LCD Light Incubator, 300 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator must be operated within a +5 to 30°C working environment and requires a 1450W, 220V AC power supply. Continuous operation beyond 180 hours demands proper installation conditions to maintain temperature and lighting stability.
- Temperature Mode Constraint: Temperature control range differs between no-light mode (4 to 50°C) and illuminated mode (10 to 50°C), requiring mode-dependent setpoint selection.
- Lighting Configuration Constraint: The chamber provides three-side lighting with six-step adjustable illumination from 0 to 20000 lx, and the lighting form is model-specific.
- Installation Space Constraint: Installation requires an external footprint of 830 x 850 x 1850 mm and accessible air inlets, test ports, shelving, drain areas, doors, and controller surfaces.
- Optional Accessory Integration Constraint: Optional RS232/485 communication, printer, USB storage, wireless alarm, CO2 inlet, infrared CO2 controller, and light-intensity detection systems require additional configuration and calibration.
Proper installation requires confirmed space and power, careful unpacking and positioning, and ensuring accessibility for maintenance. The chamber must be kept upright during transport and positioned with suitable lifting equipment.
Required Equipment: Suitable lifting equipment (e.g., forklift or pallet jack)
- Confirm Installation Space and Power
Confirm the installation space against the external dimensions of 830 x 850 x 1850 mm and prepare the specified AC 220 V, 50 Hz power supply. - Keep Chamber Upright During Transport
Keep the packed chamber upright during transport and unloading to prevent damage to the compressor and internal components. - Position Chamber with Lifting Equipment
Use suitable lifting equipment to position the chamber in the designated location, ensuring stable and level placement. - Ensure Accessibility for Maintenance
Ensure that air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance.
What is the temperature uniformity and fluctuation under illuminated conditions for the MGC-300B light incubator?
The temperature fluctuation and uniformity is ±1°C for both no-light and illuminated modes. The illuminated mode operates from 10 to 50°C, and the unit uses an imported compressor and circulation-fan assembly to maintain stability. No separate uniformity specification is provided for the illuminated state beyond the stated ±1°C.
Can the LCD Light Incubator MGC-300B be integrated with external data logging or CO2 control systems?
Yes, optional accessories include an RS232/485 communication interface and software, embedded printer, USB data storage, CO2 inlet, and infrared CO2 controller. These allow integration with external monitoring, data logging, and atmosphere control for specific applications such as plant growth or microbial culture requiring documented conditions.
What are the continuous operation recommendations and over-temperature protection features for the 300L incubator?
The unit is recommended for continuous operation schedules of not less than 180 hours under proper installation conditions. It features independent over-temperature alarm protection that stops the unit and alerts users when abnormal temperature conditions occur, reducing operational risk to samples and providing early notification of chamber anomalies.
The AF-MLB0300 (MGC-300B) 300 L LCD light incubator provides a 304 stainless-steel chamber with fluorine-free compressor cooling, six-step adjustable illumination up to 20000 lx, and a temperature range of 4–50 °C (no-light) or 10–50 °C (illuminated), suitable for microbial culture, plant growth, and seed testing. Its design includes imported compressor and fan components, rounded interior corners, and optional RS232/485 communication, CO2 inlet, and light-intensity detection, but lacks active humidity control and requires a minimum 180-hour continuous operation schedule for stable performance.
Positive
- Fluorine-free compressor cooling: The imported compressor and circulation-fan assembly provide efficient, low-temperature operation with reduced environmental impact, supporting stable chamber recovery and long service life during repeated use.
- 304 stainless-steel interior with rounded corners: The chamber interior is constructed from 304 stainless steel with rounded corners and removable shelving, improving cleaning efficiency, hygiene, and sample layout flexibility for long-duration laboratory workflows.
Trade-offs
- No active humidity control: The unit does not include active humidity regulation, limiting its use in applications requiring precise moisture control, such as certain plant tissue culture or microbial assays.
- Minimum 180-hour continuous operation recommended: For stable performance, the chamber is recommended for continuous operation schedules of not less than 180 hours under proper installation conditions, which may constrain intermittent use patterns.