1435L-6 Anti-Static Mid-Humidity (20%-60% RH) Dry CabinetsDry storage cabinet, mid-humidity control
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
CONTROLLED DRY STORAGE SOLUTIONS
For volume selection, humidity grade confirmation or optional configuration, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The cabinet must be transported upright and placed on a level surface to maintain structural integrity and door seal performance. Extended ambient exposure during door opening must be minimized to prevent moisture ingress and ensure stable humidity control.
- Transport Orientation: Transport the cabinet upright with reinforced outer protection to prevent structural damage to the cabinet body and dehumidification module.
- Level Placement: Place the cabinet on a level surface to ensure proper door sealing and reliable operation of the electronic dehumidification system.
- Door Seal Integrity: Inspect the magnetic sealing gasket periodically to maintain airtight closure and prevent humidity leakage during operation.
- Power Supply Stability: Connect the cabinet to a stable power source to support automatic dehumidification and retain set-point memory after power interruption.
- Ambient Exposure: Minimize the duration of door openings to reduce moisture ingress and maintain the cabinet's relative humidity within the set range.
Position the cabinet on a level surface and connect to stable power before setting the desired humidity set-point. Store moisture-sensitive materials inside after the internal humidity stabilizes, and keep the door closed during normal operation.
Required Equipment: Lifting equipment (forklift or pallet jack), Spirit level
- Transport Cabinet
Transport the cabinet upright to its installation location using appropriate lifting equipment to avoid damage. - Level the Cabinet
Place the cabinet on a level floor and adjust the feet if necessary to ensure stable placement and proper door sealing. - Connect Power
Connect the cabinet to a stable power source and verify that the LCD display illuminates and shows current readings. - Set Humidity Set-Point
Set the desired relative humidity set-point via the microcomputer control interface using the LCD display feedback. - Stabilize Humidity
Allow the internal humidity to reach the set point before introducing stored materials to maintain stable conditions. - Load Materials
Place moisture-sensitive materials onto adjustable shelves, ensuring adequate spacing for air circulation and uniform dehumidification. - Close and Monitor
Close the door securely and monitor the LCD display periodically to confirm humidity and temperature remain within target ranges.
When should I select a mid-humidity (20%-60% RH) dry cabinet instead of a low-humidity or ultra-low-humidity model for moisture-sensitive materials?
The mid-humidity range (20%-60% RH) is intended for materials that need controlled moisture protection without an ultra-dry environment. According to the product overview, it prevents moisture absorption, oxidation, micro-structural degradation, optical haze, and solderability loss. The source states that selectable humidity grades (A, B, C, D) allow matching to actual sensitivity, and this model is suited for research labs, electronics workshops, and optical part storage where balanced humidity is sufficient.
Can the Atomfair AF-DC1435AF-6 dry cabinet be integrated with a nitrogen purge system and remote monitoring for inert atmosphere storage?
Yes, the cabinet supports optional accessories including a nitrogen purge system for fast-purge gas valve configuration and accelerated dehumidification, as well as an RS485 PC logging interface for real-time data logging and remote monitoring. These options are available from the supplier and must be specified before ordering. The microcomputer control retains set parameters after power loss and can trigger an over-humidity alarm if configured.
What are the site preparation and handling requirements for installing the 1435L-6 anti-static dry cabinet?
The cabinet must be transported with reinforced outer protection, kept upright, and moved with suitable lifting equipment due to its volume. After installation, confirm level placement, door sealing, shelf loading, and stable power. The cabinet has a 1.2mm galvanized steel body, 5mm tempered glass door, and magnetic sealing gasket. It is important to keep the door closed during normal use and minimize extended ambient exposure of sensitive materials.
Atomfair AF-DC1435AF-6 provides mid-humidity (20%-60% RH) dry storage with an anti-static powder-coated steel cabinet, Honeywell ±3% RH sensor, and automatic electronic dehumidification, making it suitable for controlled moisture protection in research labs, electronics staging, and optical part storage without the need for ultra-dry conditions.
Positive
- Maintenance-free electronic dehumidification: Automatic dehumidification module eliminates disposable desiccant consumables, supporting continuous operation with minimal maintenance.
- High-precision Honeywell humidity sensing: Honeywell temperature and humidity sensor provides ±3% RH accuracy and 0.3% annual drift for reliable long-term measurement and control.
Trade-offs
- Limited to mid-humidity range: Cabinet controls humidity only within 20%-60% RH, making it unsuitable for materials requiring ultra-low or extreme-low humidity without the optional nitrogen purge system.
- Handling and installation constraints: Due to its 1435L volume and weight, the cabinet requires reinforced packaging, upright transport, and careful level placement to ensure proper sealing and stable operation.