Anti-Oxidation Nitrogen Cabinet 450L 1–60% RH ATOMFAIR®

$1,550.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

450 L anti-oxidation nitrogen cabinet with 1%-60% RH control, 900 × 600 × 1010 mm body, Honeywell sensor, 3 shelves and 0-50 L/min N2 flow. Order now.

SKU: AF-EI-E-AONC-STD0-450L
Category:
Brands:

450L Anti-Oxidation Nitrogen Cabinet

Research-grade laboratory product

Product Overview

The 450 L configuration uses a standard white cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 900 × 600 × 1010 mm, inner dimensions of 855 × 570 × 840 mm and 3 adjustable shelves.

This anti-oxidation nitrogen cabinet is designed for oxidation-sensitive and moisture-sensitive materials that benefit from a controlled low-humidity nitrogen atmosphere. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability during inspection staging, daily handling and long-term preservation.

Typical application areas include research laboratories, electronics workshops, optical part storage rooms, powder and film storage areas, technical archives and quality-control spaces that require organized nitrogen-assisted dry storage. This body type suits general laboratories, inspection rooms and organized storage areas.

The cabinet combines 1.2 mm galvanized steel cabinet with white exterior panels, tempered-glass viewing doors and magnetic sealing, Honeywell temperature and humidity sensing, fully automatic computer control, temperature and humidity display, perforated adjustable shelves and 0-50 L/min nitrogen-flow adjustment for repeatable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-AONC450
Product Family Anti-Oxidation Nitrogen Cabinet
Cabinet Body Standard white cabinet body
Nominal Capacity 450 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 900 × 600 × 1010 mm
Inner Dimensions (W × D × H) 855 × 570 × 840 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with white exterior panels and 5 mm tempered-glass viewing doors
Control Mode Fully automatic computer control
Display and Monitoring Display-based monitoring for temperature, humidity and operating status
Temperature Display Range -9°C to 99°C
Humidity Display Range 0%-99% RH
Humidity Indication Accuracy ±3% RH
Annual Sensor Drift 0.3%
Sensor Honeywell temperature and humidity sensor
Nitrogen Flow Control 0-50 L/min
Alarm Function Over-humidity alarm support
Suitable Stored Materials Oxidation-sensitive electronic components, optical parts, powders, films and laboratory materials

Key Features and Advantages

  • 1.2 mm galvanized steel cabinet construction with 5 mm tempered-glass viewing panels, magnetic door sealing and a lockable cabinet structure.
  • Honeywell temperature and humidity sensor with ±3% RH humidity indication accuracy and 0.3% annual drift.
  • Fully automatic computer control with temperature display range of -9°C to 99°C and humidity display range of 0%-99% RH.
  • Perforated adjustable shelves support orderly material staging and internal circulation.
  • Nitrogen-control arrangement with 0-50 L/min flow adjustment for controlled cabinet-atmosphere management.

Optional Items and Consultation

  • Anti-static cabinet body upgrade with ESD-compliant exterior coating for electrostatic-control environments.
  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, optical storage rooms, powder and film storage areas, technical archives and quality-control environments that require controlled nitrogen-assisted dry storage for oxidation-sensitive and moisture-sensitive materials.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This cabinet requires a stable, level installation and a regulated nitrogen gas supply to maintain a low-humidity atmosphere within 1% to 60% RH. Proper load distribution, door sealing, and periodic sensor verification are necessary to prevent moisture ingress and ensure reliable performance.

  • Gas Supply Verification: Verify that a stable nitrogen supply with adequate flow control is connected before operating the cabinet.
  • Installation Surface: Install the cabinet on a stable, level indoor surface to ensure proper door sealing and sensor accuracy.
  • Load Distribution: Distribute stored items evenly across the three shelves to avoid overloading and maintain uniform atmospheric circulation.
  • Humidity Alarm Trigger: The over-humidity alarm activates when internal humidity exceeds the configured set point, indicating a loss of atmospheric control.
  • Sensor Drift Consideration: Account for the Honeywell sensor's annual drift of 0.3% RH when setting humidity thresholds and scheduling recalibration.

This sequence covers initial installation, connection, and loading of the cabinet to establish a controlled nitrogen atmosphere. Following these steps ensures safe and effective storage of oxidation- and moisture-sensitive materials.

Required Equipment: Nitrogen gas supply with flow regulator, Level and alignment tools

  1. Inspect and Level Cabinet
    Inspect the cabinet after delivery for damage and verify that it is level and the door seals properly.
  2. Connect Utilities
    Confirm that power and nitrogen gas connections meet the cabinet's specifications and connect them securely.
  3. Set Nitrogen Flow
    Adjust the nitrogen flow rate between 0 and 50 L/min using the front-panel control to achieve the desired atmosphere conditions.
  4. Load Materials
    Distribute oxidation-sensitive materials evenly across the three adjustable shelves to maintain balanced airflow.
  5. Close and Monitor
    Close the cabinet door and monitor the temperature and humidity display until the internal conditions stabilize within the set range.

How does the 0-50 L/min nitrogen flow adjustment affect humidity stability in the 450L Anti-Oxidation Nitrogen Cabinet?

The cabinet's nitrogen flow control range of 0-50 L/min allows tuning the atmosphere replacement rate to maintain the target humidity within the 1%-60% RH control range. The Honeywell sensor provides ±3% RH indication accuracy, but achieving stable low humidity (e.g., below 10% RH) requires balancing flow rate against cabinet volume (450 L) and door-open frequency. Excessive flow increases nitrogen consumption without proportional humidity improvement, while insufficient flow may allow moisture ingress.

When is the anti-static cabinet body upgrade necessary for storing sensitive electronic components?

The standard cabinet uses 1.2 mm galvanized steel with white exterior panels, which is not inherently ESD-compliant. For electrostatic-control environments, such as semiconductor or electronics workshops handling static-sensitive devices, the anti-static cabinet body upgrade with ESD-compliant exterior coating is recommended. This optional upgrade prevents static discharge from the cabinet surface, complementing the low-humidity nitrogen atmosphere for complete oxidation and ESD protection.

What gas supply infrastructure is required for the 450L Anti-Oxidation Nitrogen Cabinet?

The cabinet requires a stable nitrogen gas supply with flow control of 0-50 L/min, typically from a compressed gas cylinder or in-house nitrogen line. The user must verify stable gas-supply conditions before operation, including proper pressure regulation and leak-free connections. For facilities without a nitrogen line, an optional nitrogen generator configuration is available to produce on-site nitrogen, eliminating cylinder handling.

The 450L Anti-Oxidation Nitrogen Cabinet (AF-AONC450) provides a controlled low-humidity nitrogen atmosphere for oxidation- and moisture-sensitive materials, using a Honeywell sensor with ±3% RH accuracy and 0.3% annual drift, and a 0-50 L/min nitrogen flow adjustment, but requires a stable gas supply and careful door sealing to maintain performance.

Positive

  • Precise humidity control with low drift: Honeywell sensor provides ±3% RH indication accuracy and only 0.3% annual drift, enabling reliable long-term monitoring of the nitrogen atmosphere for sensitive materials.
  • Adjustable nitrogen flow for atmosphere management: 0-50 L/min flow adjustment allows fine-tuning of nitrogen purge rate to match material sensitivity and usage frequency, reducing gas consumption during idle periods.

Trade-offs

  • Requires stable external nitrogen supply: Operation depends on a continuous or on-demand nitrogen source; without a generator or cylinder, the cabinet cannot maintain the low-humidity atmosphere, adding infrastructure cost and logistical planning.
  • Door seal integrity critical for performance: Magnetic sealing and tempered-glass doors must remain properly closed and undamaged; any seal degradation or improper closure will compromise humidity control and increase nitrogen consumption.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).