Sintered Titanium and Porous Titanium Foam Sheet, 50 µm Filtration Rating, 200 × 200 × 5 mm, 30 PPI, 1 Piece
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For filtration accuracy, dimensional confirmation, material compatibility or custom configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
This document identifies the product-specific constraints for handling, integrating, and cleaning the sintered porous titanium sheet. These constraints must be respected to prevent structural damage or contamination during laboratory or industrial service.
- Surface Protection: Protect the porous surface from crushing and contamination before and during installation.
- Process Compatibility Review: Confirm media compatibility, operating pressure, temperature, target flow, and dimensional tolerance before installation.
- Thermal Operating Limit: Do not exceed the recommended service temperature of 300°C during continuous operation.
- Cleaning Procedure Selection: Select backflushing, steam, ultrasonic, or compatible chemical cleaning according to the process medium and operating procedure.
- Machining Integration: Use cutting, welding, or basic machining methods compatible with titanium during assembly integration.
These steps describe safe handling, installation, and cleaning of the sintered porous titanium sheet. Follow them in sequence to preserve the porous structure and confirm process compatibility.
- Inspect the received sheet
Inspect the received sheet for surface damage, contamination, blocked porosity, or dimensional deviation before installation. - Protect the porous structure
Protect the porous surface from crushing and contamination during all handling and mounting operations. - Verify assembly compatibility
Confirm media compatibility, operating pressure, temperature, target flow, and dimensional tolerance against the intended process conditions. - Match structural and filtration ratings
Review the PPI value and the micrometre filtration rating together when matching the sheet to the filtration assembly. - Install the sheet
Install the sheet into the assembly without applying concentrated point loads to the porous face. - Clean after service
Clean the porous structure using backflushing, steam, ultrasonic, or compatible chemical procedures according to the process medium.
What is the relationship between the 30 PPI (pores per inch) and the 50 µm filtration rating in this sintered titanium foam sheet?
The 30 PPI describes the cellular structure density—approximately 0.85 mm cell spacing—while the 50 µm filtration rating indicates the particle size the sheet is designed to retain. These are separate parameters: PPI influences flow characteristics and mechanical strength, whereas the filtration rating defines the size of particles captured. Both values should be reviewed together when matching the sheet to a specific separation application, as stated in the product configuration note.
What are the recommended cleaning methods for this sintered porous titanium foam sheet to ensure long-term reuse?
The sheet can be cleaned using backflushing, steam, ultrasonic, or compatible chemical procedures, depending on the process medium and operating procedure. The porous surface should be protected from crushing and contamination during cleaning. The titanium construction supports these methods due to its corrosion resistance and thermal stability up to ≤300°C, as specified in the handling and cleaning section.
What is the maximum operating temperature for this 50 µm titanium foam sheet, and how does it affect its filtration performance?
The recommended service temperature is ≤300°C. The titanium-based porous structure provides thermal stability within this range, preserving the 35–45% porosity and interconnected pore paths. Operating above 300°C may compromise the material's integrity and filtration performance, as noted in the technical specifications.
This 200 × 200 × 5 mm sintered porous titanium sheet combines a 50 µm filtration rating with a 30 PPI interconnected pore structure (35–45% porosity, ~0.85 mm cell spacing) for separation, flow distribution, and porous-electrode trials. Its operational envelope is defined by a ≤300°C service temperature and mandatory media-compatibility review before installation.
Positive
- Interconnected 35–45% porous titanium network: The 30 PPI structure with about 0.85 mm cell spacing forms interconnected through-pore paths, providing low flow resistance and stable separation for solid-liquid, gas-solid, and gas-liquid filtration.
- Corrosion-resistant and cleanable metallic media: The titanium-based structure offers corrosion resistance and thermal stability in compatible media, and can be reused after backflushing, steam, ultrasonic, or compatible chemical cleaning.
Trade-offs
- Service temperature limited to 300°C: Recommended service temperature is ≤300°C; media compatibility, operating pressure, target flow, and dimensional tolerance must all be reviewed before installation.
- Porous surface needs crush and contamination protection: The porous surface must be protected from crushing and contamination during handling, and the cleaning method must be matched to the process medium and operating procedure.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).