LCD Artificial Climate Chamber, 300 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This chamber requires a stable installation environment with adequate space and power supply. It must be kept upright during transport and positioned for routine maintenance access.
- Installation Space: The installation space must accommodate the external dimensions of 830 x 850 x 1850 mm and allow clear access to all vents, ports, and drains.
- Power Supply: The power supply must be AC 220 V, 50 Hz with a capacity of 1500 W and proper grounding.
- Operating Environment: The chamber must be operated in an ambient environment of +5 to 30°C.
- Continuous Operation: Continuous operation is recommended for schedules of not less than 180 hours under proper installation conditions.
- Transport and Positioning: The chamber must be kept upright during transport and unloaded using suitable lifting equipment.
Follow these steps to install and prepare the chamber for operation. Ensure all safety and handling precautions are observed.
Required Equipment: Suitable lifting equipment (e.g., forklift or pallet jack)
- Confirm Installation Space
Confirm that the installation space meets the required dimensions and provides clear access to all chamber vents, ports, and drains. - Prepare Power Supply
Prepare a dedicated AC 220 V, 50 Hz power outlet with sufficient capacity and grounding. - Position Chamber
Position the chamber upright using suitable lifting equipment and ensure it remains level and stable. - Verify Accessibility
Verify that all air inlets, test ports, shelving, drain areas, doors, and controller surfaces are unobstructed and accessible. - Configure and Start
Set the desired temperature, humidity, and light parameters via the LCD microcomputer controller and activate the over-temperature alarm protection.
Why is the temperature range narrower in illuminated mode (10–50 °C) compared to no-light mode (4–50 °C) for the MGC-300H climate chamber?
The illuminated mode requires the lighting system to be active, which generates additional heat inside the chamber. This heat load reduces the compressor's ability to pull the interior temperature as low as in no-light operation, so the lower limit rises from 4 °C to 10 °C. The specification explicitly states: no-light mode: 4 to 50 °C; illuminated mode: 10 to 50 °C.
What communication, data logging, and atmosphere control options can be integrated with the 300 L LCD artificial climate chamber?
The chamber supports optional RS232/485 communication interface and software, an embedded printer, USB data storage, a wireless alarm system, a CO2 inlet, and an infrared CO2 controller. Light-intensity detection and control is also optionally available. These accessories allow the unit to be adapted for alarm notification, data output, programmable operation, or CO2 enrichment for advanced climate-control tasks.
What are the critical installation specifications and safety features for the 300 L artificial climate chamber?
The chamber requires a 1500 W power supply at AC 220 V, 50 Hz, and a working environment of +5 to 30 °C. External dimensions are 830 x 850 x 1850 mm, and the unit is recommended for continuous operation schedules of not less than 180 hours. An independent over-temperature alarm helps safeguard samples during unattended running by notifying operators when abnormal conditions occur.
The LCD Artificial Climate Chamber, 300 L (AF-LE-E-MGAC-0300-H300) provides coordinated temperature, humidity, and light control with a 300 L capacity, 304 stainless-steel interior, and imported compressor/humidity sensor, but exhibits humidity deviation up to ±7% RH and requires a conditioned lab environment.
Positive
- Imported compressor and humidity sensor: The chamber uses imported compressor and humidity sensor components, supporting more reliable environmental tracking for humidity-sensitive incubation, cultivation, and stability studies.
- 304 stainless-steel interior with removable shelving: The 304 stainless-steel chamber interior with removable shelving improves hygiene, cleaning access, and sample-space adjustment for long-duration laboratory use.
Trade-offs
- Humidity tolerance up to ±7% RH: The humidity control deviation of ±5% to ±7% RH may be insufficient for applications requiring precise humidity stability, such as certain pharmaceutical or material conditioning studies.
- Requires conditioned lab environment: The chamber requires an ambient working environment of +5 to 30°C, meaning it must be installed in a temperature-controlled laboratory space to maintain specified performance.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).