Temperature and Humidity Chamber 150 L 5–50°C ATOMFAIR®

$1,600.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 150 L temperature and humidity chamber with 5–50°C control, 50–90%RH range, 304 stainless chamber and 600 W input for routine culture. Order now.

SKU: AF-LE-E-HSPB-0150-15BE
Category:
Brands:

Temperature and Humidity Chamber, 150 L
Research-grade laboratory product
Product Overview

Temperature and Humidity Chamber, 150 L is a practical chamber for environmental protection, epidemic prevention, veterinary research, drug testing, aquatic research, BOD measurement, microbial culture, plant cultivation and breeding tests. It brings together 150 l of usable space, 5 to 50 C, 50%rh to 90%rh humidity control, so the chamber can keep samples in a steady, repeatable working condition.

The inner door uses tempered glass, the outer door uses a magnetic sealing strip, and the ducted air system helps improve chamber uniformity and observation convenience. The cabinet uses a stainless-steel chamber with rounded corners, removable shelves, a magnetic door seal and hot-cold air ducts, with an internal working room of 395 x 500 x 750 mm and an external footprint of 652 x 655 x 1420 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The series combines temperature and humidity control with memory and self-diagnosis functions so that the chamber can keep operating reliably after power interruptions or alarms. The stated input power is 600 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-HSP150BE
Capacity 150 L
Temperature Control Range 5 to 50 C
Temperature Resolution 0.1 C
Temperature Fluctuation +/- 1 C
Humidity Range 50%RH to 90%RH
Humidity Deviation < 8%RH
Controller LCD screen with programmable temperature, humidity and time control
Chamber Material 304 stainless-steel working chamber
Exterior Shell Powder-coated steel shell
Power / Input 600 W
Power Supply AC 220 V, 50 Hz
Timer Range 0 to 9999 min
Internal Dimensions 395 x 500 x 750 mm
External Dimensions 652 x 655 x 1420 mm
Net Weight 82.5 Kg
Shelves / Trays 2 shelves
Configuration Note Note: when set temperature is 10 C or below, ambient temperature should not exceed 26 C; when the set temperature is above 40 C, humidity setpoints should generally not exceed 80%
Performance Features
  • Self-diagnosis and over-temperature self-limiting help protect samples and reduce running risk. This supports more reliable day-to-day chamber use.
  • Power-off memory preserves settings after interruptions and supports continuous workflows. This helps preserve operation settings after power interruptions.
  • The embedded screen and multi-parameter display make operation and status review straightforward. This supports more reliable day-to-day chamber use.
  • The magnetic outer door seal and tempered-glass inner door improve sealing and observation. This improves observation and helps reduce heat loss while checking samples.
  • Hot and cold air ducts help improve chamber circulation and temperature uniformity. This helps improve chamber circulation and temperature uniformity.
  • Programmable temperature, humidity and time control suits repeatable laboratory methods. This is useful for cultivation, conditioning and biological workflows that need moisture control.
APPLICATION SCOPE: Suitable for environmental protection, epidemic prevention, veterinary research, drug testing, aquatic research, BOD measurement, microbial culture, plant cultivation and breeding tests in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber upright, maintain clear air paths and allow sufficient service space around the unit for ventilation and maintenance. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When the set temperature is 10 C or below, ambient temperature should not exceed 26 C. When the set temperature is above 40 C, the humidity setpoint is normally kept below 80% to protect service life. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber ambient temperature must not exceed 26°C when the set temperature is 10°C or below. The humidity setpoint should not exceed 80% when the set temperature is above 40°C to protect service life.

  • Ambient temperature limit at low setpoints: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C.
  • Humidity limit at high setpoints: When the set temperature is above 40°C, the humidity setpoint should generally not exceed 80%.
  • Power supply requirement: The chamber requires a grounded AC 220V 50Hz power supply with a 600W input capacity.
  • Ventilation and spacing requirement: Maintain clear air paths and allow sufficient service space around the unit for ventilation and maintenance.
  • Upright handling requirement: Keep the chamber upright during unloading, positioning, and transport to prevent damage.

Position the chamber in a well-ventilated area with adequate clearance and connect to a grounded power supply. Set the desired temperature and humidity parameters via the LCD controller and allow the chamber to stabilize before loading samples.

  1. Position the chamber
    Position the chamber on a level surface with clear air paths and sufficient service space around the unit.
  2. Connect to power
    Connect the power cord to a grounded AC 220V 50Hz outlet.
  3. Set parameters
    Set the desired temperature and humidity parameters via the LCD controller.
  4. Check ambient temperature for low setpoints
    If the set temperature is 10°C or below, verify that the ambient temperature does not exceed 26°C.
  5. Adjust humidity for high setpoints
    If the set temperature is above 40°C, ensure the humidity setpoint is kept below 80%.
  6. Confirm power-off recovery
    After power interruptions, confirm the chamber resumes operation with the stored settings.

What are the operational limits for temperature and humidity setpoints in the Atomfair AF-HSP150BE 150 L chamber?

The chamber operates within a temperature range of 5 to 50 °C and humidity range of 50% to 90% RH. However, when the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C. When the set temperature is above 40 °C, humidity setpoints should generally not exceed 80% to protect service life. Additionally, temperature fluctuation is ±1 °C and humidity deviation is less than 8% RH.

What ambient temperature conditions are required for the AF-HSP150BE chamber to operate at low temperature setpoints?

For reliable low-temperature operation, when the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C. The chamber is powered by AC 220 V, 50 Hz and draws 600 W. The internal dimensions are 395 x 500 x 750 mm, and the unit weighs 82.5 kg, requiring adequate floor space and service clearance.

How does the power-off memory and self-diagnosis feature protect samples in the Atomfair AF-HSP150BE chamber?

The power-off memory preserves all temperature, humidity, and timer settings after an interruption, allowing continuous workflows without manual reprogramming. The self-diagnosis and over-temperature self-limiting functions reduce operational risk by automatically detecting and responding to abnormal conditions. The magnetic outer door seal and tempered-glass inner door further improve sealing and observation, minimizing heat loss during sample checks.

The Atomfair AF-HSP150BE 150 L temperature and humidity chamber provides programmable control with self-diagnosis and power-off memory, supporting reproducible biological and environmental testing. Operational constraints include reduced humidity capability above 40°C and ambient temperature limits when operating below 10°C.

Positive

  • Self-diagnosis and over-temperature protection: Built-in self-diagnosis and over-temperature self-limiting reduce risk to samples and support reliable unattended operation.
  • Power-off memory for workflow continuity: Power-off memory preserves temperature, humidity, and time settings after interruptions, enabling continuous experimental protocols without reprogramming.

Trade-offs

  • Humidity limited at high temperatures: When set temperature exceeds 40°C, humidity setpoints should generally not exceed 80% RH to protect chamber service life.
  • Ambient temperature constraint at low setpoints: When set temperature is 10°C or below, ambient room temperature must not exceed 26°C to maintain stable operation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).