High-Intensity Programmable Artificial Climate Chamber, 1000 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This chamber requires a dedicated AC 220 V, 50 Hz power supply and must be installed in a +5 to 30°C environment. The unit must be transported upright, and all air inlets, exhaust paths, and control interfaces must remain accessible for safe operation.
- Upright Transport: Transport the chamber in an upright position and use suitable lifting equipment to prevent damage.
- Installation Space: Ensure the installation area accommodates external dimensions of 1410 x 890 x 1950 mm with adequate clearance for ventilation.
- Power Supply: Connect the chamber to a stable AC 220 V, 50 Hz power outlet that meets the 2900 W power requirement.
- Environmental Limits: Operate the chamber only within the specified temperature range of 0 to 50°C (without lighting) or 10 to 50°C (with lighting) and humidity range of 50% to 90% RH.
- Accessibility: Keep air inlets, exhaust paths, shelves, ports, doors, and control interfaces free from obstructions for maintenance and safety.
Prepare the installation site and power supply before unpacking the chamber. After positioning, program the controller for temperature, light, humidity, and time steps to run the desired environmental cycle.
Required Equipment: Suitable lifting equipment
- Confirm Installation Space and Power Supply
Verify that the installation area measures at least 1410 x 890 x 1950 mm and provides a dedicated AC 220 V, 50 Hz power outlet. - Unpack and Position the Chamber
Use suitable lifting equipment to move the packed chamber upright to the installation site, then carefully unpack it. - Ensure Ventilation and Access
Check that all air inlets, exhaust paths, and control interfaces are unobstructed and accessible. - Connect Power and Initialize
Connect the chamber to the power supply and turn on the main power switch to initialize the controller. - Program Environmental Parameters
Use the programmable controller to set temperature, humidity, light intensity, and time steps across up to 30 segments as required. - Verify Operation
Monitor the chamber display and confirm that temperature, humidity, and lighting stabilize within the set points before introducing samples. - Inspect During Extended Runs
Periodically check that the dual compressors alternate automatically and that no alarms or over-limit conditions are displayed.
What is the temperature range difference when operating with high-intensity lighting versus without lighting in the Atomfair AF-MPH1000 climate chamber?
The temperature control range depends on lighting mode: with lighting active, the chamber operates from 10 to 50 °C; without lighting, the range extends to 0 to 50 °C. This specification is per the technical data, with a temperature fluctuation/uniformity of ±1 °C in both modes.
How does the dual compressor system with automatic alternating operation support long-duration continuous cultivation cycles in the AF-MPH1000?
The chamber uses dual imported compressors with automatic alternating operation, which distributes runtime evenly between units to reduce wear and maintain stable refrigeration during extended programs. This design supports dependable low-temperature performance and long-duration running stability for continuous cultivation or climate simulation.
What are the critical installation space and power supply requirements for the Atomfair AF-MPH1000 climate chamber?
The chamber requires an installation space that accommodates external dimensions of 1410 × 890 × 1950 mm, a dedicated AC 220 V, 50 Hz power supply rated at 2900 W, and an ambient working environment of +5 to 30 °C. Proper clearance for air inlets, exhaust paths, and service access must be maintained.
The High-Intensity Programmable Artificial Climate Chamber (1000 L, model AF-MPH1000) delivers up to 35000 lx six-step adjustable lighting, dual alternating compressors, and a 30-segment programmable controller for temperature, humidity, and light, making it well-suited for plant growth and climate simulation. However, its ±1°C temperature uniformity and ±5-7% RH humidity deviation, along with 2900 W power consumption and a 1410 x 890 x 1950 mm footprint, impose specific infrastructure and precision constraints that must be evaluated before deployment.
Positive
- High-Intensity Six-Step Adjustable Lighting: Delivers up to 35000 lx illumination with six-step adjustability and optional partition lighting, supporting demanding plant-growth protocols requiring uniform light distribution across vertical layers.
- Dual Compressor Automatic Alternation: Uses dual imported compressors with automatic alternating operation for prolonged refrigeration stability during extended cultivation cycles, reducing wear and maintaining temperature consistency.
Trade-offs
- Moderate Temperature and Humidity Uniformity: Temperature fluctuation and uniformity specified at ±1°C with humidity deviation of ±5% to 7% RH, which may limit use in applications requiring tighter environmental tolerances.
- High Power and Space Requirements: Requires 2900 W power supply and external dimensions of 1410 x 890 x 1950 mm, necessitating dedicated lab infrastructure and careful installation planning.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).