Forced-Air Constant Temperature Incubator, 240 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This incubator requires a stable AC220V/50Hz power supply and must be positioned on a level surface with unobstructed airflow. The unit must be kept upright during transport and unloading to prevent internal damage.
- Power Supply Requirement: The incubator must be connected to a compatible AC220V/50Hz power supply as specified.
- Upright Transport Requirement: The unit must remain upright during unloading and positioning to avoid damage to internal components.
- Airflow Requirement: The air-circulation path must be kept unobstructed at all times to maintain temperature uniformity.
- Shelf Load Verification: Shelf load capacity must be verified before installation to prevent overloading.
This procedure describes the safe installation and initial operation of the Atomfair AF-DHP240C incubator. Follow these steps to ensure proper functionality and temperature uniformity.
- Position the Incubator
Unload and position the incubator upright on a level surface. - Connect Power
Connect the incubator to a compatible AC220V/50Hz power outlet. - Verify Configuration
Verify the shelf load capacity, chamber space, and shelf configuration before loading samples. - Ensure Airflow
Ensure the air-circulation path remains unobstructed during operation.
What temperature uniformity and fluctuation can I expect from the Atomfair AF-DHP240C forced-air incubator?
The AF-DHP240C maintains a temperature uniformity of ±1.5°C and fluctuation of ±0.5°C across the 240L chamber, as specified in the technical sheet. This is achieved through PID heating control and automatic three-speed fan adjustment that reduces energy use near setpoint and improves circulation uniformity.
What electrical and power specifications are required for the 240 L forced-air incubator?
The incubator requires a single-phase AC 220V/50Hz power supply with a 750 W input rating. Ensure the lab circuit can support this continuous load without overloading shared outlets. The external dimensions are 730 x 740 x 1170 mm, and the unit weighs 88 kg, so plan for a dedicated, grounded receptacle near the installation location.
What handling and installation precautions are necessary for the Atomfair 240 L incubator?
Before installation, verify shelf load capacity and ensure the 304 stainless-steel chamber’s internal dimensions of 450 x 600 x 900 mm provide adequate clearance for samples. Keep the air-circulation path unobstructed for uniform temperature distribution. The unit is shipped with reinforced packaging and must remain upright during unloading and positioning; avoid tilting to prevent damage to the internal circulation system.
The Atomfair AF-DHP240C forced-air incubator (240 L) combines a PID controller with automatic three-speed fan adjustment to balance uniformity and energy draw, while the 304 stainless-steel chamber and customizable shelf materials support routine cleaning and corrosion resistance in microbial culture and stability testing workflows.
Positive
- Automatic three-speed fan energy optimization: When the chamber approaches the target temperature, the controller automatically reduces fan speed, lowering energy consumption while maintaining circulation and uniformity.
- 304 stainless-steel interior for corrosion resistance: The 304 stainless-steel working chamber and optional 316 stainless-steel construction support routine cleaning and resist corrosion in humid incubation environments, extending service life.
Trade-offs
- Limited temperature range above ambient: The control range of RT+5 to 70 °C excludes low-temperature or near-ambient applications; cooling capability is absent, so the chamber cannot operate below 5 °C above room temperature.
- AC 220V/50 Hz power supply restricts global deployment: The unit requires AC220V/50Hz, limiting direct plug-and-play use in regions with 110 V or 60 Hz mains, likely requiring a voltage converter or step-down transformer.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).