50L Low-Temperature Incubator, -20-65℃ Temperature Control Range
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
This incubator must be installed where the ambient temperature remains within +5 to 35°C and the AC220V 50Hz power supply can support its 1100 W input rating. The stainless-steel inner chamber, rounded-corner transitions, and removable or adjustable shelf supports are specified to facilitate cleaning and loading.
- Electrical supply constraint: Connect the incubator to an AC220V 50Hz power source capable of supplying the 1100 W input rating.
- Ambient temperature constraint: Operate the incubator only in an ambient temperature between +5 and 35°C.
- Chamber access and cleaning: Use the rounded-corner mirror stainless-steel chamber and removable or adjustable shelf supports to facilitate cleaning and loading.
- Over-temperature alarm verification: Confirm whether the independent over-temperature alarm is included in the selected configuration before ordering.
Set the target chamber temperature using the microcomputer liquid-crystal temperature controller and allow the compressor and circulation fan to stabilize the chamber before loading samples. Load the samples onto the provided shelves and clean the chamber after the incubation, preservation, or holding period is complete.
Required Equipment: Microcomputer liquid-crystal temperature controller, Two provided shelves, Removable or adjustable shelf supports
- Verify installation conditions
Verify that the incubator is connected to an AC220V 50Hz power supply and placed in a +5 to 35°C ambient environment. - Set the temperature
Set the target chamber temperature on the microcomputer liquid-crystal temperature controller. - Stabilize the chamber
Wait for the chamber to reach the set temperature and stabilize before loading samples. - Load the samples
Load culture vessels, preserved materials, or stability-test samples onto the two shelves. - Set the timer
Program the timer for the intended incubation, preservation, or holding period. - Clean after use
Clean the mirror stainless-steel inner chamber and rounded-corner transitions after each use.
How tight is temperature control in the 50L low-temperature incubator at low versus high setpoints?
Control tolerance depends on setpoint: the published fluctuation is ±0.5°C in the high-temperature region and ±1.0°C in the low-temperature region, with 0.1°C temperature resolution. Low-temperature operation therefore has a wider allowable chamber swing than high-temperature operation within the -20-65℃ range.
Can the AF-LI50-CA20 be used for both microbial incubation and sub-ambient sample preservation?
Yes. The unit covers -20-65℃ and is designed for low-temperature cultivation, near-ambient incubation, sample preservation, stability testing, and holding tasks. A compressor and circulation fan provide the cooling needed for sub-ambient work, and the mirror stainless-steel chamber with rounded corners and removable/adjustable shelf supports supports routine loading and cleaning between applications.
What power, ambient temperature, and space are needed to install the 50L low-temperature incubator?
The incubator requires an AC220V 50Hz supply and 1100W input power, and its rated ambient temperature is +5 to 35°C. For placement planning, the chamber is 400×300×420mm, the overall dimensions are 660×720×930mm, and the standard configuration includes 2 shelves.
The 50L Low-Temperature Incubator (AF-LE-E-LTIN-0050-5CA0) delivers a -20 to 65°C range with 0.1°C resolution and dual-zone fluctuation (high ±0.5°C, low ±1.0°C), making it suitable for low-temperature cultivation, sample preservation, and stability testing. Its compressor-based cooling, stainless-steel chamber, and optional RS485 or printer output support routine lab workflows, though the required AC220V 50Hz supply and ambient temperature window of +5 to 35°C impose infrastructure constraints.
Positive
- Sub-ambient cooling to -20°C: The -20 to 65°C range extends usability into preservation and low-temperature incubation tasks that standard incubators cannot achieve, enabling controlled handling of cultures, fungi, and preserved materials.
- Fine temperature resolution of 0.1°C: 0.1°C setpoint resolution allows precise adjustment for routine cultivation and method repeatability, with high-temperature fluctuation at ±0.5°C and low-temperature fluctuation at ±1.0°C.
Trade-offs
- Requires AC220V 50Hz supply: The incubator requires AC220V 50Hz power at 1100 W input, which may not be compatible with standard 60 Hz lab outlets without a voltage/frequency converter, limiting deployment to regions or facilities with matching electrical infrastructure.
- Ambient temperature dependency: The specified ambient temperature range of +5 to 35°C for operation restricts placement; environments exceeding this range may degrade cooling performance or cause instability at lower setpoints.