Gas-Jacket CO2 Incubator 50 L IR Sensor 450 W ATOMFAIR®

$3,300.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

50 L gas-jacket CO2 incubator with IR sensing, UV sterilization, 0 to 20% CO2 control, ±0.1% accuracy, 450 W power, and 2 shelves. Order now.

SKU: AF-LE-E-CHCW-0050-50CH
Category:
Brands:

50 L Gas-Jacket UV Sterilization CO2 Incubator, IR Sensor Economy Series
Research-grade laboratory product
Product Overview

50 L Gas-Jacket UV Sterilization CO2 Incubator, IR Sensor Economy Series is designed for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows. Infrared CO2 control with gas-jacket or water-jacket chamber options and sterilization variants for different culture workflows. The configuration provides RT + 5 to 55 °C, 450 W rated power, a working chamber of 400 × 350 × 350 mm (W × D × H), and external dimensions of 580 × 450 × 730 mm (W × D × H).

The control and chamber design support practical laboratory operation: laboratory controller. laboratory chamber construction The model includes 2 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Humidity display; printer; communication interface; gas regulator; optional HEPA filtration.

This equipment is suited to laboratories that need cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2E-050G
Product Family CO2 Incubator, IR Sensor Economy Series
Configuration 50 L Gas-Jacket UV Sterilization
Rated Operating Power 450 W
Working Chamber Size 400 × 350 × 350 mm (W × D × H)
Overall Dimensions 580 × 450 × 730 mm (W × D × H)
Shelf Configuration 2 shelves
Power Supply AC 220 V, 50 Hz
Temperature Control Range RT + 5 to 55 °C
Working Ambient Temperature +5 to +30 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
Temperature Recovery Time No more than 8 minutes to recover to 37 °C after a 30-second door opening
Relative Humidity Natural evaporation, 90% or higher
Optional Accessories and Functions Humidity display; printer; communication interface; gas regulator; optional HEPA filtration
Performance Features
  • Infrared CO2 sensing supports stable CO2 control in routine culture workflows. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Gas-jacket, water-jacket, UV sterilization, and 90 °C sterilization variants are available within this product family. This supports chamber hygiene and contamination-control routines for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Microbial filtration at the gas inlet helps reduce contamination risk in the chamber atmosphere. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Door heating, circulation control, and optional HEPA filtration support cleaner culture operation. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Optional humidity display, printer, communication interface, and gas regulator accessories are listed. This allows the configuration to match documentation, communication and monitoring needs in cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • The family is described as a value-focused upgrade line for routine non-medical laboratory use. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
APPLICATION SCOPE: Suitable for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 580 × 450 × 730 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Humidity display; printer; communication interface; gas regulator; optional HEPA filtration. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Operate within the specified ambient temperature range of +5 to +30°C and power supply of AC 220V, 50Hz. Ensure the unit is installed with adequate clearance for airflow and access to chamber, sensors, and control interfaces.

  • Transport and Handling: Transport the incubator upright and use suitable lifting equipment to prevent damage during movement.
  • Installation Space Verification: Confirm the available space meets the external dimensions of 580×450×730 mm before installation.
  • Accessibility Requirements: Keep the chamber, sensors, shelves, filters, doors, test ports, and control interfaces accessible for cleaning, inspection, and operation.
  • Optional Accessory Selection: Select optional accessories (humidity display, printer, communication interface, gas regulator, HEPA filtration) according to the required workflow.
  • Gas Inlet Filter Maintenance: Maintain the microbial filter at the gas inlet to reduce contamination risk in the chamber atmosphere.

This procedure describes the initial setup and safe operation of the 50L gas-jacket CO2 incubator. Follow these steps to install, configure, and begin incubation while maintaining chamber hygiene and accessibility.

Required Equipment: Suitable lifting equipment, Power supply (AC 220V, 50Hz), Gas regulator (optional), HEPA filter (optional)

  1. Transport to Installation Site
    Transport the packed incubator upright using suitable lifting equipment to the installation area.
  2. Verify Installation Space and Power
    Confirm that the installation space accommodates the external dimensions (580×450×730 mm) and provides the required AC 220V, 50Hz power supply.
  3. Position and Access
    Position the incubator and ensure the chamber, sensors, shelves, filters, doors, test ports, and control interfaces remain accessible.
  4. Connect Power and Accessories
    Connect the power supply and install any selected optional accessories (e.g., gas regulator, HEPA filter, communication interface).
  5. Set Temperature and CO2 Parameters
    Set the temperature control to the desired setpoint within the range RT+5 to 55°C and CO2 concentration within 0 to 20%.
  6. Stabilize Chamber Conditions
    Allow the chamber to stabilize to the set temperature and CO2 concentration before loading samples.
  7. Load Samples and Begin Incubation
    Load culture samples onto the shelves and initiate the incubation workflow.

What is the CO2 recovery time after a 30-second door opening, and how does the infrared sensor maintain ±0.1% accuracy?

The CO2 recovery time is no more than 3 minutes to return to 5% concentration after a 30-second door opening. The infrared CO2 sensor provides ±0.1% control accuracy, enabling stable CO2 conditions for routine culture workflows as specified in the technical specifications.

Which optional accessories are required to enable data logging and remote monitoring of incubation conditions in this 50L gas-jacket CO2 incubator?

Optional communication interface and printer accessories are available for data logging and remote monitoring. The communication interface allows external data recording, while the printer provides hard-copy records of temperature, CO2, and humidity parameters. These are listed as optional functions in the product description.

How is humidity maintained above 90% without active humidification in this gas-jacket CO2 incubator?

Humidity is achieved through natural evaporation from a water pan, reaching 90% or higher as stated in the technical specifications. The gas-jacket heating system provides uniform temperature distribution, which supports stable evaporation and minimizes condensation, maintaining high humidity for sensitive cell culture workflows.

The 50 L Gas-Jacket UV Sterilization CO2 Incubator with IR sensor provides ±0.1% CO2 accuracy and ≤3-minute CO2 recovery after door opening, but requires a strictly controlled ambient temperature range of +5 to +30 °C and relies on natural evaporation for humidity, which limits precision in moisture-sensitive applications.

Positive

  • Infrared CO2 sensing with fast recovery: Infrared sensor achieves ±0.1% CO2 control accuracy and recovers to 5% CO2 within 3 minutes after a 30-second door open, maintaining stable culture conditions.
  • Gas-jacket design with UV sterilization: Gas-jacket heating combined with UV sterilization and microbial gas inlet filtration reduces contamination risk in routine cell culture workflows.

Trade-offs

  • Narrow ambient temperature tolerance: The incubator requires a working ambient temperature of +5 to +30 °C; operation outside this range may compromise temperature control stability and recovery performance.
  • Passive humidity control via natural evaporation: Relative humidity is achieved only through natural evaporation (≥90% RH) without active humidification or feedback control, limiting reproducibility in humidity-sensitive applications.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).