Precision Constant Temperature Incubator, 70 L, Stainless-Steel Interior
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
Operate the incubator on a stable, level surface with clearance for airflow and exhaust venting. Maintain ambient conditions within the specified temperature range and avoid blocking the cabinet airflow path.
- Installation and Clearance: Verify the installation space accommodates the external footprint and allows unobstructed airflow to the exhaust vent.
- Electrical Safety: Confirm the power supply matches the AC220V 50Hz requirement and that the unit is connected to a properly grounded outlet.
- Over-Temperature Protection: Ensure the over-temperature alarm is functional before use to prevent sample damage from thermal runaway.
This procedure covers the safe setup, operation, and monitoring of the incubator for routine incubation tasks. Follow these steps to maintain stable temperature control and avoid operational hazards.
Required Equipment: Precision Constant Temperature Incubator AF-HN70BS, Power supply (AC220V 50Hz)
- Position the unit
Place the incubator on a stable, level surface with adequate clearance around the exhaust vent and airflow paths. - Connect power
Plug the unit into a properly grounded AC220V 50Hz outlet and verify the power cord is not damaged. - Set temperature
Set the desired temperature using the PID controller, ensuring the setpoint is within the RT+5 to 100°C range. - Enable safety functions
Activate the over-temperature alarm and confirm the deviation correction and self-tuning functions are configured as needed. - Load samples
Place samples on the shelves, ensuring they do not block the internal airflow or the exhaust vent. - Monitor operation
Monitor the temperature display and alarm status periodically to ensure stable operation and early detection of anomalies.
How does the natural convection design affect temperature uniformity and recovery after door openings in the Atomfair AF-HN70BS incubator?
The natural convection mode provides stable temperature distribution for standard incubation tasks, but recovery after door openings relies on the smart digital PID controller, which supports quicker setpoint recovery and deviation correction. The unit has a temperature fluctuation of ±0.5°C and a resolution of 0.1°C, ensuring repeatable conditions for routine culture and thermal testing.
Can the Atomfair AF-HN70BS incubator be integrated with external monitoring or CO2 control systems?
Yes, the incubator supports optional RS485/232 interface and communication software for external monitoring, as well as an optional CO2 inlet and CO2 controller for controlled-atmosphere applications. These add-ons are listed as optional accessories and must be specified at the time of order or configuration.
What are the power supply and installation requirements for the Atomfair AF-HN70BS incubator?
The incubator requires a single-phase AC220V 50Hz power supply with an input power of 500 W. The unit has an external footprint of 485 x 610 x 732 mm and weighs 40 kg. Keep the top exhaust vent clear and avoid blocking the cabinet airflow path during installation to ensure proper ventilation and temperature stability.
The AF-HN70BS 70 L precision constant temperature incubator uses natural convection and a PID controller with self-tuning to maintain ±0.5 °C fluctuation from RT+5 to 100 °C, with a thickened stainless-steel liner for corrosion resistance in routine bacterial culture and fermentation tasks.
Positive
- Thickened stainless-steel liner: The BS version uses a thickened stainless-steel inner liner that improves corrosion resistance and cleanability for routine biological culture and constant-temperature experiments.
- PID controller with self-tuning: The smart digital PID controller includes self-tuning, deviation correction, and over-temperature alarm, enabling stable setpoint tracking and faster recovery after door openings.
Trade-offs
- Natural convection limits uniformity: Natural convection provides stable temperature distribution for standard incubation but may exhibit slower thermal equilibration and less uniform airflow compared to forced-convection designs, affecting high-throughput or sensitive applications.
- AC220V 50Hz power requirement: The unit requires AC220V 50Hz power supply, which may necessitate a step-down transformer or voltage converter in regions with 110V or 60Hz mains, adding infrastructure cost and space considerations.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).