Programmable Artificial Climate Chamber AF-M2H1500 ATOMFAIR®

$38,600.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

1500 L programmable LED climate chamber with 0-50°C temperature control, 50-90%RH humidity, 0-55000 lx lighting and 30-segment programming. Order now.

SKU: AF-LE-E-M2LP-1500-H150
Category:
Brands:

Programmable Artificial Climate Chamber, 1500 L
Research-grade laboratory product
Product Overview

Programmable Artificial Climate Chamber, 1500 L is a programmable LED light incubator or artificial climate chamber designed for plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation. This configuration offers 1500 l working volume, With lighting: 10 to 50 C; without lighting: 0 to 50 C, 50%rh to 90%rh humidity capability, 0 to 55000 lx, six-step adjustable lighting, mirror-finish stainless-steel chamber interior and programmable controller with multi-segment temperature, humidity, light and time setting for controlled laboratory operation.

This long-duration programmable family is positioned for cultivation programs that require stable running over weeks or months, using imported compressors, mirror-finish chamber construction and a circulation-air layout that limits direct draft on plants. The chamber uses two imported compressors with alternating long-duration operation design together with infrared CO2 sensor when the optional atmosphere-control package is selected, 4 shelves, helping the unit fit continuous cultivation, incubation, climate simulation or stability workflows where repeatable environmental control matters.

The family is designed for cultivation work that benefits from adjustable lighting levels, programmable climate changes and optional alarm, communication or CO2 functions without exposing pricing or source-notes in the public page. Installation planning can be based on the external size of 1570 x 1475 x 2050 mm with power requirement 4500 W. Optional functions such as rs485 or 232 communication interface and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; lighting control system allow the chamber to be configured for data logging, alarm notification, atmosphere support and application-specific monitoring.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-M2H1500
Capacity 1500 L
Temperature Control Range With lighting: 10 to 50 C; without lighting: 0 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function 50%RH to 90%RH
Humidity Deviation +/- 5%RH to 7%RH
Lighting Configuration 0 to 55000 LX, six-step adjustable; daylight-lamp partition lighting; family lighting configurations range from top-mounted LED lighting to three-side and partition lighting systems
Controller programmable controller with multi-segment temperature, humidity, light and time setting
Chamber Material mirror-finish stainless-steel chamber interior
Power / Input 4500 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration infrared CO2 sensor when the optional atmosphere-control package is selected
Cooling System two imported compressors with alternating long-duration operation design
Internal Dimensions 1550 x 590 x 1650 mm
External Dimensions 1570 x 1475 x 2050 mm
Shelves / Light Decks 4 shelves
Program Function 30 program segments, each with time setting from 1 minute to 99 hours 59 minutes
Optional Accessories and Functions RS485 or 232 communication interface and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; lighting control system
Performance Features
  • Long-duration running design uses imported compressors that automatically alternate to support continuous chamber operation. This supports dependable low-temperature performance and long-duration running stability.
  • Programmable control can set temperature, humidity, light intensity and time independently in multi-step processes. This helps improve environmental tracking for incubation, cultivation and stability-study workflows.
  • LED lighting is available in multiple chamber layouts, from top-mounted lighting to three-side or partition-style designs. This supports plant-growth or climate-chamber work that depends on repeatable illumination conditions.
  • Wireless alarm and fault-display functions help operators respond quickly when abnormal conditions appear. This helps protect samples and alert operators when abnormal conditions appear.
  • Optional CO2 inlet and infrared CO2 controller support specialized plant-growth workflows. This helps operators review setpoints, trends and alarms more efficiently during routine operation.
  • RS485 or 232 communication, USB export and printer options help create operation records and trend review. This supports more reliable day-to-day laboratory use in plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, insect culture, BOD work and climate-controlled biological cultivation in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 1570 x 1475 x 2050 mm, prepare the stated power supply, and keep air inlets, exhaust paths, shelves, ports, doors and control interfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select the required controller, lighting, humidity, communication and optional accessory configuration before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed with shipping details.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Operate the chamber within an ambient temperature range of +5 to 30°C and supply AC 220V, 50 Hz power with adequate capacity for 4500 W. Keep the chamber upright during transport and positioning, and maintain clear access to air inlets, exhaust paths, and control interfaces for proper operation.

  • Electrical Supply: Connect the chamber to a dedicated AC 220V, 50 Hz power supply rated for at least 4500 W to avoid circuit overload.
  • Ambient Temperature: Operate the chamber only when the ambient temperature is between +5°C and 30°C to ensure proper cooling system performance.
  • Transport Orientation: Transport and store the chamber in an upright orientation to prevent compressor oil migration and damage.
  • Ventilation: Keep the air inlets and exhaust paths unobstructed to maintain proper airflow and prevent overheating.

Install the chamber in a suitable location with adequate space and power supply, then configure the controller for the desired environmental parameters. Follow these steps to ensure safe setup and reliable operation.

Required Equipment: Lifting equipment

  1. Verify Installation Space
    Confirm that the installation space accommodates the external dimensions of 1570 x 1475 x 2050 mm.
  2. Prepare Power Supply
    Prepare a dedicated AC 220V, 50 Hz power supply capable of supporting the 4500 W load.
  3. Position the Chamber
    Unpack the chamber while keeping it upright and use lifting equipment to move it into the installation space.
  4. Ensure Accessibility
    Ensure that air inlets, exhaust paths, shelves, ports, doors, and control interfaces remain accessible for cleaning and maintenance.
  5. Configure Controller
    Program the multi-segment controller with the desired temperature, humidity, light intensity, and time settings.
  6. Connect Optional Accessories
    Connect optional communication interfaces, CO2 inlet, or alarm system as required for the application.
  7. Perform System Check
    Verify that all parameters are set correctly and that the chamber operates within specified tolerances before loading samples.

What is the actual temperature range of the 1500 L artificial climate chamber when lighting is active compared to when it is off?

With lighting active, the temperature range is 10 to 50 °C; without lighting, the range extends from 0 to 50 °C. Temperature resolution is 0.1 °C with a fluctuation/uniformity of ±1 °C. These ranges are explicitly specified for the 1500 L model and reflect the impact of lighting heat on chamber performance.

Can the chamber be integrated with external data logging or alarm systems for remote monitoring?

Yes, the 1500 L chamber supports optional RS485 or 232 communication interface and software, USB data storage, an embedded printer, and a wireless alarm system. These options enable remote data logging, trend review, and immediate fault notification without requiring aftermarket modifications.

What are the critical installation space and power requirements for this 1500 L chamber?

Installation requires a minimum external footprint of 1570 x 1475 x 2050 mm and a dedicated 4500 W power supply at AC 220 V, 50 Hz. The working environment must be maintained between +5 and 30 °C. Keeping air inlets, exhaust paths, and doors accessible is essential for proper operation and maintenance.

This 1500 L programmable climate chamber features dual alternating compressors for long-duration continuous operation and multi-segment control of temperature, humidity, and light. The 4500 W power requirement and +/-5-7%RH humidity deviation are practical constraints for lab infrastructure planning.

Positive

  • Dual alternating compressor design: Two imported compressors automatically alternate to support continuous long-duration operation, reducing wear and improving reliability for extended cultivation runs.
  • Multi-segment programmable control: Independent setpoint programming for temperature, humidity, light intensity, and time in up to 30 segments allows precise replication of climate profiles for plant growth, tissue culture, and stability studies.

Trade-offs

  • High power consumption: The 4500 W input at 220 V/50 Hz requires dedicated high-current electrical infrastructure, which may not be available in all laboratory settings.
  • Humidity deviation tolerance: Specified humidity deviation of +/-5 to 7%RH limits precision for applications requiring tight humidity control, such as certain seed germination or tissue culture protocols.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).