Programmable Climate Chamber 360 L 5-60°C ATOMFAIR®

$2,850.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 360 L programmable climate chamber with 5-60°C no-light and 10-60°C illuminated temperature control, 50-90%RH humidity, and 0-10000 lux lighting.

SKU: AF-LE-E-QHXT-0360-360T
Category:
Brands:

Programmable Climate Chamber, 360 L
Research-grade laboratory product
Product Overview

Programmable Climate Chamber, 360 L is a practical chamber for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection. It brings together 360 l of usable space, No-light mode: 5 to 60 C; illuminated mode: 10 to 60 C, 50%rh to 90%rh humidity control and 0 to 10000 lux (6 levels) illumination, so the chamber can keep samples in a steady, repeatable working condition.

The cabinet uses top lighting, a visible glass inner door and a cleanable stainless-steel chamber to support both observation and repeatable environmental control. The cabinet uses a mirror-finish stainless-steel inner chamber, a tempered-glass inner door, a cold-rolled steel exterior and top lighting, with an internal working room of 600 x 600 x 1000 mm and an external footprint of 835 x 755 x 1695 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The series is designed to simulate natural climate conditions with programmable temperature, light and humidity control for plant and biological experiments. The stated input power is 900 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-QHX360T
Capacity 360 L
Temperature Control Range No-light mode: 5 to 60 C; illuminated mode: 10 to 60 C
Temperature Resolution 0.1 C
Temperature Uniformity +/- 2 C
Humidity Range 50%RH to 90%RH
Humidity Deviation +/- 8%RH
Light Intensity 0 to 10000 Lux (6 levels)
Lighting Faces 2 faces
Controller LCD microcomputer programmable controller
Chamber Material Mirror-finish stainless-steel inner chamber
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 900 W
Power Supply AC220V 50Hz
Timer Range 0 to 9999 min
Internal Dimensions 600 x 600 x 1000 mm
External Dimensions 835 x 755 x 1695 mm
Net Weight 129.5 Kg
Shelves / Trays 2 shelves
Program Function Programmable temperature, light, humidity and time control
Configuration Note When set temperature is 10 C or below, ambient temperature should not exceed 26 C; when temperature setpoint is above 40 C, humidity setpoint should generally not exceed 80%
Optional Accessories and Functions RS485/232 interface and communication software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; CO2 controller; light-intensity detection and control system
Performance Features
  • Programmable control of temperature, light, humidity and time supports simulated natural-climate workflows. This is useful for cultivation, conditioning and biological workflows that need moisture control.
  • The top lighting structure is useful for germination and plant-growth experiments. This supports repeatable plant-growth and photoperiod experiments.
  • Self-diagnosis, over-temperature self-limiting and power-off memory help protect the chamber and the samples. This helps preserve operation settings after power interruptions.
  • The embedded screen and menu-style operation make multi-parameter control easy to follow. This supports more reliable day-to-day chamber use.
  • Mirror-finish stainless-steel surfaces and a glass inner door support visibility and cleaning. This helps with cleaning, corrosion resistance and long-term laboratory use.
  • Multiple optional interfaces and atmosphere accessories extend the chamber to more advanced test methods. This supports more reliable day-to-day chamber use.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber away from direct heat sources, maintain stable room temperature and confirm the selected accessory package before installation. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When the set temperature is 10 C or below, ambient temperature should not exceed 26 C. When the temperature setpoint is above 40 C, humidity setpoints should generally not exceed 80%. Performance notes are based on no-load testing at 20 C and 50%RH ambient humidity. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber must be operated within specified ambient temperature limits to maintain performance. When set temperature is 10°C or below, ambient temperature should not exceed 26°C, and when setpoint is above 40°C, humidity setpoints should generally not exceed 80%RH.

  • Ambient Temperature Constraint: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to ensure proper operation.
  • Humidity Setpoint Constraint: When the temperature setpoint exceeds 40°C, the humidity setpoint should generally not exceed 80%RH to avoid performance issues.
  • Power Supply Requirement: The chamber requires a grounded AC220V 50Hz power supply with a 900 W input capacity.
  • Transport and Positioning: Keep the unit upright during unloading and positioning, and maintain stable room temperature away from direct heat sources.

Position the chamber in a stable environment away from direct heat sources and connect to the appropriate power supply. Set the programmable parameters and allow the chamber to stabilize before introducing samples.

Required Equipment: LCD microcomputer programmable controller, Chamber body

  1. Position the chamber
    Position the chamber upright on a level surface away from direct heat sources and ensure adequate ventilation.
  2. Connect to power supply
    Connect the chamber to a grounded AC220V 50Hz power supply and verify that the ambient room temperature is stable and within the required range.
  3. Set control parameters
    Set the desired temperature, humidity, and light intensity parameters using the LCD microcomputer programmable controller.
  4. Allow chamber stabilization
    Allow the chamber to reach the setpoint and stabilize for at least 30 minutes before placing samples inside.
  5. Monitor chamber conditions
    Monitor chamber conditions periodically and adjust parameters as needed to maintain the required experimental environment.

What are the temperature and humidity performance limits of the Atomfair AF-QHX360T programmable climate chamber?

The AF-QHX360T provides a no-light temperature range of 5 to 60 °C and an illuminated range of 10 to 60 °C, with 0.1 °C resolution and ±2 °C uniformity. Humidity is controllable from 50%RH to 90%RH with ±8%RH deviation. These figures are based on no-load testing at 20 °C and 50%RH ambient humidity.

Can the chamber maintain high humidity when the temperature setpoint is above 40 °C?

The chamber is not specified for high-humidity operation above 40 °C; the configuration note states that when the temperature setpoint is above 40 °C, humidity setpoints should generally not exceed 80%RH. Additionally, when the set temperature is 10 °C or below, ambient temperature should not exceed 26 °C.

What power supply and installation conditions are required for the 360 L programmable climate chamber?

The chamber requires AC220V 50Hz power with a 900 W input rating. It should be kept away from direct heat sources in a stable room-temperature environment, and the unit must remain upright during unloading and positioning. The external footprint is 835 x 755 x 1695 mm and net weight is 129.5 kg, so floor loading and access space should be confirmed before installation.

The Atomfair AF-QHX360T is a 360 L programmable climate chamber with top lighting, temperature range 5-60°C (no-light) or 10-60°C (illuminated), humidity 50-90%RH, and light up to 10000 lux. Its stainless-steel interior and programmable controller support plant growth and biological studies. However, ambient temperature must be ≤26°C when set temperature is ≤10°C, and humidity should not exceed 80% at setpoints above 40°C.

Positive

  • Programmable multi-parameter control: The LCD microcomputer controller enables programmable temperature, light, humidity, and time settings, allowing users to simulate natural climate conditions for cultivation, germination, and tissue culture experiments.
  • Top lighting for uniform illumination: Top-mounted lighting with 6 intensity levels up to 10000 lux supports repeatable photoperiod experiments and even light distribution across the 360 L chamber, beneficial for plant growth and seed germination studies.

Trade-offs

  • ambient temperature constraint at low setpoint: When the chamber is set to 10°C or below, the ambient laboratory temperature must not exceed 26°C to maintain performance, which may require additional climate control in warm facilities.
  • Humidity limitation at high temperature: At set temperatures above 40°C, the humidity setpoint should generally not exceed 80%RH, restricting simultaneous high-temperature and high-humidity operation for certain protocols.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).