Programmable Artificial Climate Chamber, 150 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This unit requires a stable AC 220 V, 50 Hz power supply and an ambient temperature between 5 °C and 30 °C. The chamber must be installed on a level surface with sufficient clearance for air intake and exhaust, and operated with the door closed to maintain controlled conditions.
- Power Supply Requirements: The chamber requires a 1750 W power supply at AC 220 V, 50 Hz.
- Ambient Operating Conditions: The working environment must be maintained between +5 °C and +30 °C.
- Installation Clearance: Air inlets and exhaust paths must remain unobstructed for proper airflow.
- Transport and Handling: The chamber must be kept upright during transport and moved using suitable lifting equipment.
- Temperature and Humidity Limits: When lighting is on, temperature is limited to 10–50 °C; without lighting, 0–50 °C; humidity range is 50–90 %RH.
Confirm installation space and prepare the required power supply before unpacking. After placement, program the controller with the desired temperature, humidity, light, and time segments for the cultivation workflow.
Required Equipment:
- Confirm Installation Space
Confirm that the installation site meets the external dimensions (690 x 800 x 1410 mm) and ambient temperature range (5–30 °C). - Connect Power Supply
Connect the chamber to a dedicated AC 220 V, 50 Hz power outlet rated for 1750 W. - Program the Controller
Set the temperature, humidity, and light intensity for each program segment using the programmable controller. - Verify Chamber Readiness
Verify that the door is closed and the air inlets are unobstructed before starting the run. - Start the Program
Start the program and monitor the display for alarms or fault signals during operation.
What is the temperature range when operating with lighting versus without lighting on the Atomfair Programmable Artificial Climate Chamber 150 L?
With lighting active, the temperature control range is 10 to 50°C; without lighting, it extends to 0 to 50°C. This difference arises from the heat generated by the LED lighting system. In both modes, the chamber maintains a temperature fluctuation and uniformity of ±1°C.
What power supply and environmental conditions are required for the Atomfair AF-M2H0150 climate chamber?
The chamber requires AC 220V, 50 Hz with a power input of 1750 W. The permissible working environment is +5 to 30°C. Installation space must accommodate external dimensions of 690 x 800 x 1410 mm. Optional accessories such as CO2 control, communication interfaces, and data logging must be specified before ordering.
How does the dual-compressor alternating design support long-duration continuous operation in the Atomfair 150 L climate chamber?
The chamber uses two imported compressors that automatically alternate operation to distribute mechanical wear and prolong service life. This design enables dependable low-temperature performance and stable running over weeks or months, reducing the risk of single-point failure during extended cultivation or incubation programs.
Programmable Artificial Climate Chamber, 150 L offers dual alternating compressors for continuous long-duration operation, programmable multi-segment control of temperature, humidity, light, and time, and optional CO2 and communication functions, but requires a controlled ambient environment (5–30°C) and has moderate humidity precision (±5–7% RH).
Positive
- Dual alternating compressors for long-duration running: Two imported compressors automatically alternate to support continuous chamber operation, ensuring dependable low-temperature performance and stability over weeks or months.
- Programmable multi-segment environmental control: The controller allows independent setting of temperature, humidity, light intensity and time across 30 program segments, enabling precise environmental tracking for incubation, cultivation and stability studies.
Trade-offs
- Moderate humidity precision: Humidity deviation is specified as ±5% to ±7% RH, which may not meet the requirements of experiments demanding tight humidity control below ±3% RH.
- Ambient temperature sensitivity: The chamber's working environment is limited to +5 to 30°C; performance, especially temperature stability, may degrade outside this range, necessitating a climate-controlled laboratory space.