190 L IR CO2 Incubator 90 °C Sterilization ATOMFAIR®

$6,900.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 190 L CO2 incubator with IR sensing, 0-20% CO2 control, ±0.1% accuracy, 90 °C sterilization, and 3 shelves for routine cell culture. Order now.

SKU: AF-LE-E-CHCW-0190-19HH
Category:
Brands:

190 L Gas-Jacket 90 °C Sterilization CO2 Incubator, IR Sensor Economy Series
Research-grade laboratory product
Product Overview

190 L Gas-Jacket 90 °C Sterilization CO2 Incubator, IR Sensor Economy Series is designed for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows. Infrared CO2 control with gas-jacket or water-jacket chamber options and sterilization variants for different culture workflows. The configuration provides RT + 5 to 55 °C, 750 W rated power, a working chamber of 520 × 530 × 690 mm (W × D × H), and external dimensions of 708 × 710 × 1030 mm (W × D × H).

The control and chamber design support practical laboratory operation: laboratory controller. laboratory chamber construction The model includes 3 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Humidity display; printer; communication interface; gas regulator; optional HEPA filtration.

This equipment is suited to laboratories that need cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2E-190H
Product Family CO2 Incubator, IR Sensor Economy Series
Configuration 190 L Gas-Jacket 90 °C Sterilization
Rated Operating Power 750 W
Working Chamber Size 520 × 530 × 690 mm (W × D × H)
Overall Dimensions 708 × 710 × 1030 mm (W × D × H)
Shelf Configuration 3 shelves
Power Supply AC 220 V, 50 Hz
Temperature Control Range RT + 5 to 55 °C
Working Ambient Temperature +5 to +30 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
Temperature Recovery Time No more than 8 minutes to recover to 37 °C after a 30-second door opening
Relative Humidity Natural evaporation, 90% or higher
Optional Accessories and Functions Humidity display; printer; communication interface; gas regulator; optional HEPA filtration
Performance Features
  • Infrared CO2 sensing supports stable CO2 control in routine culture workflows. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Gas-jacket, water-jacket, UV sterilization, and 90 °C sterilization variants are available within this product family. This supports chamber hygiene and contamination-control routines for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Microbial filtration at the gas inlet helps reduce contamination risk in the chamber atmosphere. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Door heating, circulation control, and optional HEPA filtration support cleaner culture operation. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Optional humidity display, printer, communication interface, and gas regulator accessories are listed. This allows the configuration to match documentation, communication and monitoring needs in cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • The family is described as a value-focused upgrade line for routine non-medical laboratory use. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
APPLICATION SCOPE: Suitable for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 708 × 710 × 1030 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Humidity display; printer; communication interface; gas regulator; optional HEPA filtration. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This incubator requires specific environmental and safety conditions for reliable operation. Adhere to the listed constraints to prevent equipment damage or user injury.

  • Power Supply Requirement: The unit must be connected to an AC 220 V, 50 Hz power supply with the rated operating power of 750 W.
  • Ambient Temperature Range: Operate the incubator only within an ambient temperature range of +5 to +30 °C.
  • Transport Orientation: Keep the packed unit upright during transport and use suitable lifting equipment to avoid impact damage.
  • Accessibility for Maintenance: Position the incubator so that the chamber, sensors, shelves, filters, doors, test ports, and control interfaces remain accessible for cleaning, inspection, and operation.
  • Optional Accessory Selection: Select optional accessories (humidity display, printer, communication interface, gas regulator, HEPA filtration) according to the required workflow before installation.

This procedure guides the installation and initial setup of the CO2 incubator. Follow these steps to ensure safe operation and proper configuration for cell culture workflows.

Required Equipment: Suitable lifting equipment

  1. Confirm Installation Space
    Confirm that the installation space accommodates the 708 × 710 × 1030 mm external dimensions and verify the availability of an AC 220 V, 50 Hz power supply.
  2. Unpack the Incubator
    Unpack the incubator while keeping it upright and using suitable lifting equipment to prevent damage.
  3. Position the Incubator
    Position the incubator in the prepared location, ensuring access to the chamber, sensors, shelves, filters, doors, test ports, and control interfaces.
  4. Install Optional Accessories
    Select and install any required optional accessories such as the humidity display, printer, communication interface, gas regulator, or HEPA filtration according to the workflow.
  5. Connect Power and Gas Supplies
    Connect the unit to the specified power supply and, if applicable, to the CO2 gas source using the appropriate regulator.
  6. Configure Setpoints
    Configure the temperature and CO2 setpoints as required for the specific culture protocol, ensuring the temperature control range is RT +5 to 55 °C and CO2 range 0 to 20%.
  7. Perform Sterilization Cycle
    Perform a 90 °C sterilization cycle before loading cultures if the workflow requires a sterile chamber environment.

How quickly does the Atomfair AF-CO2E-190H CO2 incubator recover CO2 concentration and temperature after a typical 30-second door opening?

After a 30-second door opening, the CO2 concentration recovers to 5% within no more than 3 minutes, and the temperature recovers to 37°C within no more than 8 minutes, as specified in the technical specifications. These recovery times support repeatable incubation conditions during routine cell culture workflows in the 190 L gas-jacket model with infrared CO2 sensor.

What are the limitations of the Economy Series CO2 incubator for regulated research or clinical applications?

The Atomfair AF-CO2E-190H is part of the IR Sensor Economy Series, described as a value-focused upgrade line for routine non-medical laboratory use. While suitable for cell culture and CO2-controlled incubation in universities and quality-control labs, it may not meet GMP or clinical-grade requirements. Optional accessories such as HEPA filtration and communication interfaces can extend functionality but are not standard.

What are the installation space and power supply requirements for the Atomfair AF-CO2E-190H 190 L CO2 incubator?

The incubator has external dimensions of 708 × 710 × 1030 mm (W × D × H) and requires an AC 220 V, 50 Hz power supply with a rated power of 750 W. The installation space must accommodate these dimensions and allow access to the chamber, sensors, shelves, filters, and control interfaces for cleaning and operation. A working ambient temperature of +5 to +30 °C is also required.

The 190 L Gas-Jacket CO2 Incubator with IR sensor provides rapid CO2 and temperature recovery and 90°C sterilization, but its ambient temperature range and optional accessory dependency require careful lab infrastructure planning.

Positive

  • Infrared CO2 sensor with fast recovery: Infrared CO2 control with ±0.1% accuracy and CO2 recovery time ≤3 minutes to 5% after a 30-second door opening, enabling stable culture conditions.
  • 90°C sterilization and gas-jacket design: Gas-jacket heating and 90°C sterilization cycle support routine decontamination and reduce contamination risk, suitable for sensitive cell culture.

Trade-offs

  • Ambient temperature dependency: Requires working ambient temperature +5 to +30°C, limiting placement in unconditioned laboratories or warm environments.
  • Optional accessories not included: Humidity display, printer, communication interface, gas regulator, and HEPA filtration are optional; base unit lacks these features, requiring additional procurement and integration.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).