Precision Electronic Analytical Balance 210g/1mg ATOMFAIR®

$299.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

General-purpose analytical balance with 210g capacity and 1mg readability. External calibration with 200g weight included. Stainless steel pan, draft shield, ≤3 sec stabilization. Order now.

SKU: AFMSDEAW445
Category:
Tags:
Brands:

Description

ATOMFAIR PRECISION ELECTRONIC ANALYTICAL BALANCE (210G / 0.001G)

GENERAL-PURPOSE METROLOGY HARDWARE

Product Overview

This premium-grade Analytical Balance balances an extended mid-range capacity threshold with exceptional accuracy, utilizing a calibrated 210g capacity 0.001g readability sensor layout. Developed to function as a general purpose high precision scale standard, this rapid-response configuration generates stable weighing readouts in 3 seconds or less. It features an integrated draft shield analytical weighing glass enclosure that completely isolates mid-range sample matrices from stray ambient ventilation currents. Engineered with an anti-corrosive stainless steel pan and supporting quick external routine calibration, it delivers dependable batch consistency across standard inspection parameters. It represents an essential infrastructure instrument for food production, pharmaceutical evaluation lines, and industrial quality checking applications.

Technical Specifications

SPECIFICATION ITEM TECHNICAL PARAMETER DETAILS
Equipment Model 210g General Purpose Analytical Series
Weighing Capacity Limit 210 g Maximum Operational Range
Readability Resolution 0.001 g (1 mg Fine Resolution Precision)
Minimum Weighing Limit 0.001 g – 0.004 g Minimum Loading Threshold
Stabilization Readout Time ≤3 Seconds High-Speed Measurement Logic
System Calibration Type External Calibration Routine (200g Weight Standard Included)
Weighing Pan Dimensions Φ90 mm Polished Stainless Steel Platform Face
Repeatability Tolerance ±0.002 g Standard Statistical Deviation
Linearity Margin Error ±0.003 g Full Range Accuracy Envelope
Draft Shield Workspace Size 175 mm × 180 mm × 205 mm Multi-Sided Enclosure
Gross Packaging Mass 4 kg Total Transport Bulk Weight
Alternative Upgrade Ports Explore our complete metrology catalog for higher micro-analytical scales, automated motorized internal weights, or peripheral dual screens, serial printing mechanisms, and high-purity dust shielding covers.

Key Features & Advantages

  • Expanded 210g Capacity Core: Engineered to provide exceptional 1mg resolution over an expanded range, allowing researchers to evaluate heavier weighing boats or complex test fixtures easily.
  • Rapid ≤3 Second Micro-Stabilization: Utilizes advanced core balancing circuit algorithms to lock in measurements below 3 seconds, accelerating intense high-throughput material processing.
  • Pre-Installed Anti-Static Draft Shield: Outfitted with a sliding 3-panel glass enclosure matrix designed to safely block convection current fluctuations and local thermal draughts.
  • Durable Stainless Steel Piston Pan: Features an anti-corrosive Φ90mm round platform designed to hold volumetric flasks, watch glasses, or larger composite powder samples safely.

APPLICATION SCOPE: Optimized for mid-capacity pharmaceutical recipe batching, food composite evaluation, chemical analysis operations, and corporate industrial testing frameworks requiring rigorous high-repeatability checking.
SHIPPING & LOGISTICS: Securely encased inside shock-damping multi-layer transit packaging to guarantee flawless delivery. Every shipment arrives complete with a standard 200g calibration weight mass, clear technical guidelines, and electrical adapters.
OPERATIONAL COMPLIANCE NOTICE: Treat this electronic metrology hardware with extreme delicate care; avoid dropping raw materials onto the sensor pan face. Execute an external balance validation pass using the provided 200g weight mass upon initial configuration or changing lab locations. For maximum precision, operate exclusively on a dedicated rigid balance table far from volatile airflow or structural vibrations.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or customized equipment quotations.
EMAIL: INQUIRY@ATOMFAIR.COM
Manufacturer: Atomfair LLC
Brand: ATOMFAIR

This analytical balance requires placement on a vibration-free surface away from air currents to maintain measurement stability. The instrument must undergo external calibration using the included 200 g weight standard to ensure accurate readouts.

  • Air Current Sensitivity: The integrated draft shield must be closed during weighing to isolate samples from ambient ventilation currents.
  • Calibration Requirement: External calibration using the provided 200 g weight is required for accurate measurements.

Place the balance on a stable surface and ensure the draft shield is closed before each measurement. Calibrate the balance externally with the 200 g weight prior to use and allow the reading to stabilize for up to 3 seconds.

Required Equipment: Precision analytical balance with integrated draft shield, 200 g external calibration weight

  1. Place Balance
    Place the analytical balance on a vibration-free and level surface away from drafts and air currents.
  2. Calibrate Balance
    Perform external calibration using the included 200 g weight standard to ensure measurement accuracy.
  3. Weigh Sample
    Place the sample on the stainless steel pan and close the draft shield door before reading the stabilized weight.

How does the 210g capacity with 1mg readability affect the balance's suitability for sub-milligram accuracy applications?

The balance provides 1mg readability (0.001g) with a repeatability of ±0.002g and linearity of ±0.003g, meaning it cannot reliably measure below 1mg. For sub-milligram accuracy, a micro-analytical balance with higher resolution is required.

What are the dimensional constraints for samples when using the integrated draft shield?

The draft shield workspace measures 175mm x 180mm x 205mm, limiting sample height and footprint. Additionally, the stainless steel pan has a 90mm diameter, so samples must be smaller than this to avoid contact with the enclosure walls.

What calibration mass is required to maintain the balance's specified accuracy?

The balance uses external calibration with a 200g weight standard, which is included with the instrument. Routine calibration is necessary to maintain the ±0.002g repeatability and ±0.003g linearity specifications.

This 210g/0.001g analytical balance offers a practical mid-range capacity with 1 mg readability and rapid ≤3 second stabilization, making it suitable for general-purpose metrology in food, pharmaceutical, and industrial quality control labs. Its integrated draft shield and stainless steel pan support routine weighing tasks, though the external calibration requirement and sensitivity to environmental conditions are key operational considerations.

Positive

  • Rapid stabilization for high throughput: The balance achieves stable readouts in ≤3 seconds, enabling efficient processing of multiple samples in high-volume workflows such as pharmaceutical evaluation lines or industrial quality checking.
  • Integrated draft shield for accuracy: The multi-sided glass enclosure isolates samples from ambient air currents and thermal draughts, reducing measurement variability and supporting reliable 1 mg resolution in standard lab environments.

Trade-offs

  • External calibration required: The balance relies on an external calibration routine using the included 200 g weight standard, requiring manual intervention and periodic verification to maintain specified accuracy, unlike models with internal motorized calibration.
  • Sensitive to environmental conditions: While the draft shield mitigates air currents, the balance's 1 mg resolution and ±0.002 g repeatability remain vulnerable to vibrations, temperature gradients, and humidity fluctuations, necessitating a stable, controlled lab bench for optimal performance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).