Sintered Titanium Foam Sheet 30μm 30 PPI 10mm ATOMFAIR®

$150.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade sintered titanium foam sheet with 30 μm filtration, 30 PPI pores, 120 × 120 × 10 mm size and 35–45% porosity for filtration trials. Order now.

Sintered Titanium and Porous Titanium Foam Sheet, 30 µm Filtration Rating, 120 × 120 × 10 mm, 30 PPI, 1 Piece
Research-grade laboratory product
Product Overview

This sintered porous titanium foam sheet combines a 30 µm filtration rating with a 30 PPI cellular structure in a 120 × 120 × 10 mm format. Its interconnected titanium framework supports solid-liquid, gas-solid and gas-liquid separation while preserving open pathways for flow.

Made from titanium or titanium-alloy powder through forming and high-vacuum sintering, the sheet contains interconnected passages with 35–45% porosity and about 0.85 mm cell spacing. Its estimated bulk density is 2.48–2.93 g/cm³. The metallic porous structure offers low flow resistance, corrosion resistance, heat tolerance, cleanability and reuse in compatible process conditions.

Supplied as one 120 × 120 × 10 mm sheet, this product fits laboratory trials and engineered filtration assemblies used in water treatment, chemical and petrochemical processing, pharmaceutical and food clarification, gas purification, catalyst recovery, oil filtration, seawater-treatment pretreatment, porous-electrode development, flow distribution, acoustic damping and thermal-management studies. Media compatibility, operating pressure, temperature, target flow and dimensional tolerance should be reviewed before quotation or installation.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-T30-E1030
Material Titanium and titanium alloy
Product Form Sintered porous titanium / porous titanium foam sheet
Manufacturing Process Powder forming and high-vacuum sintering
Filtration Rating 30 µm
Sheet Size 120 × 120 × 10 mm
Thickness 10 mm
Pore Density 30 PPI
Approximate Cell Spacing 0.85 mm
Porosity 35–45%
Open-Pore / Through-Pore Structure Interconnected porous flow paths
Bulk Density Estimate 2.48–2.93 g/cm³ (derived from 35–45% porosity and 4.51 g/cm³ dense titanium)
Relative Air Permeability 5 × 10^-4 L/(cm²·min·Pa)
General Filtration Range 0.45–100 µm
General Pore-Size Range 2.5–160 µm
Air Permeability Range 1.5–800 m³/(h·m²·kPa)
Recommended Service Temperature ≤300°C
Package Quantity 1 piece
Performance Features
  • 30 µm filtration precision paired with a 30 PPI porous-cell structure.
  • 120 × 120 × 10 mm sheet supplied as one piece.
  • Cell spacing is approximately 0.85 mm for the 30 PPI structure.
  • A 35–45% porosity range leaves interconnected paths for liquids and gases.
  • Uniform pore distribution supports stable separation and controlled filtration.
  • Titanium-based porous structure provides corrosion resistance and thermal stability in compatible media.
  • Metallic construction can support cutting, welding and basic machining for assembly integration.
  • Cleaning options include backflushing, steam, ultrasonic and compatible chemical procedures.
Application Scope

This 30 µm, 30 PPI titanium sheet can be evaluated in porous-metal filtration and separation workflows that fit a 120 × 120 × 10 mm envelope. Relevant fields include pharmaceutical and chemical process filtration, water-treatment prefiltration, food and beverage clarification, oil and solvent filtration, gas and steam purification, catalyst recovery, desalination pretreatment, porous electrodes, flow distribution, acoustic control, thermal transfer and laboratory materials research.

PROCUREMENT CHECK: Confirm filtration rating, PPI, sheet dimensions, material grade, target flow, operating pressure, temperature and media compatibility before quotation.
CONFIGURATION NOTE: PPI describes the cellular structure, while the micrometre value describes filtration precision. Review both values together when matching the sheet to an assembly.
HANDLING & CLEANING: Protect the porous surface from crushing and contamination. Choose backflushing, steam, ultrasonic or chemical cleaning according to the process medium and operating procedure.
RFQ NOTE: Custom dimensions are available upon consultation. Include the required length, width, thickness, PPI, filtration rating and quantity when requesting dimensional review.
LABORATORY PROCUREMENT SUPPORT
For filtration accuracy, dimensional confirmation, material compatibility or custom configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This document defines handling, cleaning, and compatibility constraints for the sintered porous titanium foam sheet. The porous structure must be protected from crushing and contamination, and cleaning must match the process medium and operating procedure.

  • Handling protection: Protect the porous surface from crushing and contamination during handling, installation, and cleaning.
  • Cleaning method selection: Choose backflushing, steam, ultrasonic, or compatible chemical cleaning according to the process medium and operating procedure.
  • Compatibility review: Review media compatibility, operating pressure, temperature, target flow, and dimensional tolerance before quotation or installation.
  • Service temperature limit: Do not exceed the recommended 300°C service temperature for the sheet.

This procedure covers handling, installation, and cleaning of the sintered porous titanium foam sheet. Follow these actions to avoid crushing or contaminating the porous structure and to maintain compatible service conditions.

Required Equipment: Backflushing system, Steam cleaning equipment, Ultrasonic cleaner

  1. Confirm compatibility before installation
    Confirm filtration rating, PPI, sheet dimensions, material grade, target flow, operating pressure, temperature, and media compatibility before quotation or installation.
  2. Protect the porous structure
    Protect the porous surface from crushing and contamination while transferring and positioning the sheet in the assembly.
  3. Select the cleaning method
    Choose backflushing, steam, ultrasonic, or compatible chemical cleaning according to the process medium and operating procedure.
  4. Verify conditions before return to service
    Confirm media compatibility and operating conditions before returning the cleaned sheet to service.

How does the combination of a 30 µm filtration rating and a 30 PPI cellular structure affect flow resistance versus filtration efficiency?

The sheet achieves a balance between fine filtration (30 µm) and open flow paths due to its interconnected porous structure with 35–45% porosity and approximately 0.85 mm cell spacing. Its relative air permeability is specified as 5×10⁻⁴ L/(cm²·min·Pa), indicating measurable flow capacity while maintaining the stated filtration precision.

Can this sintered titanium foam sheet be welded or machined for integration into existing assemblies?

Yes. The metallic construction supports cutting welding and basic machining for assembly integration as stated in the performance features. However dimensional tolerance should be reviewed before installation to ensure proper fit within the intended assembly envelope.

What cleaning methods are recommended for this porous titanium sheet to avoid clogging or damage?

Recommended cleaning methods include backflushing steam ultrasonic and compatible chemical procedures chosen according to the process medium and operating procedure. The porous surface must be protected from crushing and contamination during handling to maintain its structural integrity.

This 120 × 120 × 10 mm sintered porous titanium sheet combines a 30 µm filtration rating with a 30 PPI open-cell structure, 35–45% porosity, and a recommended service temperature of ≤300°C, making it suitable for laboratory filtration, gas purification, and porous-electrode studies. The porous titanium surface supports cleaning and limited machining, but media compatibility and surface protection must be reviewed before installation.

Positive

  • Dual filtration and cellular rating: The 30 µm filtration rating is paired with a 30 PPI cellular structure, giving ~0.85 mm cell spacing and 35–45% interconnected porosity that supports stable separation with low flow resistance.
  • Corrosion-resistant and cleanable titanium: The sintered titanium/titanium-alloy framework is rated for service up to 300°C and can be cleaned by backflushing, steam, ultrasonic, or compatible chemical procedures; cutting, welding, and basic machining are also supported for assembly integration.

Trade-offs

  • Service temperature capped at 300°C: Recommended service temperature is limited to ≤300°C, and media compatibility, operating pressure, target flow, and dimensional tolerance must be reviewed before installation.
  • Porous surface requires crush protection: The open porous structure must be protected from crushing and contamination, and the cleaning method must be matched to the process medium and operating procedure.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Specification

30μm, 120×120×10mm, 30PPI, 1pcs