Constant Temperature Incubator AF-PTIN-600 80°C ATOMFAIR®

$2,200.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Programmable constant temperature incubator with a 600 × 450 × 900 mm chamber, RT + 5 to 80 °C range, 600 W power and 0.1 °C resolution. Order now.

SKU: AF-LE-E-PTIN-9272-9272
Category:
Brands:

Precision Constant Temperature Incubator, 600 × 450 × 900 mm chamber with Programmable Control
Research-grade laboratory product
Product Overview

Precision Constant Temperature Incubator, 600 × 450 × 900 mm chamber with Programmable Control is designed for precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows. Precision temperature control, programmable operation, and fan speed management for stable constant temperature experiments. The configuration provides RT + 5 to 80 °C, 600 W rated power, a working chamber of 600 × 450 × 900 mm (W × D × H), and external dimensions of 755 × 785 × 1130 mm (W × D × H).

The control and chamber design support practical laboratory operation: Large-screen LCD controller with programmable operation. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Programmable controller; printer; U-disk data storage; RS485 interface; UV sterilization; independent over-temperature controller.

This equipment is suited to laboratories that need precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-PTIN-600
Product Family Precision Constant Temperature Incubator
Configuration 600 × 450 × 900 mm chamber
Rated Operating Power 600 W
Working Chamber Size 600 × 450 × 900 mm (W × D × H)
Overall Dimensions 755 × 785 × 1130 mm (W × D × H)
Temperature Control Range RT + 5 to 80 °C
Temperature Resolution / Fluctuation 0.1 °C / ±0.2 °C
Temperature Uniformity ±1.5 °C at 37 °C
Working Ambient Temperature +5 to +35 °C
Power Supply AC 220 V, 50 Hz
Controller Large-screen LCD controller with programmable operation
Standard Shelves 2 shelves
Data Handling Optional U-disk, RS485, printer, and UV sterilization
Optional Accessories and Functions Programmable controller; printer; U-disk data storage; RS485 interface; UV sterilization; independent over-temperature controller
Performance Features
  • A programmable controller supports multi-step operation for complex temperature control processes. This makes real-time parameter review and routine operation easier in precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows.
  • Automatic circulation fan speed control helps balance chamber uniformity and sample protection. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A stainless-steel inner chamber and rounded internal corners support cleaning and maintenance. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • This product family includes self-diagnosis support for fault identification on the LCD screen. This makes real-time parameter review and routine operation easier in precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows.
  • Optional printer, communication, and U-disk storage accessories support operating record management. This allows the configuration to match documentation, communication and monitoring needs in precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows.
  • Independent over-temperature alarm protection supports safer experimental operation. This helps operators identify abnormal conditions during unattended or extended precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows.
APPLICATION SCOPE: Suitable for precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 755 × 785 × 1130 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Programmable controller; printer; U-disk data storage; RS485 interface; UV sterilization; independent over-temperature controller. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator must be operated within an ambient temperature range of 5 to 35°C and connected to a grounded AC 220V 50Hz power supply. The chamber temperature must not exceed 80°C, and the unit should be kept upright during transport and installed with adequate clearance for ventilation and access.

  • Ambient Temperature: Operate the incubator only in an ambient temperature between +5 and +35°C to maintain specified performance.
  • Electrical Supply: Connect the incubator to a grounded AC 220V 50Hz power outlet with sufficient capacity for the 600W rated power.
  • Temperature Limit: Do not set the chamber temperature above 80°C to avoid damage to the unit and samples.
  • Transport and Installation: Keep the incubator upright during transport and use suitable lifting equipment to prevent impact damage.
  • Safety Over-Temperature: Install the optional independent over-temperature controller for unattended operation to guard against overheating.

Follow these steps to safely install the incubator, set up the power supply, and configure the programmable controller. Proper installation ensures accurate temperature control and safe operation.

Required Equipment: Lifting equipment

  1. Transport Preparation
    Keep the packed incubator upright and use suitable lifting equipment to move it to the installation site.
  2. Site Confirmation
    Confirm that the installation space accommodates the 755 × 785 × 1130 mm external dimensions and that a grounded AC 220V 50Hz power outlet is available.
  3. Unpacking
    Unpack the incubator carefully, ensuring the unit remains upright and protected from impact.
  4. Power Connection
    Connect the incubator to the grounded power supply as specified in the technical data.
  5. Chamber Access
    Position the incubator so that the chamber, sensors, shelves, filters, doors, and control interfaces remain accessible for cleaning and operation.
  6. Optional Accessories
    Select and install any optional accessories such as printer, U-disk data storage, or UV sterilization according to the required workflow.

How does the automatic circulation fan speed control balance uniformity and sample protection in this 600 × 450 × 900 mm incubator?

The fan speed control actively adjusts airflow to maintain chamber uniformity while minimizing direct air velocity on sensitive samples. At 37 °C, temperature uniformity is specified at ±1.5 °C, and temperature fluctuation at ±0.2 °C, providing stable conditions for cultivation and holding protocols without compromising sample integrity.

Can this Precision Constant Temperature Incubator be integrated with external data logging or monitoring systems?

Yes, the incubator supports optional RS485 interface for external communication, as well as optional printer and U-disk data storage for record management. These accessories enable integration with laboratory monitoring or documentation workflows, but must be selected at time of order as they are not included in the base configuration.

What are the infrastructure requirements for installing this 600 W incubator with 755 × 785 × 1130 mm external dimensions?

The unit requires an AC 220 V, 50 Hz power supply and a working ambient temperature range of +5 to +35 °C. Before installation, confirm floor or bench space accommodates the 755 × 785 × 1130 mm (W × D × H) footprint and that the chamber, sensors, and control interfaces remain accessible for cleaning and operation. The independent over-temperature alarm adds a safety layer for unattended use.

The Precision Constant Temperature Incubator (AF-PTIN-600) provides programmable temperature control from RT+5 to 80°C with ±0.2°C fluctuation and ±1.5°C uniformity at 37°C, featuring a stainless steel chamber and automatic fan speed control, but requires optional accessories for data logging and UV sterilization, and operates within a limited ambient temperature range of +5 to +35°C.

Positive

  • Programmable Multi-Step Controller: Supports multi-step operation for complex temperature control processes, enabling real-time parameter review and routine operation.
  • Stainless Steel Chamber with Rounded Corners: Facilitates easy cleaning and maintenance, supporting repeated cleaning and sample organization.

Trade-offs

  • Ambient Temperature Sensitivity: The incubator is specified for operation within +5 to +35°C ambient; performance may degrade outside this range.
  • Optional Data Logging and Sterilization: Printer, U-disk storage, RS485, and UV sterilization are optional; standard configuration does not include data recording or sterilization functions.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).