|
Sintered Titanium and Porous Titanium Foam Sheet, 10 µm Filtration Rating, 100 × 200 × 5 mm, 30 PPI, 1 Piece
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For filtration accuracy, dimensional confirmation, material compatibility or custom configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The sheet must be protected from crushing and contamination to preserve its porous structure and filtration integrity. Cleaning methods include backflushing, steam, ultrasonic, or compatible chemical procedures depending on the process medium.
- Service Temperature Limit: Recommended service temperature does not exceed 300°C.
- Media Compatibility Requirement: Media compatibility, operating pressure, temperature, and target flow must be reviewed before quotation or installation.
- Structural Integrity Warning: The porous surface must be protected from crushing forces during handling and assembly.
Inspect the sheet for visible damage before installation to ensure filtration performance. Select a cleaning method based on the process medium and operating procedure to maintain open pore pathways.
Required Equipment: Backflushing system, Steam cleaning equipment, Ultrasonic bath
- Inspect the sheet
Inspect the sheet for visible damage, contamination, or deformation before installation. - Install the sheet
Install the sheet into the filtration assembly, ensuring the porous surface is not crushed or deformed by clamping forces. - Select cleaning method
Select a cleaning method—backflushing, steam, ultrasonic, or chemical—based on the process medium and operating procedure. - Perform cleaning
Perform the chosen cleaning procedure to remove trapped particulates without damaging the porous structure. - Verify cleanliness
Verify that the sheet is free of residual contaminants before reinstallation or storage.
How does the 30 PPI pore density relate to the 10 µm filtration rating in this sintered titanium foam sheet?
The 30 PPI (pores per inch) describes the cellular structure and cell spacing (approximately 0.85 mm), while the 10 µm value specifies the filtration precision. Both parameters must be evaluated together when matching the sheet to an assembly, as PPI influences flow distribution and permeability, while the filtration rating determines particle retention size.
What are the temperature and media compatibility limits for this porous titanium foam sheet?
The recommended service temperature is ≤300°C. Media compatibility must be reviewed before installation, as the titanium-based structure provides corrosion resistance in compatible media, but specific process conditions (pressure, temperature, chemical exposure) should be confirmed for each application.
What cleaning methods are recommended for this sintered porous titanium sheet?
Cleaning options include backflushing, steam, ultrasonic, and compatible chemical procedures. The porous surface must be protected from crushing and contamination during handling and cleaning, and the choice of method should depend on the process medium and operating procedure.
The AF-T30-B0510 sintered porous titanium foam sheet combines a 10 µm filtration rating with a 30 PPI cellular structure and 35–45% interconnected porosity, making it viable for lab-scale filtration, purification, catalyst recovery, and porous-electrode studies within recommended temperature and compatibility limits.
Positive
- Interconnected 35–45% porous titanium structure: The 30 PPI sheet provides interconnected through-pore flow paths with 35–45% porosity and approximately 0.85 mm cell spacing, supporting solid-liquid, gas-solid, and gas-liquid separation with low flow resistance.
- Corrosion-resistant, heat-tolerant, cleanable material: The titanium/titanium alloy construction tolerates recommended service temperatures up to 300°C and supports backflushing, steam, ultrasonic, and compatible chemical cleaning for reuse in suitable process media.
Trade-offs
- Process compatibility must be verified before installation: Media compatibility, operating pressure, temperature, target flow, and dimensional tolerance must be confirmed before quotation or installation because the metal structure's corrosion resistance and thermal stability are media- and condition-dependent.
- Porous surface requires crush and contamination protection: Handling guidance explicitly requires protecting the porous surface from crushing and contamination; the cleaning method must be selected according to the process medium and operating procedure.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).







