Four-Sided Strong-Light Incubator, 280 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This incubator requires a level placement with adequate ventilation and an ambient temperature not exceeding 26°C when the set temperature is 10°C or below. It does not include humidity control, and performance data are measured under standard no-load test conditions.
- Ambient Temperature Limit: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C.
- Ventilation Requirement: The unit must be placed with sufficient clearance around it for proper ventilation.
- Level Placement: The incubator must be positioned on a level surface to ensure proper operation.
- No Humidity Control: This incubator does not provide humidity control; for applications requiring humidity, an external system is needed.
- Transport and Positioning: The unit must be kept upright during unloading and positioning to prevent damage.
Follow these steps to safely position, configure, and begin operation of the incubator. Ensure all constraints are met before use.
- Unload and Position
Keep the incubator upright during unloading and positioning to avoid damage. - Place on Level Surface
Place the chamber on a level surface and leave enough room for ventilation. - Configure Shelves and Lighting
Confirm the selected shelf and lighting configuration before operation. - Check Ambient Temperature
Verify that when set temperature is 10°C or below, ambient temperature does not exceed 26°C.
How does the four-sided illumination affect the temperature uniformity and stability of the incubator, especially at high light intensities?
The incubator maintains a temperature uniformity of ±1°C across the 280L chamber even with four-sided strong lighting up to 18000 lux. The LCD microcomputer programmable controller manages both temperature and light cycles to ensure repeatable conditions. The mirror-finish stainless-steel inner chamber and glass inner door aid in even light distribution.
What power supply specifications are required for the four-sided strong-light incubator, and can it be adapted for 110V grids?
The incubator requires a AC220V 50Hz power supply with a 1000W input. It is not designed for 110V or 60Hz operation without an external voltage converter or frequency adapter. Verify laboratory power infrastructure before installation.
What are the key ambient temperature and positioning requirements for reliable low-temperature operation?
When set temperature is 10°C or below, the ambient temperature must not exceed 26°C to maintain setpoint accuracy. The unit weighs 185 kg and must be placed on a level surface with adequate ventilation. No humidity control is provided, so external humidity management may be needed for sensitive applications.
The Atomfair AF-GZX280F four-sided strong-light incubator provides 280 L of usable space with programmable temperature and illumination control, making it suitable for plant growth and microbial culture, though its ±1°C uniformity and lack of humidity control impose operational constraints.
Positive
- Four-sided strong-light illumination: Provides up to 18,000 lux (6 levels) from four faces, enabling high-intensity, uniform light exposure for demanding plant-growth and photoperiod experiments.
- Programmable controller with safety features: The LCD microcomputer programmable controller includes self-diagnosis, over-temperature self-limiting, and power-off memory, ensuring repeatable conditions and protecting samples during routine use.
Trade-offs
- Moderate temperature uniformity and no humidity control: Temperature uniformity is ±1°C and the chamber lacks humidity control, limiting precision for applications requiring tighter thermal gradients or specific humidity regimes.
- Specific ambient and power requirements: When set temperature is ≤10°C, ambient must not exceed 26°C; the unit requires AC220V 50Hz and 1000W input power, demanding confirmed infrastructure before deployment.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).