation requirements for the Atomfair AF-HN70BS incubator?

The incubator requires a single-phase AC220V 50Hz power supply with an input power of 500 W. The unit has an external footprint of 485 x 610 x 732 mm and weighs 40 kg. Keep the top exhaust vent clear and avoid blocking the cabinet airflow path during installation to ensure proper ventilation and temperature stability.

The AF-HN70BS 70 L precision constant temperature incubator uses natural convection and a PID controller with self-tuning to maintain ±0.5 °C fluctuation from RT+5 to 100 °C, with a thickened stainless-steel liner for corrosion resistance in routine bacterial culture and fermentation tasks.

Positive

  • Thickened stainless-steel liner: The BS version uses a thickened stainless-steel inner liner that improves corrosion resistance and cleanability for routine biological culture and constant-temperature experiments.
  • PID controller with self-tuning: The smart digital PID controller includes self-tuning, deviation correction, and over-temperature alarm, enabling stable setpoint tracking and faster recovery after door openings.

Trade-offs

  • Natural convection limits uniformity: Natural convection provides stable temperature distribution for standard incubation but may exhibit slower thermal equilibration and less uniform airflow compared to forced-convection designs, affecting high-throughput or sensitive applications.
  • AC220V 50Hz power requirement: The unit requires AC220V 50Hz power supply, which may necessitate a step-down transformer or voltage converter in regions with 110V or 60Hz mains, adding infrastructure cost and space considerations.