Four-Sided Strong-Light Incubator, 460 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a level position with adequate ventilation and a stable ambient temperature. When set temperature is 10°C or below, ambient temperature must not exceed 26°C, and the chamber has no humidity control.
- Ambient Temperature Constraint: When set temperature is 10°C or below, ambient temperature should not exceed 26°C to maintain performance.
- Placement and Ventilation: Keep the chamber level and leave enough room for ventilation to ensure proper operation.
- Configuration Verification: Confirm the selected shelf and lighting configuration before operation as per the experiment requirements.
- No Humidity Control: The chamber does not provide humidity control, so environmental humidity must be managed externally if needed.
- Performance Data Reference: Performance data are measured at standard no-load test conditions and may differ under loaded conditions.
This procedure outlines the initial setup and configuration steps for the Four-Sided Strong-Light Incubator. Following these steps ensures safe and reliable operation for plant growth and incubation experiments.
- Position the Chamber
Position the chamber on a level surface with adequate ventilation, keeping it upright during unloading. - Confirm Configuration
Confirm the selected shelf and lighting configuration are appropriate for the intended experiment. - Verify Ambient Temperature Constraint
Verify that ambient temperature does not exceed 26°C when operating at a set temperature of 10°C or below.
What temperature uniformity can I expect from the Atomfair AF-GZX460F four-sided strong-light incubator, and how does that affect reproducibility in plant growth experiments?
The 460 L incubator maintains a temperature uniformity of ±1°C across the 5 to 60°C control range, with a resolution of 0.1°C. This level of uniformity, combined with the programmable LCD microcomputer controller, supports repeatable plant-growth and photoperiod experiments by keeping samples in a steady, repeatable working condition.
Can the four-sided strong-light incubator support high-light-demanding species with its 0 to 18000 lux illumination system?
Yes, the chamber provides 0 to 18000 lux across six adjustable levels from four sides (four-sided strong lighting), making it suitable for experiments requiring higher illumination intensity within a standard programmable incubation framework. The mirror-finish stainless-steel inner chamber and tempered-glass inner door further support observation of high-light-demanding samples.
What are the power and ambient temperature constraints for operating the 460 L four-sided incubator, especially at low set temperatures?
The incubator requires a 1200 W, AC220V 50Hz power supply. When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C. The unit has no humidity control, and performance data are measured under standard no-load test conditions. These factors should be considered when planning installation and experiment protocols.
The Four-Sided Strong-Light Incubator (460 L) provides high-intensity illumination up to 18000 lux from four sides with programmable temperature and light control, suitable for plant growth and microbial culture. However, operation below 10°C requires ambient temperature ≤26°C and the unit lacks humidity control.
Positive
- Four-sided strong lighting up to 18000 lux: Four-sided illumination at 18000 lux (6 levels) supports high-light-demanding plant growth and comparison experiments, enabling repeatable photoperiod studies.
- Programmable temperature and light control: LCD microcomputer controller with 0.1°C resolution and ±1°C uniformity maintains repeatable conditions across 5–60°C, supporting reproducible incubation and growth protocols.
Trade-offs
- Ambient temperature constraint at low setpoints: When set temperature is ≤10°C, ambient temperature must not exceed 26°C, limiting placement in warm labs or during summer operation without additional cooling.
- No humidity control: The chamber lacks built-in humidity regulation, restricting its use for experiments requiring precise or stable relative humidity levels.