Programmable Light Incubator 1500 L, AF-MPB1500, ATOMFAIR®

$34,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

1500 L programmable light incubator with 0-40000 lx illumination, 10-50 °C with lighting, 0.1 °C resolution, four shelves and 30-segment control. Order now.

SKU: AF-LE-E-M2HP-1500-BP15
Category:
Brands:

High-Intensity Programmable Light Incubator, 1500 L
Research-grade laboratory product
Product Overview

High-Intensity Programmable Light Incubator, 1500 L is a high-intensity programmable light incubator or artificial climate chamber designed for plant growth, agricultural cultivation, seedling studies and climate-controlled biological test programs. This configuration offers 1500 l working volume, With lighting: 10 to 50 C; without lighting: 0 to 50 C, 0 to 40000 lx, six-step adjustable lighting, mirror-finish stainless-steel chamber interior and programmable controller for temperature, light, humidity and time steps for controlled laboratory operation.

The series is described around stronger illumination, long-duration running and programmable environmental control, with multiple lighting forms available from single-side to partition-style arrangements. The chamber uses dual imported compressors with automatic alternating operation together with infrared CO2 sensor package available for atmosphere-control configurations, 4 shelves, helping the unit fit continuous cultivation, incubation, climate simulation or stability workflows where repeatable environmental control matters.

This family is appropriate when higher light levels and longer cultivation cycles are more important than compact footprint, especially in plant growth and advanced climate-simulation programs. Installation planning can be based on the external size of 1570 x 1475 x 2050 mm with power requirement 4300 W. Optional functions such as rs485 or usb communication and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; partition lighting system allow the chamber to be configured for data logging, alarm notification, atmosphere support and application-specific monitoring.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-MPB1500
Capacity 1500 L
Temperature Control Range With lighting: 10 to 50 C; without lighting: 0 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function No active humidity control stated for this configuration
Humidity Deviation +/- 5%RH to 7%RH
Lighting Configuration 0 to 40000 LX, six-step adjustable; partition lighting, two layers; single-side, three-side or partition lighting depending on model volume and chamber form
Controller programmable controller for temperature, light, humidity and time steps
Chamber Material mirror-finish stainless-steel chamber interior
Power / Input 4300 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration infrared CO2 sensor package available for atmosphere-control configurations
Cooling System dual imported compressors with automatic alternating operation
Internal Dimensions 1550 x 590 x 1650 mm
External Dimensions 1570 x 1475 x 2050 mm
Shelves / Light Decks 4 shelves
Program Function temperature, humidity, light intensity and time can be set independently across 30 programmed segments
Optional Accessories and Functions RS485 or USB communication and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; partition lighting system
Performance Features
  • High-intensity lighting configurations deliver a broader chamber-illumination range for demanding plant-growth protocols. This supports plant-growth or climate-chamber work that depends on repeatable illumination conditions.
  • Programmable control simplifies complex day-night or staged environmental cycles. This supports more reliable day-to-day laboratory use in plant growth, agricultural cultivation, seedling studies and climate-controlled biological test programs.
  • Imported compressors and long-running refrigeration strategy support stable operation during extended cultivation programs. This supports dependable low-temperature performance and long-duration running stability.
  • Wireless alarm, fault display and over-limit protection help maintain sample safety in unattended runs. This helps protect samples and alert operators when abnormal conditions appear.
  • Optional CO2 monitoring and control can be added where plant-growth atmosphere support is needed. This helps expand the chamber for advanced cultivation programs that require atmosphere management.
  • Partition lighting options improve use of vertical space while keeping cultivation layers independently illuminated. This supports plant-growth or climate-chamber work that depends on repeatable illumination conditions.
APPLICATION SCOPE: Suitable for plant growth, agricultural cultivation, seedling studies and climate-controlled biological test programs in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 1570 x 1475 x 2050 mm, prepare the stated power supply, and keep air inlets, exhaust paths, shelves, ports, doors and control interfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select the required controller, lighting, humidity, communication and optional accessory configuration before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed with shipping details.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a stable power supply of AC 220 V, 50 Hz and must be operated in an ambient temperature range of 5°C to 30°C. The unit must be placed with adequate clearance for air intake and exhaust to prevent overheating and ensure proper cooling.

  • Electrical Safety: The electrical system includes over-limit protection and fault display to prevent damage from power surges or component failures.
  • Environmental Installation: Installation space must accommodate the external dimensions of 1570 x 1475 x 2050 mm with accessible ports and ventilation paths.
  • Transport and Handling: The packed chamber must remain upright during transport and use suitable lifting equipment to avoid damage to compressors and internal components.
  • Chamber Maintenance: The mirror-finish stainless-steel interior should be cleaned regularly to maintain light reflectivity and prevent contamination of samples.

Follow these steps to safely install, program, and start the incubator for plant growth or climate-controlled experiments. Each step ensures proper operation and sample safety.

Required Equipment: Lifting equipment

  1. Inspect Installation Area
    Confirm the installation space meets the external dimensions of 1570 x 1475 x 2050 mm and has access to AC 220 V, 50 Hz power supply.
  2. Unpack the Chamber
    Inspect the reinforced packaging for damage, then carefully unpack the chamber using suitable lifting equipment and keep it upright.
  3. Position and Connect
    Place the chamber in the prepared location, ensure air inlets and exhaust paths are clear, and connect the power cord to the specified outlet.
  4. Program Environmental Cycles
    Use the programmable controller to set temperature, light intensity, and time steps for up to 30 segments as required by the experiment.
  5. Configure Safety Alarms
    Enable the over-limit protection and wireless alarm system to monitor for abnormal conditions during unattended operation.

How does the high-intensity lighting (up to 40000 lx) affect the temperature control range and uniformity in the 1500 L Atomfair AF-MPB1500 chamber?

With lighting active, the temperature control range is 10 to 50 °C; without lighting, the range extends from 0 to 50 °C. Temperature uniformity across the chamber is ±1 °C regardless of lighting state. The six-step adjustable lighting system adds heat load, narrowing the lower end of the controlled temperature range by 10 °C.

Does the AF-MPB1500 standard configuration include active humidity control for plant growth or climate simulation?

No, the standard configuration does not include active humidity control. The specified humidity deviation of ±5 to 7 %RH reflects passive environmental conditions, not active regulation. For active humidity control, an optional configuration or alternative model selection is required.

What are the power and installation requirements for the 1500 L dual-compressor incubator?

The chamber requires a 4300 W, AC 220 V / 50 Hz dedicated power supply and an installation footprint of at least 1570 × 1475 × 2050 mm (external dimensions). The dual imported compressors alternate automatically to support long-duration running stability. The working environment must be +5 to 30 °C, and adequate space for air intake, exhaust, and access to shelves, ports, and control interfaces should be maintained.

The Atomfair AF-MPB1500 1500 L programmable light incubator provides a 0–40000 lx six-step adjustable lighting system and dual-imported-compressor refrigeration for long-duration plant growth and climate-simulation protocols, with a mirror-finish stainless-steel interior and 30-segment programmable control of temperature, light, humidity, and time. Its 4300 W power draw and 1570 x 1475 x 2050 mm footprint require dedicated infrastructure, and the absence of active humidity control in this configuration limits its use in humidity-critical applications.

Positive

  • High-intensity six-step adjustable lighting: The 0 to 40000 lx range with six-step adjustability supports demanding plant-growth and climate-simulation protocols requiring repeatable illumination conditions, with partition lighting options for independent vertical-layer control.
  • Dual-imported-compressor alternating operation: The dual-imported-compressor system with automatic alternating operation supports stable long-duration running, which is critical for continuous cultivation and extended climate-controlled biological test programs.

Trade-offs

  • No active humidity control: This configuration does not include active humidity control; humidity deviation is stated as +/-5%RH to 7%RH, which may not meet protocols requiring tight humidity regulation.
  • High power and space requirements: The unit requires a 4300 W power supply (AC 220 V, 50 Hz) and an external footprint of 1570 x 1475 x 2050 mm, demanding dedicated electrical infrastructure and significant lab floor space.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).