Programmable Humidity Chamber 100 L -40 to 100 °C ATOMFAIR®

$14,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

100 L programmable humidity chamber with -40 to 100 °C control, 35-95%RH humidity, 0.1 °C resolution, touchscreen programs and 304 stainless interior.

SKU: AF-LE-E-BPSC-0100-CB10
Category:
Brands:

Programmable Touchscreen Constant Temperature and Humidity Chamber, 100 L,-40-100℃
Research-grade laboratory product
Product Overview

Programmable Touchscreen Constant Temperature and Humidity Chamber, 100 L,-40-100℃ is a programmable touchscreen constant temperature and humidity chamber built for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation. This configuration provides 100 l chamber volume, -40 to 100 C, 35%rh to 95%rh humidity control, imported 304 mirror-finish stainless-steel chamber interior and programmable color touchscreen controller with curve display and multi-language interface for stable day-to-day laboratory operation.

This family combines fluorine-free design, imported 304 stainless-steel inner chamber construction, balancing temperature-humidity control, test-port access and color-touchscreen editing as key chamber elements. The chamber combines balancing-control refrigeration system with multi-point safety protection with high-temperature humidity sensor for real-time monitoring, 2 shelves and an interior size of 500 x 400 x 600 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

This range is intended for laboratories that want staged touchscreen programs, multilingual interface, stored curves, PID self-tuning and safety protection in one humidity-chamber platform. Installation planning can be based on the external size of 700 x 1040 x 1750 mm and the stated power requirement of 7050 W. Optional functions such as embedded printer; rs485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BCB0100
Manufacturer Model BPS-100CB
Capacity 100 L
Temperature Control Range -40 to 100 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity High temperature: +/- 0.5 C; low temperature: +/- 1 C
Humidity Function 35%RH to 95%RH
Humidity Deviation +/- 3%RH
Controller programmable color touchscreen controller with curve display and multi-language interface
Chamber Material imported 304 mirror-finish stainless-steel chamber interior
Power / Input 7050 W
Power Supply AC 380 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration high-temperature humidity sensor for real-time monitoring
Cooling System balancing-control refrigeration system with multi-point safety protection
Internal Dimensions 500 x 400 x 600 mm
External Dimensions 700 x 1040 x 1750 mm
Shelves / Light Decks 2 shelves
Program Function Touchscreen controller supports up to 100 programs, 1000 segments and 999 cycle steps, with a maximum time setting of 99 h 59 min per segment
Optional Accessories and Functions embedded printer; RS485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration
Performance Features
  • Color touchscreen operation helps simplify program editing, parameter review and real-time curve observation during chamber use. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Large program capacity supports staged environmental methods that need repeated cycles and multiple segments. This supports staged test methods and repeatable laboratory workflows that need cycle-based control.
  • PID auto-tuning helps correct temperature and humidity deviations quickly for more stable chamber control. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
  • Balancing-control refrigeration and imported stainless-steel chamber construction support reliable long-duration operation. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Independent alarm and protection functions cover over-temperature, overload, over-current, fan and compressor conditions. This helps maintain dependable low-temperature performance and stable chamber recovery during repeated use.
  • Optional communication, printer and wireless-alarm functions make it easier to store, replay and supervise chamber records. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
APPLICATION SCOPE: Suitable for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 700 x 1040 x 1750 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber requires a dedicated AC 380V 50Hz power supply with proper grounding and over-current protection, and must be operated in a well-ventilated environment with ambient temperature between 5°C and 30°C. Ensure all air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance.

  • Installation Space: Verify the installation location accommodates the external dimensions of 700 x 1040 x 1750 mm with clearances for ventilation and access.
  • Power Supply: Connect the chamber to a dedicated AC 380V 50Hz circuit rated for at least 7050 W with a residual-current device.
  • Ambient Temperature: Operate the chamber only within the specified ambient temperature range of 5°C to 30°C to prevent performance degradation.
  • Upright Transport: Keep the chamber upright at all times during transport and positioning, and use suitable lifting equipment to prevent impact damage.
  • Accessibility: Keep air inlets, test ports, shelving, drain areas, doors, and controller surfaces accessible for routine cleaning and maintenance.

Follow these steps to safely install the chamber and prepare it for operation. Ensure all handling and installation procedures are performed by qualified personnel.

Required Equipment: Suitable lifting equipment (e.g., forklift or pallet jack)

  1. Verify installation space
    Confirm the installation location accommodates the chamber's external dimensions of 700 x 1040 x 1750 mm with clearances for ventilation and access.
  2. Prepare power supply
    Prepare a dedicated AC 380V 50Hz power supply with proper grounding and over-current protection rated for the chamber's 7050 W load.
  3. Transport and position chamber
    Keep the packed chamber upright at all times during transport and use suitable lifting equipment to unload and position the unit.
  4. Ensure accessibility
    After installation, ensure all air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance.
  5. Power on and configure
    Power on the chamber, verify the controller initializes, and program the desired temperature and humidity profile using the touchscreen interface.

How does the temperature uniformity specification differ between the high-temperature and low-temperature operating ranges for the BPS-100CB chamber?

The temperature uniformity specification is ±0.5°C for high-temperature operation and ±1°C for low-temperature operation, as stated in the technical specifications. This difference reflects the performance characteristics of the balancing-control refrigeration system at different setpoints.

What are the power supply requirements for the Atomfair BPS-100CB constant temperature and humidity chamber, and can it be adapted for standard 208-240V laboratory circuits?

The chamber requires a dedicated AC 380V, 50Hz power supply with a power input of 7050W. The product description does not mention adaptation to 208-240V circuits; therefore, a 380V supply must be available at the installation site. For alternative power configurations, contact Atomfair's technical sales team.

What is the recommended working environment temperature range for the BPS-100CB chamber, and why is it critical for operation?

The chamber is designed to operate in a working environment of +5°C to 30°C, as specified in the technical data. Maintaining this ambient range is critical because the balancing-control refrigeration system relies on stable room conditions to achieve accurate temperature and humidity control, prevent condensation, and ensure long-term reliability.

This 100 L chamber provides -40 to 100°C with 35-95% RH, featuring a programmable touchscreen controller with 100-program capacity, PID auto-tuning, and 304 stainless steel interior. Requires 380V/7050W power and operation within 5-30°C ambient.

Positive

  • Large program capacity for complex protocols: Supports up to 100 programs, 1000 segments, and 999 cycle steps, enabling staged environmental methods for repeated cycles and multi-segment test workflows.
  • PID auto-tuning for stable control: PID auto-tuning corrects temperature and humidity deviations quickly, supporting humidity-sensitive incubation, cultivation, and stability-study applications.

Trade-offs

  • High power and voltage requirement: Requires 7050 W at AC 380 V, 50 Hz, which may necessitate dedicated electrical infrastructure and is not compatible with standard 120/240 V lab outlets.
  • Ambient temperature operating constraint: The chamber must be operated in a working environment of +5 to 30°C, limiting placement to temperature-controlled laboratory spaces.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).