220 L Biological Safety Low-Temperature Incubator with HEPA Filtration
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a minimum chamber temperature 20 °C below ambient, limiting placement in unconditioned spaces. HEPA filtration and UV sterilization demand periodic filter replacement and lamp maintenance to sustain contamination control.
- Environmental Installation Constraint: Confirm available space against the 793 × 975 × 853 mm external dimensions and provide a dedicated AC 220 V, 50 Hz power supply before installation.
- Sterilization System Maintenance: The optional 90 °C high-temperature and high-humidity sterilization cycle requires the chamber to be empty and all internal components to be heat-resistant.
- Accessibility Requirement: Keep the chamber, sensors, shelves, filters, doors, test ports, and control interfaces accessible for cleaning, inspection, and operation.
This procedure covers initial setup and verification of the incubator for low-temperature biological safety cultivation. Follow these steps after unpacking and before loading samples.
Required Equipment: 7-inch color touchscreen controller, HEPA filter, UV sterilization system
- Position the Incubator
Place the incubator on a level, stable surface with at least 10 cm clearance on all sides for airflow and access. - Connect Power Supply
Connect the unit to a dedicated AC 220 V, 50 Hz power outlet and verify the power indicator illuminates. - Set Temperature Parameters
Use the touchscreen controller to set the target temperature between 4 and 65 °C, ensuring the set point is at least 20 °C below ambient. - Activate HEPA Filtration
Enable the HEPA filtration system via the controller and allow it to run for 15 minutes to establish clean chamber air. - Perform UV Sterilization Cycle
Activate the UV sterilization system for 30 minutes with the chamber empty and door closed to decontaminate internal surfaces. - Verify Temperature Stability
Monitor the temperature reading on the controller until it stabilizes within ±0.1 °C at the set point before loading samples.
How does the six-side heating design affect temperature uniformity and condensation control in low-temperature biological safety incubators?
The six-side heating design helps reduce condensation inside the chamber and supports a cleaner cultivation environment. At 37 °C, the incubator achieves a temperature uniformity of ±0.5 °C and stability of ±0.1 °C, as stated in the technical specifications. This design minimizes cold spots that could cause condensation, supporting contamination-sensitive workflows.
What are the installation space and power supply requirements for the 220 L Biological Safety Low-Temperature Incubator?
The incubator has external dimensions of 793 × 975 × 853 mm (W × H × D) and requires a power supply of AC 220 V, 50 Hz with a rated operating power of 1800 W. Before installation, confirm available space and ensure the power supply meets these specifications as documented in the product description.
What sterilization methods are available for this incubator, and what are the considerations for choosing between UV and high-temperature high-humidity sterilization?
The standard model includes UV sterilization, while an optional 90 °C high-temperature and high-humidity sterilization system is available. The UV system is built-in, whereas the high-temperature cycle requires selecting the optional accessory. As noted in the optional functions, UV is suitable for routine surface disinfection, while high-temperature sterilization provides more thorough decontamination of the chamber and internal components.
The 220 L Biological Safety Low-Temperature Incubator with HEPA filtration provides controlled low-temperature incubation with ±0.1°C stability, a stainless steel chamber, and six-side heating, but its minimum temperature is limited to 20°C below ambient and key sterilization features are optional.
Positive
- HEPA filtration and six-side heating: The standard HEPA filter removes bacteria and dust from circulating air, and six-side heating reduces condensation, supporting contamination-sensitive low-temperature cultivation.
- Stainless steel chamber with rounded corners: 304 stainless-steel chamber and rounded internal corners facilitate repeated cleaning and maintenance, reducing contamination risk.
Trade-offs
- Temperature limited to 20°C below ambient: The incubator's minimum chamber temperature is 20 °C below ambient, meaning it cannot achieve very low temperatures if ambient is high; requires adequate lab cooling.
- High-temperature sterilization is optional: The 90°C high-temperature and high-humidity sterilization system is optional; the base unit includes only UV sterilization, which may be insufficient for some workflows.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).