600L General Biochemical Incubator with 5-70°C Temperature Control Range
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, capacity matching, power supply confirmation or configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
The incubator requires ambient temperature below 26°C when the set temperature is below 10°C. This constraint ensures stable temperature control and prevents performance degradation.
- Ambient Temperature Constraint: When the set temperature is below 10°C, the ambient temperature must be below 26°C to maintain proper operation.
What is the temperature uniformity specification for the 600L biochemical incubator and how does it affect incubation consistency?
The temperature uniformity is ±2°C across the working chamber. The incubator uses a circulation fan and air-duct structure to improve chamber temperature uniformity, which helps maintain more consistent incubation conditions across the usable 675 x 800 x 1100 mm space.
What ambient temperature conditions are required when operating the incubator at set points below 10°C?
When the set temperature is below 10°C, the ambient temperature must be below 26°C. This constraint is critical for maintaining stable low-temperature operation and preventing excessive heat load on the cooling system.
What are the power supply requirements and rated power consumption for this 600L incubator?
The incubator requires AC 220 V, 50 Hz power supply with a rated power of 1200 W. This power specification supports the microcomputer control, PID temperature regulation, LCD display, and circulation fan for consistent 5–70°C operation.
The 600L General Biochemical Incubator (AF-BI600-T70) offers a 5–70 °C control range with ±1 °C accuracy and ±2 °C uniformity, supported by PID control and an air-duct circulation system, making it suitable for microbiology culture, BOD analysis, and temperature-sensitive sample holding, though it requires ambient temperatures below 26 °C when set below 10 °C.
Positive
- Wide temperature range with stability: The 5–70 °C control range with PID regulation and air-duct circulation supports low-temperature storage, constant-temperature incubation, and BOD work, with ±1 °C accuracy and ±2 °C uniformity for repeatable culture conditions.
- Stainless-steel chamber for durability: The stainless-steel working chamber and removable shelves facilitate cleaning, corrosion resistance, and flexible internal layout adjustment for bottles, flasks, and culture containers in routine laboratory use.
Trade-offs
- Ambient temperature constraint at low setpoints: When the set temperature is below 10 °C, the ambient temperature must be below 26 °C, which imposes an infrastructure requirement on lab cooling capacity for low-temperature applications.
- Single voltage standard limits flexibility: The unit operates on AC 220 V, 50 Hz power only, requiring compatibility verification for labs with 110 V or 60 Hz supplies unless a transformer or frequency converter is used.