875 L Dual-Flow Nitrogen ESD Cabinet 1%-60% RH ATOMFAIR®

$2,400.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

875 L anti-static dual-flow nitrogen cabinet with 1%-60% RH control, 900 × 600 × 1850 mm body, 5 shelves and 15-50 L/min recovery flow. Order now.

SKU: AF-EI-E-DFNC-ESD0-875L
Category:
Brands:

875L Dual-Flow Energy-Saving Nitrogen Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 875 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 900 × 600 × 1850 mm, inner dimensions of 855 × 550 × 1670 mm and 5 adjustable shelves.

This dual-flow energy-saving nitrogen cabinet is designed for low-humidity storage tasks where fast recovery after door opening and reduced unnecessary gas consumption are both important. It supports moisture-sensitive materials that require controlled nitrogen-assisted drying while improving atmosphere recovery and lowering routine nitrogen demand.

Typical application areas include research laboratories, electronics workshops, component staging rooms, optical storage spaces and inspection environments where cabinet doors may be opened more frequently during routine work. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, dual-flow nitrogen management, automatic switching between large-flow and small-flow operation, tempered-glass viewing areas and perforated adjustable shelves for stable day-to-day cabinet performance.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-DFNC875F
Product Family Dual-Flow Energy-Saving Nitrogen Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 875 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 900 × 600 × 1850 mm
Inner Dimensions (W × D × H) 855 × 550 × 1670 mm
Adjustable Shelf Quantity 5
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Automatic software-controlled nitrogen management
Large-Flow Meter Setting 15-50 L/min
Small-Flow Meter Setting 1-5 L/min
Switching Logic Automatic switching between large-flow and small-flow operation
Operating Characteristic Fast recovery after door opening with reduced unnecessary nitrogen use
Suitable Stored Materials Moisture-sensitive electronic parts, optical components and frequently accessed laboratory materials

Key Features and Advantages

  • Dual-flow nitrogen control with large-flow settings of 15-50 L/min and small-flow settings of 1-5 L/min.
  • Automatic switching between high-flow and low-flow operation without manual intervention.
  • Fast recovery after door opening helps restore the cabinet atmosphere while reducing unnecessary nitrogen consumption.
  • Sealed galvanized steel cabinet structure with tempered-glass viewing areas for controlled dry storage.
  • Perforated adjustable shelves support airflow circulation and flexible material arrangement.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, component staging rooms, optical storage spaces and inspection environments that require low-humidity nitrogen-assisted storage with rapid recovery after cabinet access.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 5 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet requires a stable indoor surface, level installation, and proper door sealing to maintain low-humidity conditions. Nitrogen gas supply must be stable and connected with automatic switching between large-flow and small-flow settings.

  • Electrostatic Discharge Protection: The anti-static cabinet body and exterior coating prevent electrostatic discharge damage to sensitive components during storage.
  • Humidity Recovery: The dual-flow nitrogen management ensures fast humidity recovery after door opening while reducing unnecessary nitrogen consumption.
  • Shelf Loading: Distribute stored items evenly across the 5 adjustable perforated shelves to ensure proper airflow circulation and avoid overloading.
  • Gas Supply Stability: Verify stable gas-supply conditions before operation to ensure the automatic switching logic functions correctly.
  • Sealing Integrity: Protect the magnetic sealing and tempered-glass viewing doors during movement to prevent leakage and humidity ingress.

These steps guide the installation, gas connection, and initial operation of the nitrogen cabinet. Proper setup ensures fast humidity recovery and efficient nitrogen usage.

Required Equipment: Nitrogen gas supply line, Leveling tool

  1. Inspect and Unpack
    Inspect the cabinet after delivery for any visible damage and verify that all components are intact.
  2. Install on Stable Surface
    Install the cabinet on a stable indoor surface that is level and capable of supporting its weight.
  3. Verify Leveling and Door Sealing
    Verify that the cabinet is level using a leveling tool and confirm that the door seals properly against the frame.
  4. Connect Nitrogen Supply
    Connect a stable nitrogen gas supply to the cabinet's inlet, ensuring the flow meters are set within the specified ranges.
  5. Confirm Utility Conditions
    Confirm that both power and gas connections are properly established before formal operation.
  6. Load Materials Evenly
    Distribute moisture-sensitive materials evenly across the 5 adjustable perforated shelves, leaving space for airflow circulation.
  7. Close and Monitor
    Close the cabinet door securely and monitor the humidity display to confirm the setpoint is reached and maintained.

How does the dual-flow nitrogen management system balance fast humidity recovery with nitrogen consumption in the 875L cabinet?

The dual-flow system automatically switches between a large-flow setting of 15-50 L/min for rapid recovery after door opening and a small-flow setting of 1-5 L/min for maintenance. This reduces unnecessary nitrogen consumption while ensuring fast atmosphere restoration, as stated in the product specifications.

Can the 875L dual-flow nitrogen cabinet be integrated with an existing nitrogen supply or generator, and what are the interface requirements?

Yes, the cabinet supports connection to an external nitrogen supply. Optional items include a nitrogen generator configuration for on-site nitrogen, and an RS485 communication interface for PC-side monitoring. The cabinet requires stable gas-supply conditions before operation, as noted in the handling instructions.

What are the installation and handling requirements for the 875L anti-static nitrogen cabinet to ensure proper operation and safety?

Install the cabinet on a stable indoor surface, keep the door closed during normal use, and distribute stored items evenly across the 5 adjustable shelves. Protect structural and sealing components during movement, and use reinforced wooden-crate packaging for shipment. Verify stable gas-supply conditions before operation, and ensure level installation and door sealing after delivery.

This 875 L dual-flow nitrogen cabinet features an anti-static body and automatic flow switching for efficient low-humidity storage of ESD-sensitive materials, with fast recovery and reduced nitrogen use, but requires a stable external gas supply and careful site planning.

Positive

  • Dual-flow automatic nitrogen switching: The cabinet automatically switches between large-flow (15-50 L/min) and small-flow (1-5 L/min) to enable fast atmosphere recovery after door openings while reducing unnecessary nitrogen consumption.
  • Anti-static cabinet for ESD safety: The anti-static exterior coating and galvanized steel construction provide electrostatic discharge protection, making it suitable for handling sensitive electronic and optical components in controlled environments.

Trade-offs

  • Requires external nitrogen gas supply: The cabinet depends on a stable external nitrogen source; users must verify gas-supply conditions before operation, adding infrastructure requirements and ongoing consumable costs.
  • Large footprint and handling precautions: With outer dimensions of 900×600×1850 mm and a capacity of 875 L, the cabinet requires significant floor space and a stable surface; shipping and movement require reinforced wooden-crate packaging, indicating substantial weight.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).