Professional Constant Temperature and Humidity Chamber, 80 L,with Printer
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires a dedicated power supply of 2000 W at AC 220 V, 50 Hz and must be operated in an environment between +5 and 35°C. The unit must be kept upright during transport and positioned with adequate clearance for all service points.
- Power Supply Constraint: Connect the chamber only to a dedicated AC 220 V, 50 Hz power source rated for 2000 W.
- Operating Environment Constraint: Maintain the ambient temperature between +5 and 35°C to prevent condensation and ensure stable humidity control.
- Orientation Constraint: Always transport and position the chamber in an upright orientation to avoid compressor damage.
- Clearance Constraint: Keep air inlets, test ports, shelving, drain areas, doors, and controller surfaces accessible for routine cleaning and maintenance.
Follow these steps to unpack, position, and power on the chamber for the first time. Ensure that all installation space and power requirements are met before operation.
Required Equipment: Lifting equipment
- Inspect packaging
Inspect the chamber packaging for damage and keep the unit upright during transport to prevent compressor oil migration. - Position chamber
Position the chamber in the installation space, maintaining accessible clearance around air inlets, test ports, shelving, drain areas, doors, and controller surfaces. - Connect power
Connect the chamber to a dedicated AC 220 V, 50 Hz power supply rated for 2000 W. - Set environment
Set the operating environment temperature between +5 and 35°C to ensure stable chamber performance.
What is the temperature stability specification for the LHS-80HC-II at high versus low temperature setpoints?
At high temperature ranges, the chamber achieves a temperature fluctuation/uniformity of ±0.5°C, while at low temperature ranges it is ±1°C. This difference is stated in the technical specifications for the LHS-80HC-II model, which covers a full control range of 10 to 70°C.
Can the Atomfair AF-LH20180 constant temperature and humidity chamber be connected to a laboratory data acquisition system for remote monitoring?
Yes, the chamber supports optional RS232/485 communication interface and software, which enables data output and integration with external monitoring systems. Additionally, a side test port is provided for external probe access during chamber verification or method development.
What are the electrical and spatial installation requirements for the 80L professional constant temperature and humidity chamber?
The chamber requires an AC 220V, 50 Hz power supply with a 2000 W capacity. Its external dimensions are 550 x 790 x 1080 mm, and it must be operated in an ambient environment of +5 to 35°C. Installation planning should keep air inlets, test ports, shelving, drain areas, doors, and controller surfaces accessible for cleaning and maintenance.
The Professional Constant Temperature and Humidity Chamber (80 L, with Printer) offers reliable balancing humidity control from 40% to 95% RH and temperature range of 10 to 70°C, with an imported compressor and humidity sensor. Its mirror-finish stainless steel interior and side test port support cleaning and external probe access, but the 2000 W power requirement and ±3%RH humidity deviation impose operational constraints.
Positive
- Balancing temperature-humidity control: Microcomputer balancing control logic maintains stable temperature and humidity conditions, critical for repeatable environmental testing in incubation, cultivation, and stability studies.
- Imported compressor and humidity sensor: Reliable performance from imported compressor, fan, and humidity sensor components supports long-duration laboratory schedules and consistent chamber operation.
Trade-offs
- High power requirement (2000 W): The chamber requires 2000 W at 220 V, 50 Hz, necessitating appropriate electrical infrastructure and circuit capacity in the lab.
- Humidity deviation ±3%RH: The specified humidity deviation of ±3%RH may limit suitability for applications requiring tighter humidity accuracy, such as certain pharmaceutical stability tests.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).