Biological Safety Incubator 155 L HEPA 750 W ATOMFAIR®

$3,500.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

155 L biological safety incubator with HEPA filtration, 750 W power, and RT + 5 to 50 °C control for contamination-sensitive culture work. Order now.

SKU: AF-LE-E-BSIN-0155-S155
Category:
Brands:

155 L Biological Safety Incubator with HEPA Filtration
Research-grade laboratory product
Product Overview

155 L Biological Safety Incubator with HEPA Filtration is designed for biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation. Gas-jacket heating, HEPA filtration, UV sterilization, and touchscreen monitoring for biological safety incubation. The configuration provides RT + 5 to 50 °C, 750 W rated power, a working chamber of 480 × 530 × 610 mm (W × D × H), and external dimensions of 670 × 767 × 880 mm (W × D × H).

The control and chamber design support practical laboratory operation: Touchscreen controller with password lock. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system.

This equipment is suited to laboratories that need biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BSIN-155
Product Family Biological Safety Incubator
Configuration 155 L
Rated Operating Power 750 W
Working Chamber Size 480 × 530 × 610 mm (W × D × H)
Overall Dimensions 670 × 767 × 880 mm (W × D × H)
Heating Method Gas-jacket microcomputer PID control
Temperature Control Range RT + 5 to 50 °C
Working Ambient Temperature +5 to +30 °C
Temperature Stability ±0.1 °C at 37 °C
Temperature Uniformity ±0.5 °C at 37 °C
Sterilization Method UV sterilization
Power Supply AC 220 V, 50 Hz
Controller Touchscreen controller with password lock
Chamber Protection HEPA filter and test port access
Optional Accessories and Functions 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system
Performance Features
  • This product family combines incubation control and biological safety protection with standard HEPA filtration. This helps maintain cleaner chamber air for contamination-sensitive biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation.
  • A touchscreen controller supports direct monitoring and parameter setting, with password locking to reduce unintended changes. This makes real-time parameter review and routine operation easier in biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation.
  • Six-side heating reduces condensation inside the chamber and supports stable culture conditions. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • The chamber and shelves use stainless-steel construction for cleaning and maintenance. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • USB export, electronic signature support, and optional App monitoring support traceable operation. This allows the configuration to match documentation, communication and monitoring needs in biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation.
  • Optional 90 °C high-temperature and high-humidity sterilization is available for inner chamber decontamination. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
APPLICATION SCOPE: Suitable for biological safety incubation, contamination-sensitive culture work, and temperature-controlled laboratory cultivation in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 670 × 767 × 880 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a working ambient temperature of +5 to +30 °C and a power supply of AC 220 V, 50 Hz. HEPA filtration and UV sterilization are standard; optional 90 °C high-temperature and high-humidity sterilization is available for decontamination.

  • Temperature Control Constraint: Temperature control range is RT +5 to 50 °C with stability of ±0.1 °C and uniformity of ±0.5 °C at 37 °C.
  • Installation Space Constraint: Confirm available space against external dimensions of 670 × 767 × 880 mm (W × D × H) before installation.
  • Sterilization Method Constraint: UV sterilization is standard; optional 90 °C high-temperature and high-humidity sterilization system is available for inner chamber decontamination.
  • Accessory Selection Constraint: Select optional accessories including independent over-temperature controller, embedded printer, USB data storage, RS485 interface, electronic signature function, or smart App control system according to workflow.

Install the incubator in a space meeting the external dimensions and power supply requirements. Operate using the touchscreen controller with password lock for monitoring and parameter setting.

Required Equipment: Touchscreen controller with password lock, HEPA filter and test port access, UV sterilization system

  1. Verify Installation Space
    Confirm the available space accommodates the 670 × 767 × 880 mm external dimensions and provides AC 220 V, 50 Hz power supply.
  2. Unpack and Position Incubator
    Keep the packed unit upright during transport and use suitable lifting equipment to move it to the installation location.
  3. Connect Power Supply
    Connect the incubator to the specified AC 220 V, 50 Hz power supply and ensure the chamber, sensors, shelves, filters, doors, test ports, and control interfaces are accessible.
  4. Set Temperature Parameters
    Use the touchscreen controller to set the desired temperature within the RT +5 to 50 °C range and enable password lock to prevent unintended changes.
  5. Activate Sterilization Cycle
    Select UV sterilization or optional 90 °C high-temperature and high-humidity sterilization to decontaminate the chamber before use.
  6. Monitor Chamber Conditions
    Monitor temperature stability and uniformity via the touchscreen display, and verify HEPA filtration performance through the test port access.

What is the temperature stability and uniformity of the 155 L Biological Safety Incubator at typical culture conditions?

The incubator maintains temperature stability of ±0.1 °C and uniformity of ±0.5 °C at 37 °C, controlled by gas-jacket microcomputer PID heating. This level of precision supports contamination-sensitive culture work requiring consistent conditions.

How does the HEPA filtration and UV sterilization work together to maintain biological safety in this incubator?

The incubator includes standard HEPA filtration to maintain cleaner chamber air for contamination-sensitive work, plus UV sterilization as the primary sterilization method. An optional 90 °C high-temperature and high-humidity sterilization system can be added for deeper decontamination of the inner chamber. The combination allows users to select the appropriate sterilization for their workflow.

What are the power and space requirements for installing the 155 L Biological Safety Incubator?

The incubator requires a power supply of AC 220 V, 50 Hz, with a rated power of 750 W. The external dimensions are 670 × 767 × 880 mm (W × D × H), and the working ambient temperature must be +5 to +30 °C. Users should confirm available space and power before installation.

The 155 L Biological Safety Incubator integrates HEPA filtration, gas-jacket PID heating, and UV sterilization for contamination-sensitive culture work. Its six-side heating reduces condensation and improves temperature uniformity (±0.5°C at 37°C), while the touchscreen controller with password lock enables secure operation. However, the temperature range is limited to RT+5–50°C, and basic decontamination relies on UV; the 90°C high-temperature sterilization is optional.

Positive

  • HEPA Filtration for Contamination Control: Standard HEPA filtration helps maintain cleaner chamber air, reducing contamination risk during biological safety incubation and culture work.
  • Six-Side Heating Reduces Condensation: Six-side heating minimizes internal condensation and supports stable culture conditions, improving temperature uniformity (±0.5°C at 37°C) for reproducible results.

Trade-offs

  • Limited Temperature Range: Operating range is RT+5 to 50°C, restricting use for applications requiring higher incubation temperatures or heat-based decontamination without the optional 90°C sterilization system.
  • Optional High-Temp Sterilization Required: Basic unit includes UV sterilization only; effective decontamination at 90°C requires purchasing the optional high-temperature and high-humidity sterilization system, increasing cost and complexity.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).