800L Large-Capacity Biochemical Incubator, 0-60°C
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, specification comparison, accessory review, or quotation support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
The incubator requires an ambient temperature range of +5 to 30°C and a power supply of AC220V 50Hz with 2050 W input. Temperature uniformity is ±2.5°C at 25°C, with fluctuation of high temp ±0.5°C and low temp ±1.0°C.
- Ambient Temperature Constraint: Operate the incubator only within an ambient temperature range of +5 to 30°C to maintain specified performance.
- Power Supply Requirement: Connect the incubator to a stable AC220V 50Hz power source capable of supplying at least 2050 W.
- Temperature Uniformity Limitation: Expect a temperature uniformity of ±2.5°C at 25°C, which may affect sample positioning within the chamber.
- Temperature Fluctuation Tolerance: Anticipate temperature fluctuation of high temp ±0.5°C and low temp ±1.0°C during operation.
This procedure covers initial setup, loading, and routine operation of the incubator for biochemical incubation or sample preservation. Follow these steps to ensure stable temperature control and safe handling.
Required Equipment: Liquid-crystal display controller or digital display controller, 3 adjustable shelves
- Verify Installation Environment
Confirm the incubator is placed on a level floor in a room with ambient temperature between +5 and 30°C and adequate ventilation. - Connect Power Supply
Plug the incubator into a dedicated AC220V 50Hz outlet rated for at least 2050 W. - Set Temperature Parameters
Use the controller to set the desired temperature within the 0-60°C range, adjusting in 0.1°C increments. - Load Samples
Place sample vessels on the adjustable shelves, ensuring even distribution to minimize position-related temperature differences. - Monitor Temperature Stability
Allow the chamber to stabilize for at least 30 minutes, then verify the displayed temperature matches the setpoint within fluctuation limits.
How does the temperature fluctuation differ between high and low temperature setpoints in the 800L biochemical incubator?
The incubator specifies a temperature fluctuation of ±0.5°C at high temperatures and ±1.0°C at low temperatures, as stated in the product specifications. This difference reflects the inherent challenge of maintaining tighter stability at elevated setpoints versus near-ambient or lower ranges.
Can the 800L biochemical incubator be connected to external data logging or monitoring systems?
Yes, the incubator offers optional accessories including an embedded printer, RS485 communication interface, and USB data transfer for selected configurations. These options allow integration with external data recording and monitoring systems, though availability should be confirmed by email before ordering.
What are the electrical and environmental installation requirements for the 800L biochemical incubator?
The incubator requires an AC220V 50Hz power supply with an input power of 2050 W (or up to 2800 W depending on configuration). It must be operated in an ambient temperature range of +5 to 30°C. The overall dimensions are 870x1085x2065mm, requiring adequate floor space and clearance for ventilation.
The 800L large-capacity biochemical incubator (AF-LE-E-BINC-0800-VAR) provides a 0-60°C range with 0.1°C resolution and ±2.5°C uniformity at 25°C, suitable for routine incubation and BOD holding, though low-temperature fluctuation of ±1.0°C and a 2050-2800W power draw impose infrastructure constraints.
Positive
- Large 800L capacity: The 730x750x1480mm chamber supports high-volume sample staging and multi-vessel loading, reducing batch-to-batch handling for routine biochemical incubation and BOD analysis.
- Fine 0.1°C temperature resolution: The 0.1°C setpoint resolution combined with high-temp ±0.5°C fluctuation enables tighter control for cultivation and preservation methods requiring thermal repeatability.
Trade-offs
- Low-temp fluctuation limit: At low operating temperatures, temperature fluctuation increases to ±1.0°C, which may constrain applications requiring sub-ambient stability within tighter tolerances.
- High input power requirement: The 2050-2800W input power at AC220V 50Hz demands dedicated circuit capacity, potentially limiting placement in labs with shared or undersized electrical infrastructure.