Four-Chamber 400 L Incubator 65°C AF-MHIN-1004 ATOMFAIR®

$3,400.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade four-chamber incubator provides 400 L total capacity, 65 °C maximum temperature, 0.1 °C resolution, 1500 W power, and independent chamber control.

SKU: AF-LE-E-MHIN-1004-4B10
Category:
Brands:

Four-Chamber Electric Heated Constant Temperature Incubator, 100 L per Chamber
Research-grade laboratory product
Product Overview

Four-Chamber Electric Heated Constant Temperature Incubator, 100 L per Chamber is designed for parallel incubation, separated sample management, and laboratory workflows that require multiple independently controlled chambers. Two-chamber and four-chamber cabinet layouts for space-saving independent incubation control. The configuration provides RT + 5 to 65 °C, 1500 W rated power, a working chamber of 455 × 430 × 510 mm per chamber (W × D × H), and external dimensions of 1220 × 616 × 1620 mm (W × D × H).

The control and chamber design support practical laboratory operation: laboratory controller. Mirror-finish stainless-steel inner chamber The model includes 2 shelves per chamber.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Independent over-temperature controller and alarm configuration.

This equipment is suited to laboratories that need parallel incubation, separated sample management, and laboratory workflows that require multiple independently controlled chambers, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-MHIN-1004
Product Family Multi-Chamber Electric Heated Constant Temperature Incubator
Configuration 100 L × 4 chambers
Rated Operating Power 1500 W
Working Chamber Size 455 × 430 × 510 mm per chamber (W × D × H)
Overall Dimensions 1220 × 616 × 1620 mm (W × D × H)
Shelf Configuration 2 shelves per chamber
Temperature Control Range RT + 5 to 65 °C
Temperature Resolution / Fluctuation 0.1 °C / ±0.5 °C
Working Ambient Temperature +5 to +35 °C
Power Supply AC 220 V, 50 Hz
Chamber Control Each chamber is independently controlled
Chamber Material Mirror-finish stainless-steel inner chamber
Optional Accessories and Functions Independent over-temperature controller and alarm configuration
Performance Features
  • This product family offers dual-chamber and four-chamber cabinet layouts for space saving in the laboratory. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Each chamber is independently controlled for parallel work without mutual interference. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A stainless-steel inner chamber supports cleaning and maintenance. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • The product design lists independent over-temperature alarm support as an option. This helps operators identify abnormal conditions during unattended or extended parallel incubation, separated sample management, and laboratory workflows that require multiple independently controlled chambers.
  • High-temperature and over-temperature alarms are listed for this family. This helps operators identify abnormal conditions during unattended or extended parallel incubation, separated sample management, and laboratory workflows that require multiple independently controlled chambers.
  • The cabinet layout supports separated workflows and comparative incubation programs. This supports controlled, repeatable operation for parallel incubation, separated sample management, and laboratory workflows that require multiple independently controlled chambers.
APPLICATION SCOPE: Suitable for parallel incubation, separated sample management, and laboratory workflows that require multiple independently controlled chambers in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 1220 × 616 × 1620 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Independent over-temperature controller and alarm configuration. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator must be installed in a location with sufficient space for the 1220 × 616 × 1620 mm dimensions and access to an AC 220 V, 50 Hz power supply. An independent over-temperature controller is recommended to prevent thermal runaway during unattended operation.

  • Power Supply Constraint: The unit requires a dedicated AC 220 V, 50 Hz power supply with a rated power of 1500 W.
  • Ambient Temperature Constraint: The working ambient temperature must be between +5 and +35 °C to maintain proper operation.
  • Over-temperature Protection: An independent over-temperature controller and alarm configuration is available as an optional safety accessory.
  • Transport Constraint: During transport, the unit must be kept upright and handled with suitable lifting equipment to avoid damage.
  • Accessibility Constraint: Chamber, sensors, shelves, filters, doors, and control interfaces must remain accessible for cleaning, inspection, and operation.

Follow these steps to safely install and operate the incubator. Ensure all power and space requirements are met before starting.

Required Equipment: Suitable lifting equipment, Shelves, Optional independent over-temperature controller

  1. Inspect the installation site
    Confirm the available space meets the external dimensions of 1220 × 616 × 1620 mm and the power supply is AC 220 V, 50 Hz with 1500 W capacity.
  2. Install the incubator
    Use suitable lifting equipment to position the unit upright in the designated location, ensuring chamber access is unobstructed.
  3. Install shelves and optional accessories
    Insert the two shelves per chamber and install any optional independent over-temperature controller if required.
  4. Power on the system
    Connect the power cable and switch on the unit, allowing each chamber to stabilize at the ambient temperature.
  5. Set temperature parameters
    Adjust each chamber's independent controller to the desired incubation temperature within the range of RT+5 to 65 °C.

How does the ±0.5°C temperature fluctuation across four independently controlled chambers affect reproducibility in parallel incubation experiments?

The ±0.5°C fluctuation per chamber is typical for forced-air incubators and supports reproducible parallel incubation when chambers are not opened frequently. The independent control prevents cross-contamination of temperature profiles, but users should validate uniformity within each chamber before critical assays, as the source specifies a temperature fluctuation of ±0.5°C and a resolution of 0.1°C across the range of RT+5 to 65°C.

Can the Four-Chamber Incubator accommodate 100 L samples per chamber while maintaining setpoint stability under variable ambient conditions?

Yes, each 100 L chamber is independently controlled and maintains stability within ±0.5°C fluctuation at ambient temperatures from +5 to +35°C. The 1500 W total power is distributed across chambers, so simultaneous operation of all four chambers at 65°C is supported, though rapid ambient temperature changes may affect recovery time. The working chamber dimensions are 455×430×510 mm per chamber.

What installation requirements should be considered for the 1220×616×1620 mm Four-Chamber Incubator?

The unit requires AC 220 V, 50 Hz power supply with 1500 W rated power and adequate clearance for door opening and ventilation. The external dimensions are 1220×616×1620 mm (W×D×H); ensure the floor can support the weight. The optional independent over-temperature controller should be specified at order if needed for unattended operation, as it is listed as an optional accessory.

The Four-Chamber Electric Heated Constant Temperature Incubator (100 L per chamber) provides four independently controlled stainless-steel chambers with temperature control from RT+5 to 65°C (fluctuation ±0.5°C), mirror-finish interiors, and optional over-temperature alarm, enabling parallel incubation workflows with sample separation.

Positive

  • Independent chamber control: Each of the four chambers is independently controlled, allowing simultaneous incubation of different samples without cross-temperature interference, supporting separated sample management.
  • Mirror-finish stainless steel interior: The inner chamber is constructed from mirror-finish stainless steel, which facilitates thorough cleaning and reduces the risk of contamination between runs.

Trade-offs

  • Fixed AC 220V 50Hz power supply: The incubator requires AC 220 V, 50 Hz mains power; facilities with different voltage or frequency standards will need a step-down transformer or frequency converter, adding infrastructure cost.
  • Limited ambient temperature range: The specified working ambient temperature range of +5 to +35°C restricts placement to climate-controlled laboratories; operation outside this range may impair temperature stability or trigger alarms.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).