CO2 Incubator 40 L Touchscreen 90 °C Sterilization ATOMFAIR®

$7,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

40 L gas-jacket CO2 incubator with 90 °C sterilization, 350 W power, touchscreen control, 0-20% CO2 range and ±0.3 °C uniformity for cell culture. Order now.

SKU: AF-LE-E-RHRW-0040-40RH
Category:
Brands:

40 L Gas-Jacket 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series
Research-grade laboratory product
Product Overview

40 L Gas-Jacket 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series is designed for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows. Touchscreen trend charts, CO2 control with optional O2 monitoring, and sterilization variants for advanced culture workflows. The configuration provides RT + 3 to 55 °C, 350 W rated power, a working chamber of 400 × 286 × 350 mm (W × D × H), and external dimensions of 590 × 440 × 576 mm (W × D × H).

The control and chamber design support practical laboratory operation: Large touchscreen interface with curve display and record review. laboratory chamber construction The model includes 2 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching.

This equipment is suited to laboratories that need advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2H-040G
Product Family CO2 Incubator, High-End Touchscreen Series
Configuration 40 L Gas-Jacket 90 °C Sterilization
Rated Operating Power 350 W
Working Chamber Size 400 × 286 × 350 mm (W × D × H)
Overall Dimensions 590 × 440 × 576 mm (W × D × H)
Shelf Configuration 2 shelves
Power Supply AC 220 V, 50 Hz
Temperature Control Range RT + 3 to 55 °C
Working Ambient Temperature +5 to +30 °C
Temperature Uniformity ±0.3 °C at 37 °C
Temperature Stability ±0.1 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
O2 Option Optional zirconia O2 control from 1% to 90%
Relative Humidity Natural evaporation, 90% or higher, with optional humidity display
Controller Large touchscreen interface with curve display and record review
Optional Accessories and Functions Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching
Performance Features
  • The touchscreen controller supports trend curves, alarm review, and 72-hour running record lookup according to the product design. This makes real-time parameter review and routine operation easier in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Infrared CO2 sensing and optional O2 control support advanced gas-environment culture workflows. This allows the configuration to match documentation, communication and monitoring needs in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • RHP models use 90 °C high-temperature and high-humidity sterilization, while selected RWP(90) models add UV and 90 °C sterilization support. This supports chamber hygiene and contamination-control routines for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • An environmental temperature monitoring system and heated outer door support stable chamber control and reduced condensation. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Optional wireless alarm, account permissions, external temperature and CO2 monitoring, and automatic cylinder switching are listed. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Alarm coverage includes power failure, CO2 deviation, door opening, and multiple temperature sensor conditions. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
APPLICATION SCOPE: Suitable for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 590 × 440 × 576 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This incubator requires a dedicated AC 220V, 50Hz power supply and an ambient temperature between 5°C and 30°C. The chamber, sensors, and doors must remain accessible for cleaning and inspection to maintain safe operation.

  • Power Supply Constraint: The incubator must be connected to a 220V, 50Hz power outlet with a rated capacity of at least 350W.
  • Ambient Temperature Constraint: Operate the incubator only within an ambient temperature range of +5°C to +30°C to ensure stable performance.
  • Accessibility Constraint: Keep the chamber, sensors, shelves, filters, doors, test ports, and control interfaces accessible for cleaning, inspection, and operation.

Confirm the installation space and power supply before unpacking. After positioning, verify accessibility and configure the incubator settings.

  1. Confirm Installation Requirements
    Confirm that the available space accommodates the 590x440x576 mm external dimensions and that a 220V, 50Hz power outlet is available.
  2. Transport the Packed Unit
    Keep the packed unit upright and use suitable lifting equipment during transport to prevent damage.
  3. Unpack and Position the Incubator
    Unpack the incubator and place it on a level surface, ensuring the chamber doors are unobstructed.
  4. Verify Accessibility and Power Connection
    Ensure the chamber, sensors, doors, and control interfaces are accessible, then connect the power cord and switch on the unit.

What is the CO2 recovery time after a door opening, and how does the gas-jacket design contribute to environmental stability?

The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, as specified in the technical data. The gas-jacket design, combined with the heated outer door and environmental temperature monitoring system, supports stable chamber conditions and reduces condensation, which is critical for maintaining consistent incubation environments during routine sample access.

Can this incubator support hypoxic or hyperoxic cell culture conditions via O2 control?

Yes, the incubator offers an optional zirconia O2 control system that can regulate oxygen from 1% to 90%, enabling both hypoxic and hyperoxic culture workflows. This feature is listed as an optional accessory, so the unit must be ordered with the O2 control module to support oxygen-managed cultivation.

What sterilization method is used for chamber decontamination, and is UV sterilization available on this model?

This model uses 90 °C high-temperature and high-humidity sterilization for chamber decontamination, as indicated by the product name and specifications. UV sterilization is not standard on this 40 L Gas-Jacket 90 °C Sterilization model; it is available only on selected RWP(90) models that also include 90 °C sterilization. Users requiring UV should consider the appropriate RWP variant.

This 40 L gas-jacket CO2 incubator delivers precise temperature uniformity (±0.3°C) and stability (±0.1°C) with rapid CO2 recovery (<3 min to 5% after door opening), plus 90 °C sterilization for contamination control, but requires 220 V, 50 Hz power and a limited ambient temperature range of +5 to +30 °C for proper operation.

Positive

  • High temperature uniformity and stability: Maintains ±0.3 °C uniformity and ±0.1 °C stability at 37 °C, ensuring reproducible incubation conditions for sensitive cell cultures.
  • Rapid CO2 recovery after door opening: Recovers to 5% CO2 within 3 minutes after a 30-second door opening, minimizing environmental disruption during sample access.

Trade-offs

  • Fixed 220 V AC power requirement: Operates exclusively on AC 220 V, 50 Hz, which may necessitate voltage conversion or dedicated power infrastructure in laboratories with different mains standards.
  • Limited working ambient temperature range: Requires ambient temperature between +5 and +30 °C, which may restrict placement in unconditioned lab spaces or hot environments.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).