Sintered Titanium and Porous Titanium Foam Sheet, 10 µm Filtration Rating, 200 × 200 × 5 mm, 30 PPI, 1 Piece
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For filtration accuracy, dimensional confirmation, material compatibility or custom configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The sheet must be protected from crushing and contamination to preserve its porous structure and filtration integrity. Cleaning methods include backflushing, steam, ultrasonic, or compatible chemical procedures depending on the process medium.
- Temperature Limit: Recommended service temperature does not exceed 300°C.
- Media Compatibility: Media compatibility, operating pressure, and temperature must be reviewed before installation.
- Structural Integrity: The metallic structure supports cutting, welding, and basic machining for assembly integration.
Protect the porous surface from physical damage and contamination during handling and installation. Select a cleaning method appropriate for the process medium and operating procedure.
Required Equipment: Backflushing system, Steam cleaning equipment, Ultrasonic bath
- Inspect the sheet
Inspect the sheet for visible damage or contamination before handling. - Handle with care
Handle the sheet by its edges to avoid crushing the porous surface. - Select cleaning method
Select a cleaning method based on the process medium and operating procedure. - Apply cleaning procedure
Apply backflushing, steam, ultrasonic, or compatible chemical cleaning as selected. - Rinse and dry
Rinse the sheet with compatible solvent and dry it before reuse.
How does the 30 PPI pore density affect the 10 µm filtration rating on this sintered titanium foam sheet?
The 30 PPI (pores per inch) defines the cellular structure with a cell spacing of approximately 0.85 mm, while the 10 µm filtration rating is achieved through the interconnected porous framework formed by powder sintering. The 35–45% porosity and open-pore structure enable precise separation at 10 µm while maintaining low flow resistance. Per the product description, PPI describes the cellular structure and the micrometre value describes filtration precision, so both parameters must be evaluated together for the intended application.
What is the maximum service temperature for this sintered titanium foam sheet, and what media compatibility constraints apply?
The recommended service temperature is ≤300°C, as stated in the technical specifications. The sheet is made from titanium and titanium alloy, providing corrosion resistance and thermal stability in compatible media. However, the product description explicitly advises reviewing media compatibility, operating pressure, temperature, target flow, and dimensional tolerance before quotation or installation to ensure safe and effective use.
What cleaning methods are recommended for this porous titanium foam sheet to avoid damage and maintain filtration performance?
The product description lists backflushing, steam, ultrasonic, and compatible chemical procedures as cleaning options. The porous surface must be protected from crushing and contamination to preserve its integrity. The choice of cleaning method should be based on the process medium and operating procedure, as stated in the handling and cleaning notes.
This 200 × 200 × 5 mm sintered porous titanium sheet provides 10 µm filtration precision within a 30 PPI cellular structure and 35–45% interconnected porosity. Its corrosion-resistant, machinable metallic matrix suits filtration, flow distribution, and porous-electrode research, but installation requires confirmation of media compatibility, operating pressure, target flow, and dimensional tolerances within a ≤300 °C service envelope.
Positive
- Interconnected porosity with 10 µm filtration: The 35–45% interconnected through-pore structure supports liquid and gas flow paths while the 30 PPI cellular framework with approximately 0.85 mm cell spacing maintains the stated 10 µm filtration rating.
- Machinable corrosion-resistant metallic matrix: The titanium-based porous construction provides corrosion resistance and thermal stability in compatible media, and can support cutting, welding, and basic machining for assembly integration.
Trade-offs
- Service temperature limited to 300 °C: Although the metallic structure has heat tolerance, the recommended service temperature is ≤300 °C, so process streams above this ceiling require alternative media or system redesign.
- Surface sensitive to crushing and contamination: The porous surface must be protected from crushing and contamination during handling and installation, and media compatibility, operating pressure, target flow, and dimensional tolerance must be reviewed before deployment.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).