Forced-Air Constant Temperature Incubator, 150 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires an unobstructed air-circulation path to maintain specified temperature uniformity of ±1.5°C. The unit must remain upright during unloading and positioning to prevent damage to the heating and circulation system.
- Temperature Uniformity Constraint: Temperature uniformity of ±1.5°C is maintained only when the air-circulation path is kept unobstructed.
- Transport Orientation Constraint: The unit must be kept upright during unloading and positioning to avoid compromising the internal heating and air-circulation system.
- Shelf Load Constraint: Shelf load capacity and chamber space must be verified before installation to prevent structural overload.
Position the incubator upright on a level surface with unobstructed ventilation around the unit. Verify power supply compatibility and shelf configuration before initial operation.
Required Equipment: Level surface, AC220V/50Hz power outlet
- Position the incubator
Place the incubator upright on a level, stable surface with at least 10 cm clearance around the unit for air circulation. - Connect power supply
Connect the unit to a dedicated AC220V/50Hz power outlet rated for at least 600 W input. - Configure shelves
Install the provided 3 shelves at desired spacing, ensuring they are securely seated on the support rails. - Set temperature parameters
Set the target temperature using the LCD controller, allowing the PID system to stabilize before loading samples. - Load samples
Place samples on the shelves, ensuring they do not block the internal air-circulation path. - Verify temperature uniformity
Allow the chamber to reach setpoint and confirm temperature uniformity using an independent calibrated thermometer.
How does the automatic three-speed fan control improve temperature uniformity and energy efficiency in the Atomfair AF-DHP150C forced-air incubator?
The automatic three-speed fan control reduces energy use when the chamber approaches the target temperature, helping to maintain uniform circulation and temperature uniformity. The PID heating controller further supports stable setpoint tracking and quicker recovery after door openings. The chamber achieves a temperature uniformity of ±1.5°C and fluctuation of ±0.5°C.
Can the Atomfair AF-DHP150C incubator be customized for use with corrosive samples or high-humidity applications?
Yes, the incubator supports customization with 316 stainless steel for the chamber and shelves, which offers enhanced corrosion resistance compared to the standard 304 stainless steel. Additionally, perforated or non-perforated shelf options can be specified to match different sample types and airflow requirements. The standard 304 stainless steel chamber is already corrosion-resistant and easy to clean for routine laboratory use.
What are the installation and power requirements for the Atomfair AF-DHP150C forced-air incubator?
The incubator requires a power supply of AC220V/50Hz with an input power of 600 W. It has an external footprint of 680 x 640 x 1020 mm and weighs 67 kg. For optimal temperature uniformity, keep the air-circulation path unobstructed. The unit should be kept upright during transport and positioning. The timer range is 1 min to 9999 h 59 min, suitable for extended experiments.
The AF-LE-E-DHPC-0150-9155 Forced-Air Constant Temperature Incubator (150 L) provides a RT+5 to 70 °C range with ±1.5 °C uniformity and ±0.5 °C fluctuation, supported by PID heating and automatic three-speed fan control for stable culture conditions. Its 304 stainless-steel chamber and customizable 316 stainless-steel or perforated shelf options offer corrosion resistance and flexibility, though the powder-coated exterior and 220 V/50 Hz power requirement introduce placement and infrastructure constraints.
Positive
- PID heating with auto three-speed fan: The PID controller and automatic three-speed fan adjustment reduce energy consumption near setpoint and improve temperature uniformity for microbial culture and stability testing.
- Corrosion-resistant 304 SS chamber: 304 stainless-steel interior and customizable 316 stainless-steel or perforated/non-perforated shelves simplify cleaning and support demanding laboratory environments with longer service life.
Trade-offs
- Power supply and voltage specific: The unit requires AC 220 V/50 Hz input, which may necessitate a step-down transformer or dedicated circuit in regions using 110 V or 60 Hz mains, adding infrastructure cost before deployment.
- Powder-coated steel exterior susceptibility: The cold-rolled steel outer shell with powder coating is less resistant to chemical spills or high-humidity environments than a stainless-steel cabinet, requiring careful lab placement and spill management.