CO2 Incubator 240 L AF-CO2C-240 ATOMFAIR®

$7,900.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

240 L CO2 incubator with IR sensing, 0 to 20% CO2 control, RT+3 to 55 °C range, 90 °C sterilization, 3 shelves. ATOMFAIR®

SKU: AF-LE-E-CRHC-0240-24CR
Category:
Brands:

240 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control
Research-grade laboratory product
Product Overview

240 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control is designed for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows. Infrared CO2 sensing, 90 °C sterilization, high humidity cell culture support, and recovery-focused chamber design. The configuration provides RT + 3 to 55 °C, 950 W rated power, a working chamber of 600 × 630 × 670 mm (W × D × H), and external dimensions of 788 × 837 × 940 mm (W × D × H).

The control and chamber design support practical laboratory operation: laboratory controller. laboratory chamber construction The model includes 3 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable.

This equipment is suited to laboratories that need cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2C-240
Product Family CO2 Incubator, Professional Cell Culture Series
Configuration 240 L
Rated Operating Power 950 W
Working Chamber Size 600 × 630 × 670 mm (W × D × H)
Overall Dimensions 788 × 837 × 940 mm (W × D × H)
Shelf Configuration 3 shelves
Power Supply AC 220 V, 50 Hz
Heating Method Gas-jacket microcomputer PID control
Temperature Control Range RT + 3 to 55 °C
Working Ambient Temperature +5 to +30 °C
Temperature Uniformity ±0.3 °C at 37 °C
Temperature Stability ±0.1 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
Temperature Recovery Time No more than 8 minutes to recover to 37 °C after a 30-second door opening
Relative Humidity Natural evaporation, 90% or higher, with optional humidity display
Sterilization 90 °C high-temperature and high-humidity sterilization
Optional Accessories and Functions HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable
Performance Features
  • Infrared CO2 sensing supports stable CO2 control and faster recovery in frequent door-opening workflows. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • A 90 °C high-temperature and high-humidity sterilization cycle can treat the chamber and internal components. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Microbial filtration at the CO2 inlet and optional HEPA filtration support cleaner chamber conditions. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • Door heating reduces condensation on the inner glass door and supports cleaner cell culture operation. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • An LCD display, stackable cabinet design, and data export options support day-to-day laboratory use. This makes real-time parameter review and routine operation easier in cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • Alarms cover over-temperature, CO2 deviation, and prolonged door opening according to the product design. This helps operators identify abnormal conditions during unattended or extended cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
APPLICATION SCOPE: Suitable for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 788 × 837 × 940 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a stable AC 220 V, 50 Hz power supply and an ambient temperature range of +5 to +30 °C. The 90 °C high-temperature sterilization cycle must be used for decontamination, and alarms monitor over-temperature, CO2 deviation, and prolonged door opening.

  • Power Supply Requirement: Power supply must be AC 220 V, 50 Hz with sufficient capacity for 950 W rated power.
  • Ambient Temperature Constraint: Ambient operating temperature must remain between +5 and +30 °C to maintain specified performance.
  • Sterilization Protocol: The 90 °C sterilization cycle is required for chamber decontamination before contamination-sensitive use.
  • Alarm Monitoring: Alarms automatically alert for over-temperature, CO2 deviation, and prolonged door opening conditions.
  • Transport Handling: During transport, the unit must be kept upright and protected from impact using reinforced packaging.

Follow these steps to install and initialize the incubator for cell culture workflows. Confirm space and power, position upright, and verify system functions before use.

Required Equipment: Suitable lifting equipment

  1. Confirm Installation Space and Power
    Confirm that the installation space accommodates the 788 × 837 × 940 mm external dimensions and that a 220 V, 50 Hz power supply is available.
  2. Position Incubator Upright
    Position the packed incubator upright and use suitable lifting equipment to move it to the installation site.
  3. Unpack and Ensure Accessibility
    Unpack the incubator and ensure the chamber, sensors, shelves, filters, doors, test ports, and control interfaces remain accessible.
  4. Connect Power and Verify Display
    Connect the power supply and verify the LCD display shows correct parameters and alarm functions are operational.

How does the infrared CO2 sensor improve recovery time compared to traditional thermal conductivity sensors?

The infrared CO2 sensor enables faster recovery by being less affected by humidity and temperature shifts. The product specifies a CO2 recovery time of no more than 3 minutes to return to 5% CO2 after a 30-second door opening, supporting stable control in frequent door-opening workflows.

What are the installation requirements for the 240 L CO2 incubator regarding power supply and ambient conditions?

The incubator requires an AC 220 V, 50 Hz power supply and an ambient temperature range of +5 to +30 °C. External dimensions are 788 × 837 × 940 mm (W × D × H), so the installation space must accommodate these dimensions and allow for proper ventilation and access.

What sterilization method does this incubator use and how does it support contamination-sensitive cell culture?

The incubator uses a 90 °C high-temperature and high-humidity sterilization cycle that treats the chamber and internal components. This, combined with microbial filtration at the CO2 inlet and optional HEPA filtration, helps maintain cleaner chamber conditions for contamination-sensitive cultivation workflows.

This 240 L CO2 incubator with infrared CO2 sensing and gas-jacket heating provides stable temperature (±0.1°C) and fast CO2 recovery (≤3 min to 5% after 30 s door opening), with a 90°C sterilization cycle. It is suitable for cell culture workflows but requires a 220 V/50 Hz power supply and controlled ambient temperature (5–30 °C).

Positive

  • Infrared CO2 sensing with fast recovery: CO2 recovery to 5% in ≤3 minutes after a 30-second door opening, enabling stable conditions during frequent access in cell culture workflows.
  • 90°C high-temperature sterilization cycle: High-temperature and high-humidity sterilization treats the chamber and internal components, supporting decontamination between cultures without chemical agents.

Trade-offs

  • Requires 220 V, 50 Hz power supply: The incubator is designed for AC 220 V, 50 Hz electrical systems, which may require a voltage converter or dedicated line in regions with different mains standards.
  • Limited ambient operating temperature range: The working ambient temperature must be +5 to +30 °C, restricting placement to climate-controlled laboratory spaces without significant thermal gradients.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).