40 L Gas-Jacket 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This incubator requires a dedicated AC 220V, 50Hz power supply and an ambient temperature between 5°C and 30°C. The chamber, sensors, and doors must remain accessible for cleaning and inspection to maintain safe operation.
- Power Supply Constraint: The incubator must be connected to a 220V, 50Hz power outlet with a rated capacity of at least 350W.
- Ambient Temperature Constraint: Operate the incubator only within an ambient temperature range of +5°C to +30°C to ensure stable performance.
- Accessibility Constraint: Keep the chamber, sensors, shelves, filters, doors, test ports, and control interfaces accessible for cleaning, inspection, and operation.
Confirm the installation space and power supply before unpacking. After positioning, verify accessibility and configure the incubator settings.
- Confirm Installation Requirements
Confirm that the available space accommodates the 590x440x576 mm external dimensions and that a 220V, 50Hz power outlet is available. - Transport the Packed Unit
Keep the packed unit upright and use suitable lifting equipment during transport to prevent damage. - Unpack and Position the Incubator
Unpack the incubator and place it on a level surface, ensuring the chamber doors are unobstructed. - Verify Accessibility and Power Connection
Ensure the chamber, sensors, doors, and control interfaces are accessible, then connect the power cord and switch on the unit.
What is the CO2 recovery time after a door opening, and how does the gas-jacket design contribute to environmental stability?
The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, as specified in the technical data. The gas-jacket design, combined with the heated outer door and environmental temperature monitoring system, supports stable chamber conditions and reduces condensation, which is critical for maintaining consistent incubation environments during routine sample access.
Can this incubator support hypoxic or hyperoxic cell culture conditions via O2 control?
Yes, the incubator offers an optional zirconia O2 control system that can regulate oxygen from 1% to 90%, enabling both hypoxic and hyperoxic culture workflows. This feature is listed as an optional accessory, so the unit must be ordered with the O2 control module to support oxygen-managed cultivation.
What sterilization method is used for chamber decontamination, and is UV sterilization available on this model?
This model uses 90 °C high-temperature and high-humidity sterilization for chamber decontamination, as indicated by the product name and specifications. UV sterilization is not standard on this 40 L Gas-Jacket 90 °C Sterilization model; it is available only on selected RWP(90) models that also include 90 °C sterilization. Users requiring UV should consider the appropriate RWP variant.
This 40 L gas-jacket CO2 incubator delivers precise temperature uniformity (±0.3°C) and stability (±0.1°C) with rapid CO2 recovery (<3 min to 5% after door opening), plus 90 °C sterilization for contamination control, but requires 220 V, 50 Hz power and a limited ambient temperature range of +5 to +30 °C for proper operation.
Positive
- High temperature uniformity and stability: Maintains ±0.3 °C uniformity and ±0.1 °C stability at 37 °C, ensuring reproducible incubation conditions for sensitive cell cultures.
- Rapid CO2 recovery after door opening: Recovers to 5% CO2 within 3 minutes after a 30-second door opening, minimizing environmental disruption during sample access.
Trade-offs
- Fixed 220 V AC power requirement: Operates exclusively on AC 220 V, 50 Hz, which may necessitate voltage conversion or dedicated power infrastructure in laboratories with different mains standards.
- Limited working ambient temperature range: Requires ambient temperature between +5 and +30 °C, which may restrict placement in unconditioned lab spaces or hot environments.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).