240 L Biological Safety Incubator with HEPA Filtration
Research-grade laboratory product
Product Overview

240 L Biological Safety Incubator with HEPA Filtration is designed for biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation. Gas-jacket heating, HEPA filtration, UV sterilization, and touchscreen monitoring for biological safety incubation. The configuration provides RT + 5 to 50 °C, 950 W rated power, a working chamber of 600 × 630 × 670 mm (W × D × H), and external dimensions of 788 × 837 × 940 mm (W × D × H).

The control and chamber design support practical laboratory operation: Touchscreen controller with password lock. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system.

This equipment is suited to laboratories that need biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BSIN-240
Product Family Biological Safety Incubator
Configuration 240 L
Rated Operating Power 950 W
Working Chamber Size 600 × 630 × 670 mm (W × D × H)
Overall Dimensions 788 × 837 × 940 mm (W × D × H)
Heating Method Gas-jacket microcomputer PID control
Temperature Control Range RT + 5 to 50 °C
Working Ambient Temperature +5 to +30 °C
Temperature Stability ±0.1 °C at 37 °C
Temperature Uniformity ±0.5 °C at 37 °C
Sterilization Method UV sterilization
Power Supply AC 220 V, 50 Hz
Controller Touchscreen controller with password lock
Chamber Protection HEPA filter and test port access
Optional Accessories and Functions 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system
Performance Features
  • This product family combines incubation control and biological safety protection with standard HEPA filtration. This helps maintain cleaner chamber air for contamination-sensitive biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation.
  • A touchscreen controller supports direct monitoring and parameter setting, with password locking to reduce unintended changes. This makes real-time parameter review and routine operation easier in biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation.
  • Six-side heating reduces condensation inside the chamber and supports stable culture conditions. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • The chamber and shelves use stainless-steel construction for cleaning and maintenance. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • USB export, electronic signature support, and optional App monitoring support traceable operation. This allows the configuration to match documentation, communication and monitoring needs in biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation.
  • Optional 90 °C high-temperature and high-humidity sterilization is available for inner chamber decontamination. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
APPLICATION SCOPE: Suitable for biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 788 × 837 × 940 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a working ambient temperature of +5 to +30 °C and a power supply of AC 220 V, 50 Hz. HEPA filtration and UV sterilization are standard; optional 90 °C high-temperature and high-humidity sterilization requires workflow-specific selection.

  • Installation Space Requirement: Confirm available space against the 788 × 837 × 940 mm external dimensions before installation.
  • Accessibility Requirement: Keep the chamber, sensors, shelves, filters, doors, test ports, and control interfaces accessible for cleaning, inspection, and operation.
  • Transport Constraint: Keep the packed unit upright during transport and use suitable lifting equipment to reduce movement and impact risk.

Position the incubator in a space meeting the external dimension and ambient temperature requirements. Connect to the specified power supply and verify all chamber access points are unobstructed.

Required Equipment: Suitable lifting equipment, AC 220 V, 50 Hz power supply

  1. Verify Installation Space
    Confirm the installation area accommodates the 788 × 837 × 940 mm external dimensions with clearance for chamber access.
  2. Connect Power Supply
    Connect the incubator to an AC 220 V, 50 Hz power outlet that meets the 950 W rated power requirement.
  3. Set Temperature Parameters
    Use the touchscreen controller to set the desired incubation temperature within the RT + 5 to 50 °C range.
  4. Enable UV Sterilization
    Activate the UV sterilization system via the touchscreen before loading samples to decontaminate the chamber.
  5. Load Samples
    Place culture vessels on the stainless-steel shelves, ensuring airflow is not obstructed by overloading.
  6. Monitor Chamber Conditions
    Verify temperature stability and uniformity using the touchscreen display before starting the incubation cycle.

How does the gas-jacket heating system in the AF-BSIN-240 maintain temperature uniformity and stability for sensitive cultures?

The gas-jacket microcomputer PID control delivers temperature stability of ±0.1 °C at 37 °C and uniformity of ±0.5 °C at 37 °C. Six-side heating reduces internal condensation and supports stable culture conditions, as specified in the technical specifications.

What contamination control measures are integrated into the 240 L Biological Safety Incubator?

Standard HEPA filtration maintains cleaner chamber air for contamination-sensitive work, and UV sterilization is included. An optional 90 °C high-temperature and high-humidity sterilization system is available for decontamination. The stainless-steel chamber and shelves facilitate repeated cleaning.

What are the critical installation requirements for the 240 L Biological Safety Incubator?

The incubator requires an AC 220 V, 50 Hz power supply with 950 W rated power. The external dimensions are 788 × 837 × 940 mm (W × D × H), and the working ambient temperature range is +5 to +30 °C. Ensure chamber access, sensors, filters, and test ports remain accessible for operation and maintenance.

The 240 L Biological Safety Incubator with HEPA Filtration combines gas-jacket PID heating, six-side temperature control, and HEPA/UV sterilization to support contamination-sensitive culture work, though its limited temperature range (RT+5 to 50°C) and ambient dependency (5–30°C) require a controlled laboratory environment.

Positive

  • HEPA and UV sterilization integration: Standard HEPA filtration and UV sterilization provide active contamination control for biological safety incubation and culture work, reducing airborne particulates and microbial load inside the chamber.
  • Gas-jacket heating with six-side uniformity: Six-side gas-jacket microcomputer PID heating delivers ±0.1°C temperature stability and ±0.5°C uniformity at 37°C while minimizing condensation, supporting stable and repeatable culture conditions.

Trade-offs

  • Restricted temperature and ambient range: The incubator operates only from RT+5 to 50°C and requires an ambient temperature of +5 to +30°C, limiting its use to low-to-moderate temperature applications and climate-controlled laboratories.
  • Critical features are optional accessories: High-temperature decontamination (90°C), data logging via USB/RS485, electronic signature, and smart App control are not included; they must be ordered separately, increasing upfront cost and lead time for full capability.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).