Anti-Oxidation Nitrogen Cabinet 450L ESD Body ATOMFAIR®

$1,550.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

450 L anti-oxidation nitrogen cabinet with anti-static body, 1%-60% RH control, 900 × 600 × 1010 mm size, Honeywell sensing and 0-50 L/min N2 flow. Order now.

SKU: AF-EI-E-AONC-ESD0-450L
Category:
Tags:
Brands:

450L Anti-Oxidation Nitrogen Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 450 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 900 × 600 × 1010 mm, inner dimensions of 855 × 570 × 840 mm and 3 adjustable shelves.

This anti-oxidation nitrogen cabinet is designed for oxidation-sensitive and moisture-sensitive materials that benefit from a controlled low-humidity nitrogen atmosphere. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability during inspection staging, daily handling and long-term preservation.

Typical application areas include research laboratories, electronics workshops, optical part storage rooms, powder and film storage areas, technical archives and quality-control spaces that require organized nitrogen-assisted dry storage. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, Honeywell temperature and humidity sensing, fully automatic computer control, temperature and humidity display, perforated adjustable shelves and 0-50 L/min nitrogen-flow adjustment for repeatable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-AONC450F
Product Family Anti-Oxidation Nitrogen Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 450 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 900 × 600 × 1010 mm
Inner Dimensions (W × D × H) 855 × 570 × 840 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Fully automatic computer control
Display and Monitoring Display-based monitoring for temperature, humidity and operating status
Temperature Display Range -9°C to 99°C
Humidity Display Range 0%-99% RH
Humidity Indication Accuracy ±3% RH
Annual Sensor Drift 0.3%
Sensor Honeywell temperature and humidity sensor
Nitrogen Flow Control 0-50 L/min
Alarm Function Over-humidity alarm support
Suitable Stored Materials Oxidation-sensitive electronic components, optical parts, powders, films and laboratory materials

Key Features and Advantages

  • 1.2 mm galvanized steel cabinet construction with 5 mm tempered-glass viewing panels, magnetic door sealing and a lockable cabinet structure.
  • Honeywell temperature and humidity sensor with ±3% RH humidity indication accuracy and 0.3% annual drift.
  • Fully automatic computer control with temperature display range of -9°C to 99°C and humidity display range of 0%-99% RH.
  • Perforated adjustable shelves support orderly material staging and internal circulation.
  • Nitrogen-control arrangement with 0-50 L/min flow adjustment for controlled cabinet-atmosphere management.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, optical storage rooms, powder and film storage areas, technical archives and quality-control environments that require controlled nitrogen-assisted dry storage for oxidation-sensitive and moisture-sensitive materials.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet maintains a controlled low-humidity nitrogen atmosphere between 1% and 60% RH using a Honeywell sensor with ±3% RH accuracy and 0.3% annual drift. Stable gas supply and even distribution of stored items are required to prevent oxidation and moisture damage.

  • Humidity Control: The cabinet's humidity control range is 1%-60% RH with an over-humidity alarm that triggers when measured humidity exceeds the set value.
  • Nitrogen Flow: Nitrogen flow must be adjusted between 0 and 50 L/min to maintain the desired atmosphere.
  • Cabinet Sealing: Magnetic door sealing and tempered-glass viewing doors maintain the inert atmosphere; ensure doors are kept closed during normal use.
  • Shelf Loading: Stored items must be distributed evenly across the three adjustable perforated shelves to avoid obstruction of internal circulation.
  • Installation Environment: Install the cabinet on a stable indoor surface and verify level installation and door sealing before operation.

This procedure describes the steps to safely initialize and operate the 450L nitrogen cabinet for oxidation-sensitive material storage. Proper installation, gas supply verification, and humidity monitoring are critical to prevent material degradation.

Required Equipment: Nitrogen gas supply, Adjustable perforated shelves, Honeywell temperature and humidity sensor, Over-humidity alarm device

  1. Install the cabinet
    Install the cabinet on a stable indoor surface and verify level installation.
  2. Connect nitrogen supply
    Connect the nitrogen supply and adjust the flow rate to the desired level between 0 and 50 L/min.
  3. Distribute items evenly
    Distribute stored items evenly across the three adjustable shelves to ensure proper internal circulation.
  4. Monitor humidity
    Monitor the temperature and humidity display to confirm the humidity stays within the 1%-60% RH range.
  5. Configure alarm threshold
    Configure the over-humidity alarm threshold to trigger at the desired humidity level.
  6. Maintain door seal
    Keep the door closed during normal operation and inspect the magnetic sealing for integrity.

When should a stainless steel cabinet body be chosen over the anti-static coated steel body for the 450L anti-oxidation nitrogen cabinet?

The standard 1.2 mm galvanized steel cabinet with anti-static exterior coating is designed for electrostatic-control areas and ESD-sensitive material handling. For cleaner or more corrosion-conscious storage environments, a stainless steel cabinet-body upgrade is available. The anti-static coating provides ESD protection but may be less resistant to corrosive chemicals than stainless steel. Therefore, the choice depends on whether ESD protection or corrosion resistance is the priority in your storage application.

Can the 450L anti-oxidation nitrogen cabinet be integrated with an external nitrogen generator, and what are the compatibility requirements?

Yes, the cabinet supports a nitrogen generator configuration for on-site nitrogen supply. It provides 0-50 L/min nitrogen flow adjustment to match generator output. The cabinet requires a stable gas-supply condition before operation, and users must confirm utility conditions such as power and gas connections. The optional RS485 communication interface enables PC-side monitoring for integrated system management. Ensure the generator can sustain the desired flow rate and purity.

What installation conditions must be verified before operating the 450L anti-oxidation nitrogen cabinet to avoid performance degradation?

The cabinet must be installed on a stable indoor surface with level installation and proper door sealing. Verify stable gas-supply conditions and confirm power and gas connections before formal use. Distribute stored items evenly across the 3 adjustable shelves to avoid structural overloading. After delivery, inspect the cabinet for structural and sealing integrity, and protect the anti-static coating and magnetic seals during movement.

The 450L anti-static nitrogen cabinet provides controlled low-humidity storage for ESD-sensitive materials, using Honeywell sensing and adjustable nitrogen flow, but requires external nitrogen infrastructure and careful sealing maintenance.

Positive

  • Anti-static cabinet body for ESD safety: The 1.2 mm galvanized steel cabinet with anti-static exterior coating is suitable for electrostatic-control areas and ESD-sensitive material handling, reducing static discharge risks during storage.
  • Precise Honeywell humidity sensing: Honeywell temperature and humidity sensor delivers ±3% RH indication accuracy with only 0.3% annual drift, enabling reliable long-term monitoring of the low-humidity nitrogen atmosphere.

Trade-offs

  • Requires external nitrogen supply: Operation depends on a stable, regulated nitrogen gas source with flow adjustment up to 50 L/min, adding infrastructure and recurring consumable costs for the user.
  • Sealing and handling sensitivity: The magnetic door sealing and tempered-glass doors require careful handling during movement and installation; any seal degradation can compromise humidity control and nitrogen retention.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).