Four-Sided Programmable Climate Chamber, 360 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires a stable ambient environment with temperature not exceeding 26°C when operating at setpoints of 10°C or below. The unit must be connected to a AC220V 50Hz power supply and kept level on a stable surface during operation.
- Ambient Temperature Constraint: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C.
- Power Supply Requirement: The chamber must be connected to an AC220V 50Hz power supply with a rated input power of 1100 W.
- Leveling Requirement: The chamber must be placed on a level surface to ensure proper operation and stability.
- Transport Orientation Requirement: The unit must be kept upright during unloading and positioning to prevent damage.
- Performance Reference Conditions: Performance data are measured under no-load conditions at 20°C ambient temperature and 50%RH ambient humidity.
Position the chamber on a level surface and maintain stable ambient conditions. Unpack the unit keeping it upright, then confirm the control package and ensure ambient temperature limits are observed.
- Position the chamber
Position the chamber on a level surface in the intended installation area. - Maintain stable ambient conditions
Maintain stable ambient conditions within the recommended temperature range during operation. - Confirm control package
Confirm the chosen control and accessory package before installation. - Keep unit upright
Keep the unit upright during unloading and positioning to avoid internal damage. - Check ambient temperature limit
Ensure ambient temperature does not exceed 26°C when the set temperature is 10°C or below.
Why does the temperature control range differ between no-light mode and illuminated mode?
The illuminated mode has a higher minimum temperature because the four-sided lighting generates heat, raising the lower limit from 5°C to 10°C. The chamber specifications state a no-light range of 5 to 60°C and an illuminated range of 10 to 60°C, reflecting this thermal contribution from the lighting system.
What ambient temperature conditions are required when operating the chamber at set temperatures of 10°C or below?
When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C. This installation constraint, stated in the product specifications, ensures the chamber can maintain the low set point without being overwhelmed by external heat, which is critical for labs in warm environments or with limited climate control.
What power supply and input power are required for the Atomfair AF-QHX360F climate chamber?
The chamber requires an AC220V 50Hz power supply with an input power of 1100 W. This information is essential for electrical planning, ensuring the circuit can handle the load and that the laboratory's power infrastructure is compatible with the chamber's requirements.
The AF-QHX360F four-sided programmable climate chamber provides 360 L of conditioned space with four-face illumination up to 18,000 lux, programmable temperature/light/humidity/time control, and stainless-steel construction; however, its humidity band is limited to 50–90%RH with ±8%RH deviation, and low-temperature operation at ≤10°C requires ambient temperature ≤26°C.
Positive
- Four-sided illumination to 18,000 lux: The chamber delivers illumination from four faces with six selectable levels up to 18,000 lux, providing stronger and more even light exposure for plant-growth, photoperiod, and photoresponse experiments.
- Programmable multi-parameter climate control: An LCD microcomputer controller coordinates temperature, light, humidity, and time in programmable multi-step cycles, enabling repeatable cultivation, conditioning, and moisture-controlled biological workflows.
Trade-offs
- Ambient temperature limit at low setpoints: When the set temperature is 10°C or below, the surrounding ambient temperature must not exceed 26°C; performance data are based on no-load conditions at 20°C and 50%RH ambient humidity.
- Humidity range and deviation constraints: Humidity control is limited to 50–90%RH with a stated deviation of ±8%RH, so applications requiring lower humidity or tighter moisture tolerance would need additional dehumidification or a different chamber class.