Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

1435 L anti-static moistureproof nitrogen cabinet with 1%-60% RH control, 1200 × 700 × 1860 mm body, 5 shelves, and dual dehumidification. Order now.

SKU: AF-EI-E-MNIC-ESD0-14L2
Category:
Brands:

1435L-4 Moistureproof Nitrogen Integrated Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 1435 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 1200 × 700 × 1860 mm, inner dimensions of 1155 × 650 × 1680 mm and 5 adjustable shelves. The 1435 L layout uses a two-door cabinet.

This moistureproof nitrogen integrated cabinet combines electronic dehumidification with nitrogen control in one storage platform for efficient low-humidity recovery. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability while lowering gas demand compared with ordinary nitrogen-only cabinet operation.

Typical application areas include research laboratories, electronics workshops, optical storage rooms, incoming-material control areas, powder and film storage spaces and quality-control environments that require low-humidity cabinet protection with efficient nitrogen management. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, an electronic dehumidification core with regenerative absorbent polymer, a precision nitrogen-control device, fully automatic switching between system modes and display-based cabinet management for dependable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-MNIC1435F-4
Product Family Moistureproof Nitrogen Integrated Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 1435 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 1200 × 700 × 1860 mm
Inner Dimensions (W × D × H) 1155 × 650 × 1680 mm
Adjustable Shelf Quantity 5
Door Configuration Two-door cabinet
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Fully automatic switching between dehumidification and nitrogen-control modes
Dehumidification System Electronic dehumidification core with regenerative absorbent polymer
Dehumidification Module Housing ABS plus flame-retardant housing
Nitrogen Control System Precision nitrogen-control device for rapid cabinet humidity reduction
Integrated Efficiency Designed to reduce nitrogen usage by more than 50% compared with ordinary nitrogen cabinets
Suitable Stored Materials Moisture-sensitive electronic parts, optical components, powders, films and laboratory materials

Key Features and Advantages

  • Integrated dual-system architecture combining an electronic dehumidification core with a precision nitrogen-control device.
  • High-performance absorbent polymer and regenerative dehumidification design for repeat-use moisture control.
  • ABS plus flame-retardant housing on the dehumidification module for durable routine cabinet operation.
  • Fully automatic switching logic between dehumidification and nitrogen-control modes according to cabinet humidity conditions.
  • Integrated cabinet design intended to reduce nitrogen usage by more than 50% compared with ordinary nitrogen cabinets.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, incoming-material control areas, powder and film storage rooms and quality-control environments that require low-humidity cabinet protection with efficient nitrogen management.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 5 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet requires a stable, level indoor surface and sealed door operation to maintain the 1-60% RH humidity range. Power and nitrogen gas connections must be confirmed before use, and stored items should be evenly distributed across the five shelves without exceeding load limits.

  • Installation Surface and Door Sealing: Install the cabinet on a stable indoor surface and verify that the door seals properly to prevent humidity leakage.
  • Utility Connections: Confirm that stable power and nitrogen gas supply are available and connected before operating the cabinet.
  • Shelf Loading: Distribute stored items evenly across the 5 adjustable shelves and do not exceed the stated shelf-loading capacity.
  • Environmental Conditions: Operate the cabinet within the humidity control range of 1-60% RH and in an electrostatic-control area if handling ESD-sensitive materials.
  • Movement and Shipping: Protect structural and sealing components during movement and use reinforced wooden-crate packaging when shipping the cabinet.

Follow these steps to safely install, connect, and load the cabinet for low-humidity storage of moisture-sensitive materials. Proper initialization ensures efficient dehumidification and nitrogen management.

Required Equipment: Leveling tool, Nitrogen gas supply, Electrical power connection

  1. Inspect Cabinet
    Inspect the cabinet after delivery for any damage and verify that all components are intact.
  2. Level Installation
    Place the cabinet on a stable indoor surface and use a leveling tool to ensure it is perfectly level, then check door sealing.
  3. Connect Utilities
    Connect the cabinet to a stable power supply and a nitrogen gas source, confirming that the gas supply is stable and leak-free.
  4. Set Humidity Parameters
    Configure the humidity control setpoint within the 1-60% RH range according to the stored materials' requirements.
  5. Load Materials
    Distribute stored items evenly across the five shelves, keeping the door closed during normal operation to maintain low humidity.

How does the integrated dehumidification system affect nitrogen consumption compared to standalone nitrogen-only cabinets?

The integrated cabinet combines electronic dehumidification with nitrogen control, reducing nitrogen usage by more than 50% compared with ordinary nitrogen-only cabinets. The regenerative absorbent polymer in the dehumidification core pre-dries the interior, lowering the nitrogen demand for rapid humidity recovery and sustained low-humidity conditions.

Can the AF-MNIC1435F-4 cabinet be used for storing ESD-sensitive components without additional anti-static measures?

Yes, the cabinet body is specifically designed for electrostatic-control areas and ESD-sensitive material handling. It features a 1.2 mm galvanized steel cabinet with anti-static exterior coating, magnetic sealing, and tempered-glass viewing doors, providing a controlled low-humidity environment suitable for moisture-sensitive electronic parts, optical components, and powders.

What infrastructure requirements are necessary for installing and operating the 1435L moistureproof nitrogen integrated cabinet?

The cabinet requires a stable indoor surface, verified gas-supply conditions (nitrogen), and standard power for the electronic dehumidification core and control system. It must be installed level with proper door sealing, and stored items should be distributed evenly across the five adjustable shelves. Optional accessories include RS485 communication interface for monitoring and an over-humidity alarm.

This 1435 L moistureproof nitrogen integrated cabinet offers an efficient dual-mode dehumidification and nitrogen control system, reducing gas consumption by over 50% while providing ESD protection for sensitive materials. Its size and utility dependencies require careful lab planning and infrastructure support.

Positive

  • Integrated dual-system reduces nitrogen consumption: Combines electronic dehumidification with nitrogen control to achieve over 50% reduction in nitrogen usage compared to conventional nitrogen-only cabinets, lowering operational gas costs.
  • Anti-static cabinet body for ESD-sensitive materials: The anti-static exterior coating and galvanized steel construction provide electrostatic discharge protection, making it suitable for handling moisture-sensitive electronic components and optical elements.

Trade-offs

  • Requires external power and nitrogen supply: The cabinet depends on a stable electrical connection and a regulated nitrogen gas source for operation, adding infrastructure requirements and potential supply chain considerations.
  • Large footprint and weight necessitate careful placement: With outer dimensions of 1200×700×1860 mm and 5 adjustable shelves, the cabinet requires a stable, level indoor surface and reinforced packaging for shipment, limiting mobility and installation flexibility.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).