350L General Biochemical Incubator with 0-50°C Temperature Control Range
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, capacity matching, power supply confirmation or configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
This document defines the installation and operating limits for the ATOMFAIR 350 L general biochemical incubator. Safe and consistent operation depends on respecting the ambient temperature restriction and the electrical supply requirements.
- Low-set-point ambient limit: Maintain the surrounding room temperature below 26°C whenever the incubator set temperature is below 10°C.
- Electrical service verification: Confirm that the incoming supply is AC 220 V, 50 Hz and has sufficient capacity for the rated 800 W load before connecting the unit.
- Placement clearance: Verify that the installation space can accept the cabinet footprint and allows access for service and observation.
- Door operation: Use the inner observation door to check the chamber and avoid repeated full-door openings during temperature-holding cycles.
- Chamber loading discipline: Arrange culture vessels on removable shelves so that internal air circulation and temperature uniformity are not obstructed.
These steps describe the safe initialization and routine handling of the ATOMFAIR 350 L biochemical incubator. The sequence covers power and ambient checks, temperature setup, sample loading, and door discipline.
- Confirm utilities
Confirm that the power supply is AC 220 V, 50 Hz and that the selected installation location has adequate clearance for the cabinet. - Check ambient temperature
Verify that the ambient temperature is below 26°C before setting an incubator temperature below 10°C. - Set temperature and timer
Set the required temperature and timing range on the microcomputer controller using the LCD display. - Load samples
Arrange culture flasks, bottles, or sample vessels on the removable shelves with spacing for even air circulation. - Monitor chamber
Use the inner observation door to inspect chamber conditions and keep the outer magnetic door closed during operation.
What is the temperature uniformity specification for the 350L biochemical incubator and how does it affect incubation consistency?
The temperature uniformity is ±2°C across the usable chamber space. This is supported by a circulation fan and air-duct structure that help improve chamber temperature uniformity, which is beneficial for more consistent incubation conditions across the usable space.
What ambient temperature conditions are required when operating the incubator below 10°C?
When the set temperature is below 10°C, the ambient temperature must be below 26°C. This is a critical operational constraint to ensure the incubator can maintain low set points reliably; failure to meet this condition may affect temperature control performance.
How does the magnetic door seal and inner door design improve operational efficiency and reduce temperature disturbance?
The magnetic door sealing structure improves closing convenience and chamber tightness, helping reduce unnecessary disturbance during operation. The inner door structure and visual observation design allow users to check chamber conditions more conveniently while reducing frequent full-door opening, which minimizes temperature fluctuations.
This 350L biochemical incubator provides a 0-50°C control range with PID temperature management and LCD monitoring, suited for microbiology culture and BOD work. The stainless-steel chamber and magnetic door seal support cleanliness and thermal stability, though operation below 10°C requires ambient temperatures under 26°C, imposing a facility constraint.
Positive
- Stainless-steel chamber with magnetic seal: The 304-type stainless-steel working chamber combined with a magnetic door seal enhances corrosion resistance, cleanliness, and chamber tightness, reducing thermal disturbance during incubation.
- PID control with LCD monitoring: Microcomputer PID control minimizes temperature fluctuation, while the LCD display provides real-time set-point and current temperature visibility, improving operational consistency for culture storage and incubation.
Trade-offs
- Ambient temperature constraint below 10°C: When operating below 10°C set-point, ambient temperature must be ≤26°C, requiring air-conditioned lab space to avoid inadequate cooling performance or control drift.
- Limited shelf count at standard configuration: The unit ships with only 2 adjustable shelves, which may require additional purchases for high-throughput applications using multiple culture containers or BOD bottles.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).