Programmable LED Light Incubator, 1000 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This chamber must be connected to a power supply matching AC 220 V, 50 Hz with sufficient capacity for its 2800 W input and installed in a space that accommodates its external dimensions with accessible service points. Operate the unit only within the specified +5 to 30 C working environment and keep it upright during transport and positioning to protect the refrigeration system.
- Power Supply Constraint: Confirm that the available electrical supply matches the stated AC 220 V, 50 Hz input before connecting the chamber.
- Installation Space Constraint: Position the chamber in an area that accommodates its 1410 x 890 x 1950 mm external dimensions and keeps air inlets, exhaust paths, shelves, ports, doors and control interfaces accessible for cleaning and maintenance.
- Transport Orientation Constraint: Keep the packed chamber upright and use suitable lifting equipment to reduce movement and impact during transport.
- Working Environment Constraint: Operate the chamber only within the specified +5 to 30 C working environment to maintain reliable temperature control.
- Configuration Constraint: Select the required controller, lighting, humidity, communication and optional accessory configuration before ordering because the displayed amount refers to the chamber body only.
Install the chamber in a suitable laboratory space with access to air circulation paths and connect it to the specified AC power supply before programming. Configure the multi-segment controller for temperature, humidity, light intensity and time settings prior to loading samples.
Required Equipment: suitable lifting equipment
- Inspect delivery
Inspect the delivered chamber for transport damage while keeping it upright and using suitable lifting equipment. - Position chamber
Position the chamber in an installation space that accommodates its external dimensions and keeps air inlets, exhaust paths, ports, doors and control interfaces accessible. - Connect power
Connect the chamber to a power supply matching AC 220 V, 50 Hz with capacity for its 2800 W input. - Set program
Set the desired multi-segment temperature, humidity, light intensity and time programs on the programmable controller. - Load samples
Place samples on the three shelves according to your cultivation protocol after setting the program. - Monitor operation
Monitor operation through the programmable controller and any optional alarm or communication interfaces.
How does the alternating dual-compressor system enable long-duration continuous operation in the 1000 L LED incubator, and what temperature stability does it provide?
The 1000 L LED incubator uses two imported compressors with an alternating long-duration operation design, automatically cycling between compressors to support continuous chamber operation without single-unit fatigue. This design, combined with mirror-finish stainless-steel interior and circulation-air layout, maintains temperature fluctuation and uniformity within ±1°C across the 0–50°C range (without lighting) or 10–50°C (with lighting).
What optional communication and environmental control interfaces are available for the 1000 L programmable LED incubator to integrate with laboratory data systems?
The incubator offers optional RS485 or RS232 communication interface with software for data logging, USB data storage, and an embedded printer for trend review. Additionally, a wireless alarm system, CO2 inlet, and an infrared CO2 controller can be added to support atmosphere-controlled plant-growth workflows, though these are not included in the base configuration.
What are the external dimensions and power requirements that must be considered for installation of the 1000 L LED incubator?
The incubator measures 1410 x 890 x 1950 mm externally and requires a 2800 W power supply at AC 220 V, 50 Hz. Installation planning must also account for a working environment of +5 to 30°C and ensure adequate clearance for air inlets, exhaust paths, and door access to maintain stable long-duration operation.
The Atomfair Programmable LED Light Incubator (1000 L) features a dual-compressor alternating design for continuous long-duration operation and a 30-segment programmable controller for precise environmental control, but lacks active humidity regulation and requires 2800 W power with substantial installation space.
Positive
- Alternating dual-compressor design: Two imported compressors automatically alternate to support continuous chamber operation, enabling dependable low-temperature performance and long-duration running stability.
- Multi-segment programmable controller: The controller supports up to 30 independent program segments with time settings from 1 minute to 99 hours 59 minutes, allowing precise environmental tracking for incubation and cultivation workflows.
Trade-offs
- No active humidity control: This configuration does not include active humidity control; humidity deviation is stated as ±5%RH to 7%RH, which may limit applications requiring precise humidity regulation.
- High power and space requirements: The unit requires 2800 W at 220 V 50 Hz and external dimensions of 1410 x 890 x 1950 mm, necessitating dedicated electrical infrastructure and adequate installation space.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).