Low-Temperature Incubator 100L AF-LI100-CA20 ATOMFAIR®

$4,400.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

100L low-temperature incubator with -20-65℃ control, 0.1°C resolution, ±0.5°C/±1.0°C stability, 1200 W, AC220V 50Hz, AF-LI100-CA20. In stock.

100L Low-Temperature Incubator, -20-65℃ Temperature Control Range
Research-grade laboratory product
Product Overview

100L Low-Temperature Incubator, -20-65℃ Temperature Control Range is designed for low-temperature cultivation, near-ambient incubation, sample preservation, stability testing, and temperature-controlled holding. With a nominal capacity of 100 L and a temperature range of -20-65℃, it supports controlled handling of cultures, fungal samples, microorganisms, preserved materials, and other laboratory test loads.

The cabinet layout is defined by the chamber size is 500×400×600mm, overall dimensions are 650×770×1320mm, the standard shelf setup is 3 shelves, input power is 1200 W, the power supply is AC220V 50Hz. These dimensions and electrical requirements help laboratories plan bench-side placement, floor-standing installation, teaching use, quality inspection, research sample staging, and repeated daily workflows.

Temperature performance includes 0.1°C temperature resolution, high temp ±0.5°C; low temp ±1.0°C fluctuation control, a timer range of 0 to 5999 min. The working chamber uses Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. Cooling configurations use a compressor and circulation fan with an environmentally oriented refrigerant and airflow circulation system. This construction supports regular loading, cleaning, observation, and repeated operation where stable environmental conditions are important.

Control options are shown as AF-LI100-CA20: Microcomputer liquid-crystal temperature controller. Optional functions may include an embedded printer, RS485 communication, USB data transfer, independent over-temperature alarm protection, multi-segment programmable control, and UV sterilization for applicable mold configurations. Accessory availability and custom chamber-size requirements can be checked by e-mail before ordering.

Product Specifications
Parameter Specification
Product Type Low-Temperature Incubator
Nominal Capacity 100 L
Atomfair Models AF-LI100-CA20
Temperature Range -20-65℃
Temperature Resolution 0.1°C
Temperature Fluctuation high temp ±0.5°C; low temp ±1.0°C
Input Power 1200 W
Power Supply AC220V 50Hz
Ambient Temperature +5 to 35°C
Chamber Size 500×400×600mm
Overall Dimensions 650×770×1320mm
Shelves 3 shelves
Timer 0 to 5999 min
Inner Chamber and Insulation Mirror stainless-steel inner chamber with rounded-corner transitions and removable or adjustable shelf supports for easier cleaning and loading. Cooling configurations use a compressor and circulation fan with an environmentally oriented refrigerant and airflow circulation system.
Controller Configuration AF-LI100-CA20: Microcomputer liquid-crystal temperature controller
Optional Accessories Optional embedded printer or RS485 communication interface for recording temperature changes; USB data transfer for selected configurations; Independent over-temperature alarm system where supported; Multi-segment programmable controller for selected control configurations. Some accessories may be non-stock and require lead time; email for availability and quotation.
Key Points and Advantages
  • 0.1°C temperature resolution supports finer setpoint adjustment, which is helpful for routine cultivation, preservation, and method repeatability.
  • The published fluctuation level of high temp ±0.5°C; low temp ±1.0°C helps users maintain steadier chamber conditions during day-to-day experimental cycles.
  • Sub-ambient temperature options extend the usable application range into preservation, low-temperature incubation, and stability tasks that ordinary incubators may not cover.
  • The published shelf configurations help laboratories organize flasks, bottles, trays, and routine test loads more flexibly within the available chamber volume.
  • Optional accessories can include embedded printers, RS485 communication, USB data transfer, independent over-temperature alarm support, multi-segment programmable control, and mold-series UV sterilization where applicable.
  • If a configuration needs a different chamber size or accessory package, the quotation can be adjusted by e-mail before order confirmation.
APPLICATION SCOPE: Suitable for low-temperature cultivation, near-ambient incubation, sample preservation, stability testing, and holding tasks that require cooling capability beyond a standard constant-temperature incubator.
PACKAGING: The equipment is prepared with protective inner cushioning, reinforced outer packaging, and transport-oriented structural support to help reduce vibration and handling impact during storage and delivery. Export reinforcement or other packing adjustments can be discussed when project quantity, route, or receiving conditions require it.
IMPORTANT NOTICE: Please confirm the exact configuration, installation footprint, power supply, accessory package, and delivery arrangement before ordering. If a custom chamber size is required, please contact us by e-mail for quotation and availability review.
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

This document records operating constraints applicable to the Atomfair 100L low-temperature incubator SKU AF-LE-E-LTIN-0100-1CA0. Use is permitted only after verifying electrical supply, ambient conditions, and configuration limits.

  • Electrical supply constraint: Connect the incubator only to a power supply matching AC220V 50Hz and supporting 1200W input power.
  • Ambient operating constraint: Operate the incubator only within the stated ambient temperature range of +5 to 35°C.
  • Chamber setpoint constraint: Set chamber temperature only within the published -20 to 65°C operating range.
  • Timer constraint: Set the timer only within the published 0 to 5999 min range.
  • Over-temperature alarm verification: Confirm whether independent over-temperature alarm protection is configured before relying on unattended operation.

This procedure describes initialization and safe operation of the Atomfair 100L low-temperature incubator. Follow the steps in sequence after confirming the required site infrastructure.

Required Equipment: Microcomputer liquid-crystal temperature controller

  1. Position the incubator
    Position the incubator in a location matching the +5 to 35°C ambient temperature range and allowing space for the 650×770×1320mm overall dimensions.
  2. Connect the power supply
    Connect the incubator to an AC220V 50Hz power supply compatible with the 1200W rated input power.
  3. Set temperature and timer
    Set the desired chamber temperature within the -20 to 65°C range and the timer within 0 to 5999 min using the microcomputer liquid-crystal temperature controller.
  4. Verify over-temperature alarm configuration
    Confirm whether the independent over-temperature alarm protection is configured before relying on unattended operation.
  5. Load samples
    Load samples onto the removable or adjustable shelf supports inside the mirror stainless-steel chamber.
  6. Record temperature data
    Record temperature data using the optional embedded printer, RS485, or USB interface when configured.

How tightly can the Atomfair AF-LI100-CA20 100L low-temperature incubator maintain temperature at low setpoints compared with higher setpoints?

Temperature fluctuation is specified as ±0.5°C in the high-temperature portion and ±1.0°C in the low-temperature portion across the -20 to 65°C operating range. The 0.1°C temperature resolution supports finer setpoint adjustment, while the timer range of 0 to 5999 minutes allows timed incubation or preservation cycles. These published fluctuation values help users judge suitability for routine cultivation and stability work at the selected setpoint.

Can the AF-LI100-CA20 low-temperature incubator be used for sample preservation and stability testing below ambient temperature?

Yes. The product is intended for low-temperature cultivation, near-ambient incubation, sample preservation, stability testing, and temperature-controlled holding of cultures, fungal samples, microorganisms, and preserved materials. Its compressor-based cooling configuration and -20°C lower limit extend the usable application range beyond a standard constant-temperature incubator for sub-ambient stability and preservation work.

What power supply, ambient temperature, and installation space are required for the 100L low-temperature incubator?

The incubator requires an AC220V 50Hz power supply and has an input power rating of 1200 W. It is intended for operation in ambient conditions of +5 to 35°C, with overall dimensions of 650×770×1320mm and a chamber size of 500×400×600mm. The standard configuration includes 3 shelves, so labs should confirm bench-side or floor-standing clearance, power availability, and ventilation before installation.

The 100L Low-Temperature Incubator (AF-LI100-CA20) delivers a -20 to 65°C range with 0.1°C resolution and ±0.5°C (high temp)/±1.0°C (low temp) fluctuation, enabling sub-ambient incubation and preservation tasks in a 100 L stainless-steel chamber with rounded-corner geometry for easier cleaning.

Positive

  • Sub-ambient temperature capability: The -20°C lower limit extends the usable range beyond standard incubators, supporting low-temperature cultivation, sample preservation, and stability testing in a single unit.
  • Fine 0.1°C temperature resolution: Resolution of 0.1°C combined with high-temp fluctuation of ±0.5°C and low-temp ±1.0°C aids routine repeatability for culture and preservation protocols.

Trade-offs

  • Low-temp fluctuation constraint: At low-temperature operation, fluctuation is ±1.0°C compared to ±0.5°C at high temperatures, which may reduce thermal uniformity during sub-ambient preservation or incubation.
  • 1200 W continuous power draw: The 1200 W input power and AC220V 50Hz requirement demand dedicated lab circuit planning and may increase operational heat load in small lab spaces.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).