High Precision Electronic Balance 0.1mg OIML R76 ATOMFAIR®

$495.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

OIML R76 compliant analytical balance with 0.1mg readability and 100g capacity. Features RS232 output, ≤3s stabilization, anti-static design. In stock.

Brands:

Description

ATOMFAIR® HIGH PRECISION ELECTRONIC ANALYTICAL BALANCE SERIES / FA-MULTIMODEL

RESEARCH GRADE MATERIAL

Product Overview

The ATOMFAIR® premium **electronic analytical balance** matrix comprises 6 advanced high-precision models (FA1004E, FA1104E, FA1204E, FA2004, FA2104, and FA2204E) tailored to meet strict diagnostic demands across industrial cleanrooms, third-party screening nodes, and university laboratories. Delivering a refined **readability 0.0001g** with an ultra-short stabilization response window, these instruments merge advanced electromagnetic sensor architectures with specialized anti-vibration layouts. This comprehensive matrix guarantees exceptional data repeatability for micro-powder metrics and sensitive compound scaling, eliminating ambient noise anomalies to capture true sample mass values during micro-chemical synthesis and quality control routines.

Technical Comparison: Models FA1004E, FA1104E & FA1204E

SPECIFICATION ITEM FA1004E (N) FA1104E (N) FA1204E (N)
Maximum Capacity 100 g 100 g 100 g
Accuracy (Readability) 0.0001 g 0.0001 g 0.0001 g
Minimum Weight Window 0.0004 g 0.0004 g 0.0004 g
Stabilization Time ≤ 3 seconds ≤ 3 seconds ≤ 3 seconds
Display Configuration High-Contrast LCD featuring crisp white backlight and clear black font geometries
Weighing Pan Size Φ80 mm (Standard Baseline Configuration) | Φ90 mm (Optional Architecture)
Operating Temperature 5 °C – 35 °C ambient cell climate boundaries
Repeatability Deviation ±0.0002 g ±0.0002 g ±0.0002 g
Linearity Error Limit ±0.0003 g ±0.0003 g ±0.0003 g
Data Output Ports RS232C (Standard Integrated Bus) | RS485 / USB / Direct Printer Connection (Optional)
Packing Frame Sizes 425 mm × 320 mm × 415 mm dimensional transit box layout
Gross Structural Weight 6.0 kg 6.0 kg 6.0 kg
Core Model Focus & Built-In Feature Advantages • Advanced electromagnetic sensor arrays secure stable results.
• Windproof, anti-static cage configuration optimal for micro-powders.
• Simplified button layout maximizes routine industrial lab workflows.
• Ultra-rapid internal data processing curtails structural stabilization wait times.
• One-key interface toggle across multi-units (g, mg, kg metrics).
• Anti-vibration logic limits surrounding draft or mechanical line jitter errors.
• High-definition backlight preserves character readability in dark gloveboxes.
• Ergonomic pressure key engineering shields against technician processing strain.
• Built to manage intensive multi-batch analytics for quality validation loops.


Technical Comparison: Models FA2004, FA2104 & FA2204E

SPECIFICATION ITEM FA2004 (N) FA2104 (N) FA2204E (N)
Maximum Capacity 100 g 100 g 100 g
Accuracy (Readability) 0.0001 g 0.0001 g 0.0001 g
Minimum Weight Window 0.0004 g 0.0004 g 0.0004 g
Stabilization Time ≤ 3 seconds ≤ 3 seconds ≤ 3 seconds
Display Configuration High-Contrast LCD featuring crisp white backlight and clear black font geometries
Weighing Pan Size Φ80 mm (Standard Baseline Configuration) | Φ90 mm (Optional Architecture)
Operating Temperature 5 °C – 35 °C ambient cell climate boundaries
Repeatability Deviation ±0.0002 g ±0.0002 g ±0.0002 g
Linearity Error Limit ±0.0003 g ±0.0003 g ±0.0003 g
Data Output Ports RS232C (Standard Integrated Bus) | RS485 / USB / Direct Printer Connection (Optional)
Packing Frame Sizes 425 mm × 320 mm × 415 mm dimensional transit box layout
Gross Structural Weight 6.0 kg 6.0 kg 6.0 kg
Core Model Focus & Built-In Feature Advantages • Onboard hardware memory cache streamlines digital lab documentation logs.
• All-metal rigid monocoque outer shell delivers extended wear resistance.
• Highly tailored for third-party auditing lines and elite university labs.
• Specialized alloy pan surface resists aggressive cross-contamination arrays.
• Unbiased reading stability during trace analytical chemistry screening steps.
• Silent structural actuation maintains a quiet, zero-distraction laboratory.
• Intelligent internal auto-calibration logic tracking prevents shifting errors.
• Eco-conscious low power requirement curves minimize electricity waste loops.
• Perfect fit for everyday analytical workflows inside quality test sites.

APPLICATION SCOPE: Optimized across research setups conducting high-accuracy micro-powder evaluations, trace chemical parsing, battery electrolyte mass indexing, legal third-party certification workflows, and industrial production quality monitoring cycles.
PACKAGING & LOGISTICS: Shipped as individual high-mass validation kits inside drop-tested protective boxes measuring 425 × 320 × 415 mm. For customized platform sizing data or official commercial pricing estimates, communicate directly via inquiry@atomfair.com.
IMPORTANT NOTICE / DISCLAIMER: Always position the balance framework upon an isolated anti-vibration stone slab benchtop within a controlled ambient profile between 5 and 35 °C. Calibrate the underlying internal transducer matrix periodically prior to capturing critical data series. Do not overload the structural weighing pan beyond the 100g max ceiling capacity limit to protect sensitive electrical components.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This analytical balance requires an ambient temperature range of 5°C to 35°C and a stable, vibration-free environment to maintain specified accuracy. The instrument is sensitive to airflow and static electricity, necessitating use of the integrated windproof and anti-static design features.

  • Temperature Constraint: Operating temperature must be maintained between 5°C and 35°C to ensure consistent weighing performance.
  • Vibration and Airflow Sensitivity: Place the balance on a stable, level surface away from drafts, vibrations, and direct airflow to prevent measurement errors.
  • Anti-static Measures: Use the built-in anti-static design features when weighing micro-powders or hygroscopic samples to avoid electrostatic interference.
  • Calibration Requirement: Regular calibration is required to maintain metrological compliance with OIML R76 standards.
  • Leveling Requirement: Level the balance using the adjustable feet and built-in level indicator before each use to ensure accurate readings.

What is the minimum sample weight for reliable weighing on the Atmofair 0.1mg analytical balance and how does repeatability affect low-mass measurements?

The minimum weight for reliable weighing is 0.0004g (400µg), ensuring accuracy above the repeatability threshold of ±0.0002g. For samples below 0.0004g, the repeatability error becomes significant relative to the reading, compromising measurement confidence.

Can the Atmofair 0.1mg analytical balance be integrated with laboratory data systems via RS232C or USB?

Yes, the balance includes an RS232C output port as standard and offers optional RS485, USB, or printer interfaces for seamless integration with LIMS or data acquisition systems. This allows direct data transmission and storage, as highlighted in the FA2004 model's advantages.

What environmental conditions and sample handling precautions are required for accurate operation of the Atmofair 0.1mg analytical balance?

The balance is designed for operating temperatures between 5°C and 35°C and features a windproof and anti-static design to mitigate airflow and electrostatic interference. It also incorporates anti-vibration and anti-airflow shielding, making it suitable for micro-powder and high-value sample weighing in complex lab environments.

This series of high-precision analytical balances (0.1 mg readability) employs advanced sensor technology with windproof and anti-static enclosure, delivering ≤3 s stabilization and ±0.0002 g repeatability. The narrow 5–35°C operating range and reliance on optional USB/RS485 interfaces necessitate careful environmental control and connectivity planning for laboratory integration.

Positive

  • Advanced sensor with fast stabilization: The balance adopts advanced sensor technology and achieves stabilization in ≤3 seconds, reducing waiting time and improving weighing throughput for routine lab work.
  • Windproof and anti-static design: Integrated windproof and anti-static construction, combined with anti-vibration and anti-airflow interference, enables reliable weighing of micro-powders and high-value samples in complex laboratory environments.

Trade-offs

  • Narrow operating temperature range: The specified operating range of 5°C to 35°C requires a climate-controlled laboratory environment; deviations outside this window may degrade measurement stability and accuracy.
  • Limited standard data interface: The balance ships with only an RS232C port; modern USB or RS485 connectivity is optional, potentially requiring additional adapters or cabling for direct integration with contemporary data acquisition systems.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).