Programmable LED Light Incubator, 150 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator must be installed in a controlled environment with ambient temperature between 5 and 30 °C and connected to a dedicated 1500 W, 220 V/50 Hz power supply. The unit must remain upright during transport and have adequate clearance for air circulation and maintenance access.
- Power Specification: Use only a dedicated AC 220 V, 50 Hz power outlet rated for 1500 W to avoid electrical hazards.
- Ambient Temperature: Operate the incubator only when the room temperature is within +5 to 30 °C to maintain specified temperature control performance.
- Installation Space: Provide an area that accommodates the external dimensions of 690 x 800 x 1410 mm and allows unobstructed access to air vents, power cord, and control panel.
- Transport Orientation: Always keep the incubator upright during handling and use appropriate lifting equipment to prevent compressor damage.
Unpack and position the incubator in the prepared installation space, ensuring upright orientation. Connect power, configure the controller program, and load samples while maintaining clear airflow paths.
Required Equipment: Lifting equipment
- Unpack and Position
Unpack the incubator while keeping the chamber upright and use suitable lifting equipment to move it to the installation location. - Clear Clearance
Place the incubator on a level surface with at least the required clearance for air inlets, exhaust, and door operation. - Connect Power
Connect the incubator to a dedicated AC 220 V, 50 Hz power supply with a minimum capacity of 1500 W. - Configure Controller
Configure the programmable controller with the desired multi-segment temperature, light intensity, and time settings for the cultivation program. - Load Samples and Verify Environment
Load samples onto the three shelves ensuring airflow remains unobstructed, and confirm the ambient temperature is between 5 and 30 °C before starting continuous operation.
How does the lighting configuration affect the temperature control range in the Atomfair AF-M2B0150 incubator?
The temperature control range is 10 to 50 °C with lighting and 0 to 50 °C without lighting. This difference arises because the LED lighting generates heat, raising the minimum achievable temperature when active. The unit uses two imported compressors with alternating long-duration operation to maintain stability across both ranges.
Can the Atomfair AF-M2B0150 incubator be equipped with CO2 control for plant growth studies?
Yes, optional accessories include a CO2 inlet and an infrared CO2 controller. When the optional atmosphere-control package is selected, the chamber uses an infrared CO2 sensor to regulate and monitor CO2 levels, supporting specialized plant-growth workflows that require precise atmospheric composition control.
What are the installation space and power requirements for the 150 L Atomfair programmable LED light incubator?
The external dimensions are 690 x 800 x 1410 mm, requiring a level surface with accessible air inlets, exhaust paths, and ports. Power requirement is 1500 W at AC 220 V, 50 Hz, and the working environment must be +5 to 30 °C. Confirm installation space and power supply before ordering, as freight and the chamber body are separate items.
The Atomfair AF-M2B0150 150L programmable LED light incubator provides long-duration operational stability via dual alternating compressors, multi-segment programmable control of temperature, humidity, light, and time, and optional CO2 and communication interfaces, but lacks active humidity control and requires specific power (220V, 50Hz, 1500W) and installation space (690x800x1410 mm) planning.
Positive
- Dual alternating compressor design: Two imported compressors automatically alternate to support continuous long-duration operation, enhancing reliability for extended cultivation, incubation, or stability-testing workflows.
- Programmable multi-segment controller: Allows independent setting of temperature, humidity, light intensity, and time across up to 30 segments, enabling precise simulation of environmental cycles for plant growth, tissue culture, or BOD applications.
Trade-offs
- No active humidity control: The stated configuration does not include active humidity control; only a deviation range of ±5–7% RH is provided, which may limit applications requiring precise humidity regulation.
- Power and installation requirements: Requires AC 220V, 50Hz, 1500W power supply and a clear installation space of 690x800x1410 mm with accessible air inlets and exhaust paths, mandating pre-installation planning.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).