Description
ATOMFAIR® PRECISION ELECTRONIC SCALE SERIES (XY-1B / XY-1BF / XY-2C)RESEARCH GRADE MATERIAL
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official quotations.
EMAIL: inquiry@atomfair.com
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This electronic scale requires a stable, level, and draft-free environment for accurate measurement. Regular calibration with traceable weights is recommended to maintain precision.
- Surface Requirement: Position the scale on a flat, vibration-free workbench to ensure consistent readings.
- Environmental Conditions: Avoid operating the scale near open windows, fans, or temperature extremes to prevent measurement drift.
- Overload Protection: Do not place items exceeding the rated capacity on the pan to avoid sensor damage.
- Calibration: Calibrate the scale with the provided weights before each precision weighing session.
Follow these steps to safely and accurately weigh samples with the electronic scale. This procedure ensures the scale is properly set up and calibrated for reliable results.
Required Equipment:
- Prepare the Work Area
Place the scale on a level, stable surface and ensure it is not exposed to vibrations or drafts. - Power On
Connect the scale to a power source and turn it on using the power button. - Wait for Stabilization
Wait for the display to show zero to indicate the scale is ready for use. - Calibrate if Needed
Calibrate the scale using the provided calibration weight if required for accuracy. - Weigh the Sample
Gently place the sample on the center of the pan and record the displayed weight after it stabilizes. - Power Down
Turn off the scale and disconnect from power when not in use to conserve battery or energy.
What are the performance trade-offs between the XY-1B/1BF and XY-2C models of the Atomfair Precision Electronic Scale?
The XY-2C models include a draft shield to improve reading stability in air currents and come with calibration weights for in-situ accuracy verification, while XY-1B/1BF models lack these features. However, XY-1B/1BF models offer larger capacity options including 6100g and 10kg with 1g readability, which the XY-2C series does not. Therefore, the choice involves a trade-off between enhanced precision at lower capacities versus higher maximum load without draft protection.
Is the Atomfair Precision Electronic Scale suitable for applications requiring 0.01g readability?
No, the Atomfair Precision Electronic Scale's highest readability is 0.1g as shown in the specifications table for all models in both XY-1B/1BF and XY-2C series. It is not designed for milligram-level or 0.01g precision. For such applications, an analytical balance with at least 0.1 mg readability would be required.
How should the Atomfair Precision Electronic Scale be calibrated, and what weights are provided?
Calibration depends on the model. XY-2C models with capacities up to 1100g include calibration weights: 100g for the 110g capacity, 200g for capacities 210g through 610g, and 500g for the 1100g capacity. These weights allow the user to perform a two-point calibration. XY-1B/1BF models and XY-2C models above 1100g do not include weights and require external calibration masses.
This precision scale line provides capacities from 310g to 10kg with readability ranging from 0.1g to 1g, making it suitable for routine lab weighing where high precision is not critical, though users should note the lack of draft shields on entry-level models and the reduced accuracy at higher loads.
Positive
- Wide capacity and pan options: With capacities from 310g to 10kg and pan sizes of Φ13cm round or 16x16cm square, this scale adapts to diverse sample volumes and container shapes in laboratory settings.
- LED High-Definition Display: The LED display ensures clear readability of weight measurements, reducing visual fatigue during repeated weighing tasks.
Trade-offs
- No draft shield on basic models: The XY-1B/1BF series lacks a draft shield, making measurements susceptible to air currents and temperature fluctuations, which can compromise accuracy in precision work.
- Reduced readability at higher capacities: For capacities above 3100g, readability decreases to 1g, limiting the scale's utility for applications requiring fine mass discrimination.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).


