Four-Chamber Electric Heated Constant Temperature Incubator, 100 L per Chamber
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator must be installed in a location with sufficient space for the 1220 × 616 × 1620 mm dimensions and access to an AC 220 V, 50 Hz power supply. An independent over-temperature controller is recommended to prevent thermal runaway during unattended operation.
- Power Supply Constraint: The unit requires a dedicated AC 220 V, 50 Hz power supply with a rated power of 1500 W.
- Ambient Temperature Constraint: The working ambient temperature must be between +5 and +35 °C to maintain proper operation.
- Over-temperature Protection: An independent over-temperature controller and alarm configuration is available as an optional safety accessory.
- Transport Constraint: During transport, the unit must be kept upright and handled with suitable lifting equipment to avoid damage.
- Accessibility Constraint: Chamber, sensors, shelves, filters, doors, and control interfaces must remain accessible for cleaning, inspection, and operation.
Follow these steps to safely install and operate the incubator. Ensure all power and space requirements are met before starting.
Required Equipment: Suitable lifting equipment, Shelves, Optional independent over-temperature controller
- Inspect the installation site
Confirm the available space meets the external dimensions of 1220 × 616 × 1620 mm and the power supply is AC 220 V, 50 Hz with 1500 W capacity. - Install the incubator
Use suitable lifting equipment to position the unit upright in the designated location, ensuring chamber access is unobstructed. - Install shelves and optional accessories
Insert the two shelves per chamber and install any optional independent over-temperature controller if required. - Power on the system
Connect the power cable and switch on the unit, allowing each chamber to stabilize at the ambient temperature. - Set temperature parameters
Adjust each chamber's independent controller to the desired incubation temperature within the range of RT+5 to 65 °C.
How does the ±0.5°C temperature fluctuation across four independently controlled chambers affect reproducibility in parallel incubation experiments?
The ±0.5°C fluctuation per chamber is typical for forced-air incubators and supports reproducible parallel incubation when chambers are not opened frequently. The independent control prevents cross-contamination of temperature profiles, but users should validate uniformity within each chamber before critical assays, as the source specifies a temperature fluctuation of ±0.5°C and a resolution of 0.1°C across the range of RT+5 to 65°C.
Can the Four-Chamber Incubator accommodate 100 L samples per chamber while maintaining setpoint stability under variable ambient conditions?
Yes, each 100 L chamber is independently controlled and maintains stability within ±0.5°C fluctuation at ambient temperatures from +5 to +35°C. The 1500 W total power is distributed across chambers, so simultaneous operation of all four chambers at 65°C is supported, though rapid ambient temperature changes may affect recovery time. The working chamber dimensions are 455×430×510 mm per chamber.
What installation requirements should be considered for the 1220×616×1620 mm Four-Chamber Incubator?
The unit requires AC 220 V, 50 Hz power supply with 1500 W rated power and adequate clearance for door opening and ventilation. The external dimensions are 1220×616×1620 mm (W×D×H); ensure the floor can support the weight. The optional independent over-temperature controller should be specified at order if needed for unattended operation, as it is listed as an optional accessory.
The Four-Chamber Electric Heated Constant Temperature Incubator (100 L per chamber) provides four independently controlled stainless-steel chambers with temperature control from RT+5 to 65°C (fluctuation ±0.5°C), mirror-finish interiors, and optional over-temperature alarm, enabling parallel incubation workflows with sample separation.
Positive
- Independent chamber control: Each of the four chambers is independently controlled, allowing simultaneous incubation of different samples without cross-temperature interference, supporting separated sample management.
- Mirror-finish stainless steel interior: The inner chamber is constructed from mirror-finish stainless steel, which facilitates thorough cleaning and reduces the risk of contamination between runs.
Trade-offs
- Fixed AC 220V 50Hz power supply: The incubator requires AC 220 V, 50 Hz mains power; facilities with different voltage or frequency standards will need a step-down transformer or frequency converter, adding infrastructure cost.
- Limited ambient temperature range: The specified working ambient temperature range of +5 to +35°C restricts placement to climate-controlled laboratories; operation outside this range may impair temperature stability or trigger alarms.