Programmable Climate Chamber 800 L 0-50°C ATOMFAIR®

$23,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 800 L climate chamber with 0-50 °C control, 50-90%RH humidity, 0-30000 lx lighting, 0.1 °C resolution and 30 programmable segments. Order now.

SKU: AF-LE-E-M2HP-0800-HP80
Category:
Brands:

High-Intensity Programmable Artificial Climate Chamber, 800 L
Research-grade laboratory product
Product Overview

High-Intensity Programmable Artificial Climate Chamber, 800 L is a high-intensity programmable light incubator or artificial climate chamber designed for plant growth, agricultural cultivation, seedling studies and climate-controlled biological test programs. This configuration offers 800 l working volume, With lighting: 10 to 50 C; without lighting: 0 to 50 C, 50%rh to 90%rh humidity capability, 0 to 30000 lx, six-step adjustable lighting, mirror-finish stainless-steel chamber interior and programmable controller for temperature, light, humidity and time steps for controlled laboratory operation.

The series is described around stronger illumination, long-duration running and programmable environmental control, with multiple lighting forms available from single-side to partition-style arrangements. The chamber uses dual imported compressors with automatic alternating operation together with infrared CO2 sensor package available for atmosphere-control configurations, 3 shelves, helping the unit fit continuous cultivation, incubation, climate simulation or stability workflows where repeatable environmental control matters.

This family is appropriate when higher light levels and longer cultivation cycles are more important than compact footprint, especially in plant growth and advanced climate-simulation programs. Installation planning can be based on the external size of 1475 x 890 x 1780 mm with power requirement 2800 W. Optional functions such as rs485 or usb communication and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; partition lighting system allow the chamber to be configured for data logging, alarm notification, atmosphere support and application-specific monitoring.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-MPH0800
Capacity 800 L
Temperature Control Range With lighting: 10 to 50 C; without lighting: 0 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function 50%RH to 90%RH
Humidity Deviation +/- 5%RH to 7%RH
Lighting Configuration 0 to 30000 LX, six-step adjustable; partition lighting, two layers; single-side, three-side or partition lighting depending on model volume and chamber form
Controller programmable controller for temperature, light, humidity and time steps
Chamber Material mirror-finish stainless-steel chamber interior
Power / Input 2800 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration infrared CO2 sensor package available for atmosphere-control configurations
Cooling System dual imported compressors with automatic alternating operation
Internal Dimensions 800 x 590 x 1650 mm
External Dimensions 1475 x 890 x 1780 mm
Shelves / Light Decks 3 shelves
Program Function temperature, humidity, light intensity and time can be set independently across 30 programmed segments
Optional Accessories and Functions RS485 or USB communication and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; partition lighting system
Performance Features
  • High-intensity lighting configurations deliver a broader chamber-illumination range for demanding plant-growth protocols. This supports plant-growth or climate-chamber work that depends on repeatable illumination conditions.
  • Programmable control simplifies complex day-night or staged environmental cycles. This supports more reliable day-to-day laboratory use in plant growth, agricultural cultivation, seedling studies and climate-controlled biological test programs.
  • Imported compressors and long-running refrigeration strategy support stable operation during extended cultivation programs. This supports dependable low-temperature performance and long-duration running stability.
  • Wireless alarm, fault display and over-limit protection help maintain sample safety in unattended runs. This helps protect samples and alert operators when abnormal conditions appear.
  • Optional CO2 monitoring and control can be added where plant-growth atmosphere support is needed. This helps expand the chamber for advanced cultivation programs that require atmosphere management.
  • Partition lighting options improve use of vertical space while keeping cultivation layers independently illuminated. This supports plant-growth or climate-chamber work that depends on repeatable illumination conditions.
APPLICATION SCOPE: Suitable for plant growth, agricultural cultivation, seedling studies and climate-controlled biological test programs in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 1475 x 890 x 1780 mm, prepare the stated power supply, and keep air inlets, exhaust paths, shelves, ports, doors and control interfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select the required controller, lighting, humidity, communication and optional accessory configuration before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed with shipping details.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber requires a dedicated AC 220V 50Hz power supply with a minimum 2800W capacity and an ambient temperature range of +5 to 30°C. Installation space must accommodate the external dimensions of 1475 x 890 x 1780 mm with adequate clearance for air circulation and maintenance access.

  • Transport and Handling: The packed chamber must be kept upright and moved using suitable lifting equipment to prevent damage.
  • Power Supply: A dedicated AC 220V, 50Hz power source with sufficient capacity for the 2800W load is required.
  • Working Environment: The chamber must be installed in an environment with ambient temperature between +5 and 30°C.
  • Installation Clearance: Adequate space must be maintained around the chamber for air inlets, exhaust paths, and service access.

This procedure describes the unpacking, positioning, power connection, and maintenance access verification steps for the chamber. Follow these steps to ensure proper installation and safe operation.

Required Equipment: suitable lifting equipment

  1. Move Chamber to Installation Site
    Use suitable lifting equipment to move the packed chamber to the installation site, keeping it upright at all times.
  2. Confirm Installation Space
    Confirm that the installation space accommodates the external dimensions of 1475 x 890 x 1780 mm with adequate clearance for air circulation.
  3. Connect Power Supply
    Prepare the power supply by connecting the chamber to a dedicated AC 220V 50Hz source capable of supporting the 2800W load.
  4. Verify Accessibility
    Verify that air inlets, exhaust paths, shelves, ports, doors, and control interfaces remain accessible for cleaning and maintenance.

What are the temperature uniformity and humidity deviation specifications for the Atomfair AF-MPH0800 800 L climate chamber?

The chamber maintains temperature fluctuation/uniformity of ±1°C across its operating range. Humidity deviation is specified at ±5%RH to ±7%RH over the 50%RH to 90%RH humidity range. These tolerances are stated in the technical specifications for the model AF-MPH0800.

Can the Atomfair AF-MPH0800 climate chamber be configured with CO2 monitoring and control for plant growth applications?

Yes, the chamber supports an optional infrared CO2 sensor package and CO2 inlet for atmosphere-control configurations. This allows advanced cultivation programs requiring CO2 management. The controller can integrate these options for programmed environmental cycles.

What are the power supply and installation space requirements for the 800 L artificial climate chamber?

The chamber requires a 2800 W power supply at AC 220 V, 50 Hz. External dimensions are 1475 x 890 x 1780 mm, so installation space must accommodate these measurements plus access for air inlets, exhaust paths, and maintenance. The working environment should be +5 to 30°C.

The Atomfair AF-MPH0800 is an 800L artificial climate chamber with programmable control of temperature (0-50°C), humidity (50-90%RH), and light intensity (0-30000 lx), featuring dual compressors for extended operation and optional CO2 monitoring, designed for plant growth, seedling studies, and climate-controlled biological programs.

Positive

  • High-intensity programmable lighting: The chamber delivers 0-30000 lx with six-step adjustable and partition lighting options, enabling repeatable illumination for demanding plant-growth protocols.
  • Dual compressor alternating operation: Dual imported compressors with automatic alternating support stable long-duration running, critical for extended cultivation and climate-simulation programs.

Trade-offs

  • Infrastructure power and environment requirements: Requires 2800W at AC 220V, 50Hz and an ambient operating range of +5 to 30°C, necessitating dedicated electrical and HVAC planning in lab installation.
  • Humidity control precision tolerance: Humidity deviation is specified as ±5% to 7%RH, which may limit applications requiring tighter humidity stability, especially near the upper or lower setpoints.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).