LCD Light Incubator 300 L 0-15000 lx AF-MLA0300 ATOMFAIR®

$6,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

300 L LCD light incubator with 4-50 °C no-light and 10-50 °C illuminated control, 0-15000 lx six-step lighting, 304 stainless chamber and LCD control.

SKU: AF-LE-E-MGLI-0300-A300
Category:
Brands:

LCD Light Incubator, 300 L
Research-grade laboratory product
Product Overview

LCD Light Incubator, 300 L is a LCD light incubator built for microbial culture, plant cultivation, seed testing, insect rearing and other light-controlled incubation workflows. This configuration provides 300 l chamber volume, No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C, 0 to 15000 lx, six-step adjustable illumination, 304 stainless-steel chamber interior with removable shelving and lcd microcomputer controller with menu-based operation and large-screen data display for stable day-to-day laboratory operation.

This family uses fluorine-free design, imported compressor and fan components, stainless-steel interior construction, rounded internal corners, adjustable shelf spacing and a left-side test port for measurement access. The chamber combines imported compressor and circulation-fan assembly with microcomputer temperature-control system, 3 shelves and an interior size of 520 x 550 x 1140 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

These LCD models are positioned for laboratories that need stable illuminated incubation with selectable single-side, double-side, three-side or partition lighting, plus optional communication, alarm and atmosphere-related accessories. Installation planning can be based on the external size of 830 x 850 x 1850 mm and the stated power requirement of 1200 W. Optional functions such as rs232/485 communication interface and software; embedded printer; usb data storage; wireless alarm system; co2 inlet; infrared co2 controller; light-intensity detection and control system allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-MLA0300
Manufacturer Model MGC-300A
Capacity 300 L
Temperature Control Range No-light mode: 4 to 50 C; illuminated mode: 10 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity +/- 1 C
Humidity Function No active humidity control stated for this configuration
Lighting Configuration 0 to 15000 LX, six-step adjustable; double-side lighting; Lighting form varies by model and includes single-side, double-side, three-side or partition lighting
Controller LCD microcomputer controller with menu-based operation and large-screen data display
Chamber Material 304 stainless-steel chamber interior with removable shelving
Power / Input 1200 W
Power Supply AC 220 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration microcomputer temperature-control system
Cooling System imported compressor and circulation-fan assembly
Continuous Operation Guidance Recommended for continuous operation schedules of not less than 180 hours under proper installation conditions
Internal Dimensions 520 x 550 x 1140 mm
External Dimensions 830 x 850 x 1850 mm
Shelves / Light Decks 3 shelves
Program Function Standard LCD control for routine lighting and temperature operation
Optional Accessories and Functions RS232/485 communication interface and software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; infrared CO2 controller; light-intensity detection and control system
Performance Features
  • LCD menu control and large-screen display keep temperature and lighting values visible during routine laboratory operation. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Fluorine-free cooling design with imported compressor and fan components supports efficient chamber running and long service life. This helps maintain dependable low-temperature performance and stable chamber recovery during repeated use.
  • 304 stainless-steel interior construction with rounded corners and removable shelving helps improve cleaning efficiency and sample layout flexibility. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Model-specific lighting structures allow the user to match illumination intensity and distribution to cultivation depth and chamber size. This is valuable for plant-growth and photoperiod experiments that depend on repeatable lighting conditions.
  • Independent over-temperature alarm protection helps stop the unit and alert users when abnormal temperature conditions occur. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
  • Optional communication, printing, USB storage, CO2 and light-detection functions extend the chamber for documented and application-specific workflows. This is valuable for plant-growth and photoperiod experiments that depend on repeatable lighting conditions.
APPLICATION SCOPE: Suitable for microbial culture, plant cultivation, seed testing, insect rearing and other light-controlled incubation workflows in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 830 x 850 x 1850 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber must be installed in an environment with ambient temperature between 5 and 30 °C and powered by AC 220 V, 50 Hz. Continuous operation is recommended for at least 180 hours under proper installation, and the unit must be transported and positioned upright using suitable lifting equipment.

  • Ambient Temperature Constraint: Operate the chamber only in an ambient temperature range of 5 to 30 °C to ensure proper temperature control and compressor function.
  • Power Supply Requirement: Connect the chamber to a dedicated AC 220 V, 50 Hz power supply with the specified 1200 W capacity to avoid electrical overload.
  • Continuous Operation Guidance: Plan for continuous operation schedules of no less than 180 hours under proper installation conditions to stabilize the chamber environment.
  • Upright Transport Requirement: Keep the packed chamber upright at all times during transport and use suitable lifting equipment to prevent damage to the compressor and refrigeration system.
  • Over-Temperature Alarm Protection: The independent over-temperature alarm will stop the unit and alert users when abnormal temperature conditions occur, requiring immediate operator attention.

Confirm the installation space and power supply, then unpack the chamber upright and position it using lifting equipment. After setup, configure the temperature and lighting parameters on the LCD controller and begin continuous operation for at least 180 hours.

Required Equipment: Suitable lifting equipment

  1. Confirm Installation Space
    Confirm the installation space against the external dimensions of 830 x 850 x 1850 mm and ensure adequate clearance for ventilation and access.
  2. Prepare Power Supply
    Prepare the specified power supply of AC 220 V, 50 Hz with a capacity of 1200 W and verify that the outlet is grounded.
  3. Unpack Chamber
    Unpack the chamber carefully, keeping it upright at all times to avoid damaging the compressor and refrigeration system.
  4. Position Chamber
    Use suitable lifting equipment to position the chamber in the prepared installation space, ensuring all access points are clear.
  5. Ensure Accessibility
    Ensure that air inlets, test ports, shelving, drain areas, doors, and controller surfaces are accessible for cleaning and maintenance.
  6. Set Operating Parameters
    Set the desired temperature and lighting parameters using the LCD microcomputer controller with menu-based operation.
  7. Begin Continuous Operation
    Allow the chamber to operate continuously for at least 180 hours under proper installation conditions to stabilize the internal environment.

Why does the temperature range narrow from 4–50°C to 10–50°C when the light is on, and how should this affect experimental design?

The narrower range in illuminated mode occurs because the lighting system generates heat, preventing the chamber from reaching the same low temperatures as in no-light mode. For experiments requiring temperatures below 10°C, users should plan to operate without illumination or use supplementary external cooling.

Can this incubator be integrated with external monitoring or CO2 control for specialized applications like seed germination or cell culture?

Yes, optional accessories include an RS232/485 communication interface and software for data logging and remote monitoring, as well as a CO2 inlet and infrared CO2 controller for atmosphere supplementation. However, these functions are not standard and must be specified at ordering; the base configuration does not include active humidity control.

What are the continuous operation and installation requirements to maintain stable performance and avoid system overload?

The incubator is recommended for continuous operation of not less than 180 hours under proper installation conditions. It requires a 220 V, 50 Hz power supply rated at 1200 W, an ambient working environment of +5 to 30°C, and adequate space for the external dimensions of 830 x 850 x 1850 mm with accessible air inlets and ports for cleaning and maintenance.

The LCD Light Incubator 300 L (MGC-300A) provides 300 L capacity with 0–15000 lx six-step adjustable illumination, temperature range 4–50°C (no-light) / 10–50°C (illuminated), and 304 stainless steel interior. Its fluorine-free compressor-based cooling and optional communication, CO₂, and light-detection accessories support controlled incubation workflows in research and quality-control labs.

Positive

  • Fluorine-free compressor cooling: Imported compressor and circulation-fan assembly with fluorine-free design supports efficient low-temperature operation and long service life, maintaining stable chamber recovery during repeated use.
  • 304 stainless steel interior: Rounded corners and removable shelving improve cleaning efficiency and sample layout flexibility, supporting repeated hygiene and long-duration laboratory use.

Trade-offs

  • No active humidity control: The unit does not include active humidity regulation; applications requiring specific humidity levels must rely on optional accessories or external conditioning.
  • Requires 1200 W and dedicated space: The 1200 W power input and external dimensions of 830 x 850 x 1850 mm demand a prepared electrical supply and sufficient installation space, which may limit placement in crowded laboratories.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).