240 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a stable AC 220 V, 50 Hz power supply and an ambient temperature range of +5 to +30 °C. The 90 °C high-temperature sterilization cycle must be used for decontamination, and alarms monitor over-temperature, CO2 deviation, and prolonged door opening.
- Power Supply Requirement: Power supply must be AC 220 V, 50 Hz with sufficient capacity for 950 W rated power.
- Ambient Temperature Constraint: Ambient operating temperature must remain between +5 and +30 °C to maintain specified performance.
- Sterilization Protocol: The 90 °C sterilization cycle is required for chamber decontamination before contamination-sensitive use.
- Alarm Monitoring: Alarms automatically alert for over-temperature, CO2 deviation, and prolonged door opening conditions.
- Transport Handling: During transport, the unit must be kept upright and protected from impact using reinforced packaging.
Follow these steps to install and initialize the incubator for cell culture workflows. Confirm space and power, position upright, and verify system functions before use.
Required Equipment: Suitable lifting equipment
- Confirm Installation Space and Power
Confirm that the installation space accommodates the 788 × 837 × 940 mm external dimensions and that a 220 V, 50 Hz power supply is available. - Position Incubator Upright
Position the packed incubator upright and use suitable lifting equipment to move it to the installation site. - Unpack and Ensure Accessibility
Unpack the incubator and ensure the chamber, sensors, shelves, filters, doors, test ports, and control interfaces remain accessible. - Connect Power and Verify Display
Connect the power supply and verify the LCD display shows correct parameters and alarm functions are operational.
How does the infrared CO2 sensor improve recovery time compared to traditional thermal conductivity sensors?
The infrared CO2 sensor enables faster recovery by being less affected by humidity and temperature shifts. The product specifies a CO2 recovery time of no more than 3 minutes to return to 5% CO2 after a 30-second door opening, supporting stable control in frequent door-opening workflows.
What are the installation requirements for the 240 L CO2 incubator regarding power supply and ambient conditions?
The incubator requires an AC 220 V, 50 Hz power supply and an ambient temperature range of +5 to +30 °C. External dimensions are 788 × 837 × 940 mm (W × D × H), so the installation space must accommodate these dimensions and allow for proper ventilation and access.
What sterilization method does this incubator use and how does it support contamination-sensitive cell culture?
The incubator uses a 90 °C high-temperature and high-humidity sterilization cycle that treats the chamber and internal components. This, combined with microbial filtration at the CO2 inlet and optional HEPA filtration, helps maintain cleaner chamber conditions for contamination-sensitive cultivation workflows.
This 240 L CO2 incubator with infrared CO2 sensing and gas-jacket heating provides stable temperature (±0.1°C) and fast CO2 recovery (≤3 min to 5% after 30 s door opening), with a 90°C sterilization cycle. It is suitable for cell culture workflows but requires a 220 V/50 Hz power supply and controlled ambient temperature (5–30 °C).
Positive
- Infrared CO2 sensing with fast recovery: CO2 recovery to 5% in ≤3 minutes after a 30-second door opening, enabling stable conditions during frequent access in cell culture workflows.
- 90°C high-temperature sterilization cycle: High-temperature and high-humidity sterilization treats the chamber and internal components, supporting decontamination between cultures without chemical agents.
Trade-offs
- Requires 220 V, 50 Hz power supply: The incubator is designed for AC 220 V, 50 Hz electrical systems, which may require a voltage converter or dedicated line in regions with different mains standards.
- Limited ambient operating temperature range: The working ambient temperature must be +5 to +30 °C, restricting placement to climate-controlled laboratory spaces without significant thermal gradients.